journal article·2013-01

Experimental study on dynamic behaviours of concrete after exposure to high temperatures up to 700 °C

J. S. Huo, Y. M. He, L. P. Xiao, B. S. Chen

Materials and Structures· Volume 46· Issue 1-2
Publisher page

Abstract

A Split Hopkinson pressure bar were used to experimentally study the dynamic behaviours of normal-strength concrete after exposure to elevated temperatures up to 700 °C. The dynamic strength and stress–strain relation curves of fire-damaged concrete were measured to unveil the effects of high temperature and strain rate on the dynamic behaviours of fire-damaged concrete. Test results showed that fire-damaged concrete still experienced remarkable strain rate effect and the dynamic stress versus strain relations of fire-damaged concrete were significantly different from those of concrete at room temperature. There was no obvious effect of temperature and strain rate on the shape of the ascending branches of normalized stress–strain relation curves of concrete after exposure to high temperatures. The tested results also showed that high temperature and strain rate had remarkable effect on the dynamic increase factor (DIF) for the fire-damaged concrete. The effect of high temperature on DIF of the fire-damaged concrete decreased as the temperature increased. The tested results can be a basis for assessing the impact resistance and anti-collapse resistance of fire-damaged concrete structures.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Engineering and Material Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Watstein D (1953) Effect of straining rate on the compressive strength and elastic properties of concrete. ACI J Proc 49(4):729–744
2. Goldsmith W, Polivka M, Yang T (1966) Dynamic behaviour of concrete. Exp Mech 6(2):65–7910.1007/BF02326224 ↗
3. Soroushian P, Choi KB, Alhamad A (1986) Dynamic constitutive behaviour of concrete. ACI J Proc 83(2):251–259
4. Bischoff PH, Perry SH (1991) Compressive behaviour of concrete at high strain rates. Mater Struct 24(4):425–45010.1007/BF02472016 ↗
5. Kolsky H (1949) An investigation of the mechanical properties of materials at very high rates of loading. Proc Phys Soc. Sect B 62(11):676–70010.1088/0370-1301/62/11/302 ↗
6. Gary G, Bailly P (1998) Behaviour of quasi-brittle material at high strain rate. Experiment and modeling. Eur J Mech-A/Solids 17(3):403–42010.1016/S0997-7538(98)80052-1 ↗
7. Li QM, Meng H (2003) About the dynamic strength enhancement of concrete-like materials in a split Hopkinson pressure bar test. Int J Solids Struct 40(2):343–36010.1016/S0020-7683(02)00526-7 ↗
8. Forquin P, Gatuingt F, Gary G (2007) A testing technique of confined compression for concrete at high rates of strain. Experimental Analysis of Nano and Engineering Material and Structures Proceedings of the 13th International Conference on Experimental Mechanics, Alexandroupolis, July 1–6, http://romanee.lmt.ens-cachan.fr/PDFs/FORQUIN.2007.1.pdf
9. Forquin P, Gary G, Gatuingt F (2008) A testing technique for concrete under confinement at high rates of strain. Int J Impact Eng 35(6):425–44610.1016/j.ijimpeng.2007.04.007 ↗
10. Liu CX, Li YL, Wu ZY et al (2011) Dynamic compression behaviour of heated concrete. Chin Civil Eng J 44(4):78–83 (in Chinese)
11. He YM, Huo JS, Xiao Y (2011) Experimental study on dynamic behavior of concrete at elevated temperatures. Adv Sci Lett 4(3):1128–113110.1166/asl.2011.1732 ↗
12. Huo JS, Zheng Q, Chen BS et al (2009) Tests on impact behaviour of micro-concrete-filled steel tubes at elevated temperatures up to 400 °C. Mater Struct 42(10):1325–133410.1617/s11527-008-9452-0 ↗
13. GB50204-2002 (2002) Code for acceptance of constructional quality of concrete structures. Standards Press of China, Beijing
14. Huo JS, Huang GW, Xiao Y (2009) Effects of sustained axial load and cooling phase on post-fire behaviour of concrete-filled steel tubular stub columns. J Constr Steel Res 65(8–9):1664–167610.1016/j.jcsr.2009.04.022 ↗
15. Lindholm US (1964) Some experiments with the split Hopkinson pressure bar. J Mech Phys Solids 12(5):317–33510.1016/0022-5096(64)90028-6 ↗
16. Chan YN, Peng GF, Anson M (1999) Residual strength and pore structure of high-strength concrete and normal strength concrete after exposure to high temperatures. Cement Concr Compos 21(1):23–2710.1016/S0958-9465(98)00034-1 ↗
17. Lie TT, Rowe TJ, Lin TD (1984) Residual strength of fire-exposed reinforced concrete columns. ACI Publ SP 92(2):153–174
18. Arioz O (2007) Effects of elevated temperatures on properties of concrete. Fire Saf J 42(8):516–52210.1016/j.firesaf.2007.01.003 ↗
19. Chang YF, Chen YH, Sheu MS et al (2006) Residual stress-strain relationship for concrete after exposure to high temperatures. Cem Concr Res 36(10):1999–200510.1016/j.cemconres.2006.05.029 ↗
20. Lee J, Xi YP, Willam K (2008) Properties of concrete after high-temperature heating and cooling. ACI Mater J 105(4):334–341
21. Thomas T (1993) CEB-FIP Model Code 1990, Design Code. Comité Euro-International du Béton, London
22. Georgali B, Tsakiridis PE (2005) Microstructures of fire-damaged concrete: a case study. Cement Concr Compos 27(2):255–25910.1016/j.cemconcomp.2004.02.022 ↗
23. Phan LT, Carino NJ (1998) Review of mechanical properties of HSC at elevated temperature. J Mater Civ Eng 10(1):58–6410.1061/(ASCE)0899-1561(1998)10:1(58) ↗
24. Gawin D, Majorana CE, Schrefer BA (1999) Numerical analysis of hygro-thermal behaviour and damage of concrete at high temperature. Mech Cohesive-Frict Mater 4(1):37–7410.1002/(SICI)1099-1484(199901)4:1<37::AID-CFM58>3.0.CO;2-S ↗