Quantitative evaluation method for cathodic protection polarisation coupon
Source abstract
Abstract
With the many advantages of instantaneous off measurement, the polarisation coupon has become increasingly popular in the true polarisation potential reading of different cathodic protection systems. As a general rule, polarisation coupons are installed close to the reference electrode to reduce the error in potential measurement. As a result, the error in the potential reading for close coupons is low. Still, the mentioned error has not been quantified due to the coupon's geometry, direction and non-linear polarisation behaviour complexity. In the present work, the IR-Drop error as a function of current density is extracted with generic calculation and simple assumptions, and the results are checked with three possible coupon-reference electrode arrangements. The proposed calculation could be used to extract the intrinsic error of polarisation coupons, regardless of their arrangement and coupon size. Moreover, it could be used to correct the measured potential and extract the true structure-to-soil potential.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrical Contact Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
CMP Group s.r.l., Casella, Italy
References (29)
Show source-provided references
1. NACE SP-0169. Control of external corrosion on underground for submerged metallic piping systems; 2013.
2. ISO 15589-1. Petroleum, petrochemical and natural gas industries – Cathodic protection of pipeline systems – Part 1: On-land pipelines; 2015.
3. Lazzari L · 2006
4. ISO 22426. Assessment of the effectiveness of cathodic protection based on coupon measurements; 2020.
5. EN 13509. Cathodic protection measurement techniques; 2003.
6. NACE TM-0497. Measurement techniques related to criteria for cathodic protection on underground or submerged metallic piping systems; 2018.
7. Lawson KM · 1998
8. Gilroy D. · 2017
9. Moghissi OC · 1997
10. Al-Mithin AW · 2012
11. Agel E · 2013
12. Dos Santos G · 2016
13. 10.5006/337910.5006/3379 ↗
14. NACE 35201. Technical report on the application and interpretation of data from external coupons used in the evaluation of cathodically protected metallic structures; 2001.
15. Nekoksa G. · 2001
16. Barlo TJ. · 1998
17. Nekoksa G. · 1998
18. Brenna A · La Metal Ital · 2020 · 11
19. Khan NA. · 2007
20. Yunovich M · 2002
21. Roche M · 2016
22. Larché N · 2016
23. Magnifico I · 2016
24. 10.1080/1478422X.2016.126209610.1080/1478422X.2016.1262096 ↗
25. NACE International. Cathodic Protection Technologist Course Manual, (2011).
26. 10.5006/1.328058210.5006/1.3280582 ↗
27. API 5L. Specification for line pipe, American Petroleum Institute (API), 1220 L St., N.W., Washington, DC 20005-4070; 2018.
28. Gummow RA. · Mater Performance · 1993 · 32 · 21
29. Gummow RA · 2016