Abstract
Localized corrosion constitutes a major concern in medical devices made of stainless steel. The conventional approach to circumvent such a problem is to convert the surface polycrystalline microstructure of the native oxide layer to an amorphous oxide layer, a few micrometers thick. This process cannot, however, be used for devices such as stents that undergo plastic deformation during their implantation, especially those used in vascular surgery for the treatment of cardiac, neurological, and peripheral vessels. This work explores the feasibility of producing a nano-thick plastic-deformation resistant amorphous oxide layer by plasma-based surface modifications. By varying the plasma process parameters, oxide layers with different features were produced and their properties were investigated before and after clinically-relevant plastic deformation. These properties and the related corrosion mechanisms were mainly evaluated using the electrochemical methods of open-circuit potential, cyclic potentiodynamic polarization, and electrochemical impedance spectroscopy. Results showed that, under optimal conditions, the resistance to corrosion and to the permeation of ions in a phosphate buffered saline, even after deformation, was significantly enhanced.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
*Laboratory for Biomaterials and Bioengineering, CRC-I, Department of Mining, Metallurgical and Materials Engineering, CHU de Québec Research Center, Laval University, Pavillon Pouliot, 1065 avenue de la Médecine, Québec, QC, Canada, G1V 0A6.
**CHU Research Center of Quebec, St. François d’Assise Hospital, 10 rue de l’Espinay, Québec, QC, Canada, G1L3L5.
References (54)
Show source-provided references
1. Migliavacca · J. Biomech. · 2002 · 35 · 80310.1016/S0021-9290(02)00033-7 ↗
2. Nazneen · J. Biomed. Mater. Res. B. · 2012 · 100B · 198910.1002/jbm.b.32772 ↗
3. Bowen · Adv. Healthcare Mater. · 2016 · 5 · 112110.1002/adhm.201501019 ↗
4. Everett · Ann. Biomed. Eng. · 2016 · 44 · 39110.1007/s10439-015-1476-3 ↗
5. Manivasagam · Recent Patents Corros. Sci. · 2010 · 2 · 4010.2174/1877610801002010040 ↗
6. “Metallic Biomaterials,”
7. Touzin · Mater. Sci. Forum. · 2010 · 638-642 · 1010.4028/www.scientific.net/MSF.638-642.10 ↗
8. Eric Jones · J. Biomed. Mater. Res. B. · 2014 · 102 · 136310.1002/jbm.b.33115 ↗
9. Grundmeier · Vakuum in Forschung und Praxis · 2006 · 18 · 3210.1002/vipr.200600282 ↗
10. Mazumder · J. Biomater. Sci. Polym. Ed. · 2003 · 14 · 135110.1163/156856203322599699 ↗
11. Touzin · Surf. Coat. Technol. · 2008 · 202 · 488410.1016/j.surfcoat.2008.04.088 ↗
12. Holvoet · Materials · 2010 · 3 · 151510.3390/ma3031515 ↗
13. Lewis · ACS Appl. Mater. Inter. · 2011 · 3 · 232310.1021/am200245d ↗
14. McBee · Electrochim. Acta · 1972 · 17 · 133710.1016/0013-4686(72)80079-3 ↗
15. Hedberg · Biointerphases · 2016 · 11 · 01890110.1116/1.4934628 ↗
16. “Drug Delivery Coatings for Coronary Stents,”10.1002/9781119308713.ch3 ↗
17. “Serum Chloride,”
18. Shih · J. Biomed. Mater. Res. A · 2007 · 80A · 86110.1002/jbm.a.30915 ↗
19. “Study on Corrosion Behaviour of AISI 316L Stainless Steel Treated with Air Cold Plasma,”
20. Suárez · Oxid. Met. · 2011 · 75 · 28110.1007/s11085-010-9231-5 ↗
21. “Oxidation of Nitinol and Its Effect on Corrosion Resistance,”
22. Acton · 2013
23. Cloutier · Adv. Mat. Res. · 2011 · 409 · 117
24. Dorri · Microsc. Microanal. · 2016 · 22 · 99710.1017/S1431927616011612 ↗
25. Haïdopoulos · Surf. Coat. Techol. · 2005 · 197 · 27810.1016/j.surfcoat.2004.10.113 ↗
26. Lewis · Plasma Process Polym. · 2010 · 7 · 310.1002/ppap.200900107 ↗
27. Lewis · Macromol. Mater. Eng. · 2009 · 294 · 1110.1002/mame.200800229 ↗
28. “Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices”
29. “Standard Reference Test Method for Making Potentiodynamic Anodic Polarization Measurements”
30. Park · Anal. Chem. · 2013 · 85 · 96410.1021/ac3025976 ↗
31. Lethabane · J. Mater. Res. Technol. · 2015 · 4 · 36710.1016/j.jmrt.2015.04.006 ↗
32. Ferreira · J. Electrochem. Soc. · 1985 · 132 · 76010.1149/1.2113954 ↗
33. Pan · J. Electrochem. Soc. · 2000 · 147 · 102110.1149/1.1393307 ↗
34. Silverman · J. Electrochem. Soc. · 1982 · 129 · 241910.1149/1.2123559 ↗
35. Lorang · J. Electrochem. Soc. · 1994 · 141 · 334710.1149/1.2059338 ↗
36. Musket · Appl. Phys. Lett. · 1986 · 49 · 37910.1063/1.97593 ↗
37. “X-Ray Photoelectron Spectroscopy Study of Radiofrequency-Sputtered Refractory-Compound—Steel Interfaces,”
38. Marcus · 2000 · 13110.1002/9783527619306.ch3 ↗
39. Von Fraunhofer · 1972
40. Tian · Mat. Sci. Eng. A · 2001 · 316 · 110.1016/S0921-5093(01)01245-X ↗
41. “Kinetics of Activation Polarization,”10.1007/978-3-319-24847-9_5 ↗
42. Machuca · Corros. Sci. · 2012 · 64 · 810.1016/j.corsci.2012.06.029 ↗
43. “Pit Morphology in Various Metals and Alloys,”
44. Natishan · J. Electrochem. Soc. · 2014 · 161 · C42110.1149/2.1011409jes ↗
45. Saadi · Corros. Sci. · 2016 · 111 · 72010.1016/j.corsci.2016.06.011 ↗
46. Burstein · Corros. Sci. · 1993 · 35 · 5710.1016/0010-938X(93)90133-2 ↗
47. “A New Technique of Corrosion Protection of Steel Using a Glow Discharge: 1 July 1993 to 30 June 1997, final report,”
48. Dieter · 1988 · 184
49. Hamdy · Int. J. Electrochem. Sci. · 2006 · 1 · 17110.1016/S1452-3981(23)17147-1 ↗
50. Stansbury · 200010.31399/asm.tb.fec.9781627083027 ↗
51. “Effect of Strain on the Corrosion Resistance of Nitinol and Stainless Steel in Simulated Physiological Environment,”
52. Lasia · 201410.1007/978-1-4614-8933-7 ↗
53. “Detection and Monitoring of Localized Corrosion by EIS,”
54. “Interpreting Electrochemical Impedance Spectra from Segmented Electrode Arrangements,”