Suitability of Assessment Methods for Identifying Active and Passive Zones in Reinforced Concrete
Source abstract
Abstract
The ability of various electrochemical techniques to differentiate between areas of reinforcing steel (rebar) with high and low corrosion activity and to define the boundary between such areas was studied. These techniques are based on determining the corrosion potential (Ecorr), the galvanic current between an external stainless steel (SS) sensor and the bar (Ig), the apparent polarization resistance (Rpap), or the polarization resistance (Rp) under electric confinement conditions. Values of Ecorr and Ig (the current flowing between a SS counter electrode [CE] and the rebars) were shown to distinguish active areas from passive ones very well when the areas were isolated electrically, but with difficulty when the areas were in electric contact, which is usually the case. Values of Rpap or icorr (both calculated using the Stern-Geary equation) were shown to define areas of high corrosion rates in a structure where passivity prevailed much better. However, excessive icorr values were estimated because the polarized area of the rebar (especially with passive rebars) was much greater than the CE area. Finally, the confinement of signal distribution permitted definition of the exact boundary between active and passive areas, regardless of whether they were isolated or interconnected. In addition, icorr values obtained with this technique were shown to provide a reliable quantitative index of the damage rate in reinforced concrete structures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
*Centro Nacional de Investigaciones Metallurgicas del Consejo Superior de Investigaciones Científicas, Av. Gregorio del Amo, No. 8, Madrid, 28040, Spain.
**Universidad Nacional Autónoma de México, Facultád de Química, Edificio D, México, 04510, DF.
***Instituto de Ciencias de la Construcción Eduardo Torroja, (ICCET), Serrano Galvache, s/n, Madrid, 28033, Spain.
References (15)
Show source-provided references
1. Stern · J. Electrochem. Soc. · 1957 · 104 · 5610.1149/1.2428496 ↗
2. Stern · Proc. ASTM · 1959 · 59 · 1,280
3. Feliu · Corrosion · 1990 · 46 · 1,01510.5006/1.3585049 ↗
4. Feliu · ACI Mater. J. · 1990 · 87 · 457
5. Application of Electrochemical Impedance Techniques to Estimate Corrosion Damage to Reinforcing Bars in Concrete
6. Feliu · Corrosion · 1988 · 44 · 10510.5006/1.3584943 ↗
7. Feliu · Corros. Sci. · 1989 · 29 · 10510.1016/0010-938X(89)90083-8 ↗
8. González · Mater. Const. · 1991 · 24 · 34610.1007/BF02472067 ↗
9. Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete
10. S. Feliu, J.A. González, V. Feliu, S. Feliu Jr., M.L. Escudero, I. Rz-Maribona, V. Ausin, C. Andrade, J.A. Bolaño, F. Jimenez, “Corrosion Detecting Probes for Use with a Corrosion-Rate Meter for Electrochemically Determining the Corrosion Rate of Reinforced Concrete Structures,” U.S. Patent No. 5,259,944 (1993).
11. Flis · Corrosion · 1993 · 47 · 60110.5006/1.3316091 ↗
12. Approximate Calculation of Service Life of Corroding Structures Using Polarization Resistance Measurements
13. Stratfull · Mater. Prot. · 1968 · 7 · 29
14. López · Cem. Concr. Res. · 1993 · 23 · 36810.1016/0008-8846(93)90102-F ↗
15. González · Corrosion · 1993 · 49 · 1,00410.5006/1.3316021 ↗