Factors Affecting the Corrosion of Steel By Oil-Brine-Hydrogen Sulfide Mixtures
Source abstract
Abstract
A study was made of factors affecting the corrosion of steel by oil-brine-H2S mixtures in order to determine what conditions need to be met in setting up a screening test procedure for possible corrosion inhibitors. The initial rate of corrosion is dependent on the concentration of H2S. After the first day, the reaction becomes diffusion-controlled and is independent of H2S concentration over a wide range. At very high H2S concentrations, the corrosion rate actually decreases because of a change in the nature of the FeS coating formed on the steel. The presence of sodium chloride prevents the formation of a protective FeS coating on steel, and the corrosion rate increases with increasing salt concentration, reaching a maximum at about 1 percent salt. Above this concentration, the rate decreases, possibly due to inhibition by the salt itself. 3.4.8
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Material Properties and Failure Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
1General Electric Company, Hanford Atomic Products Operation, Richland, Washington.
2Department of Chemistry, The University of Texas, Austin, Texas.
References (2)
Show source-provided references
1. NACE Technical Unit Committee T-1K on Inhibitors for Oil and Gas Wells
2. Shannon · Corrosion · 1959 · 15 · 303t