Pitting Corrosion of Inconel 600 in High Temperature Chloride Solution Under Controlled Hydrodynamic Conditions
Source abstract
Abstract
Pitting corrosion of mill annealed Inconel 600 in buffered 0.1 M NaCl solution was studied as a function of temperature (25 to 250 C) under well-defined hydrodynamic conditions (flow velocities from 0 to 158 cm/s) in an annular flow channel. Flow velocity had no significant effect on the breakdown potential over the entire temperature range studied, but some influence on the morphology of attack was noted. Temperature was found to be an important parameter, however, in determining the susceptibility of mill annealed Inconel 600 to localized attack in buffered 0.1 M NaCl solution.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Crystallization and Solubility Studies · Metallurgical Processes and Thermodynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
*P.O. Box 28, Rafsanjan, Iran.
**Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland.
***Formerly at Ohio State University, Columbus, Ohio. Now at SRI International, 333 Ravenswood, Menlo Park, CA 94025.
References (8)
Show source-provided references
1. Pitting at Elevated Temperatures
2. Beck · Corrosion · 1977 · 33 · 910.5006/0010-9312-33.1.9 ↗
3. deCastro · Corrosion · 1979 · 35 · 56010.5006/0010-9312-35.12.560 ↗
4. M. Karaminezhaad-Ranjbar , PhD Dissertation, Ohio State University, Columbus, Ohio, 1983.
5. Karaminezhaad-Ranjbar · Corrosion · 1985
6. Macdonald · J. Electrochem. Soc. · 1979 · 126 · 90810.1149/1.2129192 ↗
7. Lin · J. Electrochem. Soc. · 1981 · 128 · 119410.1149/1.2127592 ↗
8. Agrawal