Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 3: Segregated Grout with Elevated Sulfate and Vestigial Chloride Content
Source abstract
Abstract
Severe corrosion of post-tensioned (PT) tendons with pre-packaged thixotropic grout was documented in Florida bridges after less than 8 years of service. In those bridges, corrosion of steel tendon components was associated with deficient grout characterized by high moisture content, high sulfate levels, low chloride levels, and no indication of carbonation. Earlier research described in Parts 1 and 2 of this series of papers had emphasis on the role of sulfate ions in corrosion. However, at the time of observed corrosion of the bridge tendons in deficient grout, there were separate cases of bridges with similar pre-packaged grout materials but containing significant chloride ion contamination that exceeded typical acceptance limits. As a response to the potential risk to the bridge inventory, research was conducted to assess the risk associated with elevated chloride levels. Recommendations were made, but the proposed limits did not directly consider the effect of grout deficiencies such as that observed in the tendon failures in Florida. Therefore, there was interest to verify that the corrosion risk assessment of PT tendons by grout chloride concentration is adequate for adverse grout conditions such as due to segregation. In continuation of this series of papers on corrosion of post-tension strand in physically and chemically deficient grout, the work presented here sought to verify the role of elevated free sulfate ion concentrations in segregated grout containing low-level chlorides. Small and large scale laboratory specimens with geometries allowing for mix water volume displacement produced deficient grout. Physical and chemical deficiencies in segregated grout reduced the extent of chloride binding. Corrosion activity developed in grout with elevated sulfate concentrations. However, there were synergistic effects to reduce corrosion resistance for grouts with the combined presence of sulfate and chloride ions. It was shown that corrosion currents increased for steel in deficient grouts with elevated sulfate levels with the presence of low-level chloride ions (below conventional chloride threshold values). It was therefore evident that the assessment of corrosion susceptibility in deficient grout by chloride values alone is insufficient as sulfate ion presence and grout characteristics are also important.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
*Florida International University, Dept. of Civil and Environmental Engineering, 10555 W. Flagler St., Miami, FL 33174.
**State Materials Office, Florida Department of Transportation, 5007 N.E. 39th Avenue, Gainesville, FL 32609.
References (37)
Show source-provided references
1. “Corrosion Development of PT Tendons with Deficient Grout: Corrosion Failure in Ringling Causeway Bridge,”
2. “Corrosion Failure of Post-Tensioned Tendons in Presence of Deficient Grout,”
3. “Material and Corrosion Evaluation of Deficient PT Grout with Enhanced Sulfate Concentrations,”
4. “Corrosion of PT Tendons in Deficient Grout in Presence of Enhanced Sulfate and Chloride Concentration,”
5. “Corrosion of Post-Tensioned Tendons with Deficient Grout,”
6. Krishna Vigneshwaran · Corrosion · 2018 · 74 · 36210.5006/2541 ↗
7. Permeh · Corrosion · 2018 · 74 · 45710.5006/2568 ↗
8. “An FHWA Special Study: Post-Tensioning Tendon Grout Chloride Thresholds,”
9. “Guidelines for Sampling, Assessing, and Restoring Defective Grout in Prestressed Concrete Bridge Post-Tensioning Ducts,”
10. “Grout Testing and Analysis,”
11. “Corrosion of Metals in Concrete (ACI 222R-96)”
12. “Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary (ACI 318R-02)”
13. Angst · Cement Concrete Res. · 2009 · 39 · 112210.1016/j.cemconres.2009.08.006 ↗
14. “Specification for Grouting of Post-Tensioned Structures”
15. “Literature Review of Chloride Threshold Values for Grouted Post-Tensioned Tendons,”
16. “The Influence of Chlorides and Sulphates on Durability,”
17. Al-Amoudi · Cement Concrete Res. · 1993 · 23 · 13910.1016/0008-8846(93)90144-X ↗
18. Hussain · Cement Concrete Res. · 1994 · 24 · 810.1016/0008-8846(94)90078-7 ↗
19. Saleem · Constr. Build. Mater. · 1996 · 10 · 20910.1016/0950-0618(95)00078-X ↗
20. Dehwah · Cement Concrete Comp. · 2002 · 24 · 1710.1016/S0958-9465(01)00023-3 ↗
21. Dehwah · Cement Concrete Comp. · 2003 · 25 · 51310.1016/S0958-9465(02)00091-4 ↗
22. “Simulation of Prepackaged Grout Bleed Under Field Conditions,”
23. “Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying”
24. “Determining Chloride and Sulfate Contents in Soil,”
25. “Florida Method of Test for Determining Low-Levels of Chloride in Concrete and Raw Materials”
26. “Corrosion of the Strand-Anchorage System in Post-Tensioned Grouted Assemblies,”
27. “Durability Concept; Pore Structure and Transport Processes,”10.1016/B978-075065686-3/50255-X ↗
28. Page · Mater. Constr. · 1983 · 16 · 1910.1007/BF02474863 ↗
29. “HETEK, Chloride Penetration into Concrete, State-of-the-Art, Transport Processes, Corrosion Initiation, Test Methods and Prediction Models,”
30. Thomas · Cement Concrete Res. · 2012 · 42 · 110.1016/j.cemconres.2011.01.001 ↗
31. Hussain · Cement Concrete Res. · 1991 · 21 · 103510.1016/0008-8846(91)90064-O ↗
32. “Chloride Binding in Cement Pastes in Equilibrium with Synthetic Pore Solution,”
33. Tang · Cement Concrete Res. · 1993 · 23 · 24710.1016/0008-8846(93)90089-R ↗
34. Cornell · 2003 · 110.1002/3527602097 ↗
35. Jones · 1996
36. “Action: Elevated Chloride Levels in SikaGrout® 300 PT Cementitious Grout,”
37. “Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete”