Characterisation of corrosion properties of Ti–Nb–Cu alloy foam by electrochemical impedance spectroscopy method
Source abstract
Abstract
In the present study, highly porous Ti–Nb–Cu alloy foams were produced by a powder metallurgy method for biomedical implant (hard tissue) applications. Nb was added in order to stabilize the beta-Ti phase. Cu addition enhanced sinterability and reduced the sintering temperature of the alloy. Electrochemical corrosion behaviour of the Ti–Nb–Cu alloy specimens was examined by the electrochemical impedance spectroscopy method in an artificial saliva environment. Effects of porosity of the foam, Cu content of the alloy, pH and fluoride content of the artificial saliva solution on the electrochemical corrosion properties of the specimens were investigated. Mechanical properties of the specimens were also studied by compression tests.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Corrosion Behavior and Inhibition · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. 10.1016/B978-075067219-1/50004-010.1016/B978-075067219-1/50004-0 ↗
2. 10.1017/CBO978113987832610.1017/CBO9781139878326 ↗
3. Wenjuan N. · Mater. Sci. Eng. A · 2009 · 506 · 14810.1016/j.msea.2008.11.022 ↗
4. 10.1016/j.msec.2012.12.00410.1016/j.msec.2012.12.004 ↗
5. 10.1016/j.jbiomech.2004.09.02710.1016/j.jbiomech.2004.09.027 ↗
6. 10.1016/j.jallcom.2009.05.04810.1016/j.jallcom.2009.05.048 ↗
7. 10.1016/j.scriptamat.2012.01.02310.1016/j.scriptamat.2012.01.023 ↗
8. 10.1016/j.matdes.2010.11.04910.1016/j.matdes.2010.11.049 ↗
9. 10.1016/j.jallcom.2010.05.13410.1016/j.jallcom.2010.05.134 ↗
10. 10.1016/j.msea.2012.09.01210.1016/j.msea.2012.09.012 ↗
11. 10.1016/j.matchar.2011.04.01510.1016/j.matchar.2011.04.015 ↗
12. 10.1016/j.jallcom.2011.04.09010.1016/j.jallcom.2011.04.090 ↗
13. 10.1016/S1003-6326(11)60862-510.1016/S1003-6326(11)60862-5 ↗
14. 10.1016/j.elecom.2006.06.00410.1016/j.elecom.2006.06.004 ↗
15. 10.1002/maco.20080517310.1002/maco.200805173 ↗
16. 10.1016/j.electacta.2008.02.01110.1016/j.electacta.2008.02.011 ↗
17. 10.1179/1743278214Y.000000019210.1179/1743278214Y.0000000192 ↗
18. 10.1016/j.matdes.2011.03.04010.1016/j.matdes.2011.03.040 ↗
19. 10.2320/matertrans.M201129310.2320/matertrans.M2011293 ↗
20. 10.1002/jbm.b.3141210.1002/jbm.b.31412 ↗
21. 10.1016/S1044-5803(02)00320-010.1016/S1044-5803(02)00320-0 ↗
22. 10.1016/j.msec.2013.11.02810.1016/j.msec.2013.11.028 ↗
23. Albrektsson T. and Isidor F. ‘Consensus report of session IV’, in ‘Proceedings of the First European Workshop on periodontology’, (ed. Lang N. P. and Karring T. 365–369; 1994, London, Quintessence.
24. 10.1007/s00586010028210.1007/s005860100282 ↗
25. 10.1016/S0142-9612(00)00392-610.1016/S0142-9612(00)00392-6 ↗
26. 10.1016/j.electacta.2012.06.02910.1016/j.electacta.2012.06.029 ↗
27. 10.1016/j.msec.2010.12.01010.1016/j.msec.2010.12.010 ↗
28. 10.1007/s10856-012-4591-910.1007/s10856-012-4591-9 ↗
29. 10.1016/j.electacta.2007.10.06010.1016/j.electacta.2007.10.060 ↗
30. 10.1016/j.corsci.2009.04.01310.1016/j.corsci.2009.04.013 ↗
31. 10.1007/s10856-010-4147-910.1007/s10856-010-4147-9 ↗
32. 10.1007/s11665-008-9198-410.1007/s11665-008-9198-4 ↗
33. 10.1007/s10800-010-0243-210.1007/s10800-010-0243-2 ↗
34. 10.1016/j.msec.2004.11.00410.1016/j.msec.2004.11.004 ↗
35. 10.1016/j.corsci.2010.01.00810.1016/j.corsci.2010.01.008 ↗
36. 10.1016/j.electacta.2013.04.10510.1016/j.electacta.2013.04.105 ↗
37. 10.1016/j.electacta.2009.09.01610.1016/j.electacta.2009.09.016 ↗
38. 10.1007/s10800-006-9283-z10.1007/s10800-006-9283-z ↗
39. 10.1016/j.corsci.2013.03.00710.1016/j.corsci.2013.03.007 ↗
40. 10.1016/j.corsci.2007.10.00110.1016/j.corsci.2007.10.001 ↗
41. 10.1016/j.surfcoat.2013.05.04110.1016/j.surfcoat.2013.05.041 ↗
42. 10.4012/dmj.20.30510.4012/dmj.20.305 ↗