Effects of Polarization on Telephone Cable Buried Through a Salt Bed

Daniel R. Werner

Corrosion· Volume 9· Issue 7
Publisher page

Abstract

Cathodic protection has been applied to a copper jacketed cable in a salt lake bed about one mile wide in which the earth resistivity was apparently uniform at about 20 ohm-centimeters. Current of about one ampere flowed on the copper jacket into the low earth resistivity lake bed area from the higher earth resistivity areas on either side and was found to be sustained by polarization effects when the cathodic protection current was removed. The current loss on the copper jacket was found to be concentrated in an area about 720 feet wide, 360 feet each side of the point where the cathodic protection current had been drained from the copper jacket. The copper jacket to soil potential tested most negative to a copper sulfate half cell in the 720-foot area where the current loss was concentrated and was of the order of —1.0 to —1.1 volts. Permanent remedial measures will consist of installations of magnesium anodes distributed throughout the low earth resistivity area and insulating joints in the copper jacket at locations where large changes in the earth resistivity occur.