Ablation Behavior of Materials Subjected To Missile Re-Entry Heat Flux Rates
Source abstract
Abstract
Hypersonic vehicles, during re-entry, are exposed to transient heating involving extremely high heat flux rates. These heat flux rates have been simulated in the laboratory with the plasma discharge from high-intensity, air-stabilized electric arcs of approximately 1000-kw power rating. This paper describes the behavior of samples of ten different materials tested in this facility, including four metals, three ceramics, two plastics, and graphite. Ablation rates, heat balances, and effective heats of ablation are presented. The influence of changes in the test environment upon material behavior is indicated. In the highest temperature test environment utilized, the plastic and graphite samples provided lower stagnation point weight loss rates during ablation than the metal and ceramic samples. 3.5.9
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vacuum and Plasma Arcs · Laser-induced spectroscopy and plasma · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. J. H. Bonin, C. F. Price, and D. E. Taylor. Determination of Factors Governing Selection and Application of Materials for Ablation Cooling of Hypervelocity Vehicles. Wright Air Development Center Technical Report 59-87, Part I, January 1959.
2. The Transient Temperature Distribution in Semi-infinite Solids with Melting
3. A Theoretical Study of Stagnation Point Ablation
4. Adams · ARS Journal · 1959 · 29 · 62510.2514/8.4852 ↗
5. J. H. Bonin, H. Halle, and C. F. Price. Determination of Factors Governing Selection and Application of Materials for Ablation Cooling of Hypervelocity Vehicles. Wright Air Development Center Technical Report 59-87, Part III, May 1959.