Durability performance of rebar embedded in chloride admixed blended cement concretes
Source abstract
Abstract
In concrete structures, permeation of chloride ions either through the pores or by visible/microcracks or contamination of chloride along with the fine and coarse aggregates increase the availability of chloride ion at the rebar level. The reduction of OH− ions by pozzolanic reaction and by replacement of cement by mineral admixtures may reduce the chloride ion tolerable limit of rebar in blended cement concretes. In the present investigation, the corrosion rate of rebar in 0·5 and 1% chloride admixed concrete was assessed periodically up to a period of 1765 days using electrochemical impedance spectroscopic technique. Ordinary Portland cement (OPC), pulverised fuel ash cement (PFAC) and blast furnace slag cement (BFSC) were evaluated in 20, 30 and 40 MPa concretes. The high Rp value of rebar obtained in blended cements indicates that the additional calcium hydrates maintains the pH and also contributes significantly to the inhibitive effects at the steel/concrete interface thus maintaining the passivity of rebar. The results reveal that the high chloride ion complexing ability and microstructural changes by the formation of additional calcium hydrates in the PFAC and BFSC concrete matrix enhancing the corrosion resistance of rebar by a factor of five times than that of OPC concrete in 0% chloride added concrete and three times in 1% chloride contaminated concrete. The reduction of OH− ions did not decrease the chloride tolerable limit of rebar in PFAC and BFSC concrete; moreover they had 1·4 times higher chloride tolerance than that of OPC concrete.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. 10.1680/macr.1989.41.149.20510.1680/macr.1989.41.149.205 ↗
2. Pruckner F: ‘Corrosion and protection of reinforcement in concrete: measurements and interpretation’, PhD thesis, University of Vienna, Vienna, Austria, 2001.
3. 10.1016/0008-8846(96)00035-X10.1016/0008-8846(96)00035-X ↗
4. 10.1061/(ASCE)0899-1561(1990)2:1(24)10.1061/(ASCE)0899-1561(1990)2:1(24) ↗
5. 10.1038/297109a010.1038/297109a0 ↗
6. 10.1179/00070599910150093210.1179/000705999101500932 ↗
7. Glass GK, Buenfeld NR: Prog. Struct. Eng. Mater . 2000, 2, 448–455.
8. 10.1016/0008-8846(81)90110-110.1016/0008-8846(81)90110-1 ↗
9. Berke NS, Scali MJ, Regan JC: Proc. 2nd CANMET/ACI Int. Conf. on ‘Durability of concrete’, vol. 1, 393; 1991, Montreal, ACI.
10. 10.1016/0008-8846(91)90177-J10.1016/0008-8846(91)90177-J ↗
11. Gu P · ACI Mater. J. · 2000 · 97 · 254
12. 10.1061/(ASCE)0899-1561(1994)6:2(223)10.1061/(ASCE)0899-1561(1994)6:2(223) ↗
13. Glass GK · Corros. Sci. · 2000 · 4210.1016/S0010-938X(00)00008-1 ↗
14. 10.1680/macr.1993.45.162.6310.1680/macr.1993.45.162.63 ↗
15. ‘Specification for 43 grade ordinary Portland cement’, BIS standards no. IS 8112, BIS, New Delhi, India, 1989.
16. ‘Specification for Portland pozzolana cement (fly ash based) ’, BIS standards no. IS 1489 (Part 1), BIS, New Delhi, India, 1991.
17. ‘Specification for Portland slag cement’, BIS standards no. IS 455, BIS, New Delhi, India, 1989.
18. ‘Specification for high strength deformed steel bars and wires for concrete reinforcement’, BIS standard no. IS 1786, BIS, New Delhi, India, 1985.
19. ‘Standard practice for the preparation of substitute ocean water’, D1141-98, ASTM, Philadelphia, PA, USA.
20. 10.1016/S0010-938X(98)00036-510.1016/S0010-938X(98)00036-5 ↗
21. 10.1002/maco.1978029080410.1002/maco.19780290804 ↗
22. 10.1149/1.242849610.1149/1.2428496 ↗
23. ‘Standard practice for preparing cleaning and evaluating corrosion test specimens’, G1–13, ASTM, Philadelphia, PA, USA, 2009.
24. Muralidharan S · Build. Environ. · 2005 · 4010.1016/j.buildenv.2004.10.005 ↗
25. ASTM ‘Standard test method for half-cell potentials of uncoated reinforcing steel in concrete’, C876-80, ASTM, Philadelphia, PA, USA, 2000.
26. Bartolo-Perez B, Pena JL, Salas FH, Wheat HG, Hermandez-Duqae G: Corros. Rev. 2000, 1825–1833.
27. Monticelli C · Cem. Concr. Res. · 2000 · 44
28. 10.1023/A:101650771302210.1023/A:1016507713022 ↗
29. Gu P, Ellioh S, Hristora R, Benudoin JJ, Broussean R, Baldock B: ACI Mater. J. 1997, 94: 385–395.
30. 10.1179/00070598179827500210.1179/000705981798275002 ↗
31. Wenger F · Electrochim. Acta · 1990 · 3
32. 10.1179/00070599279826877410.1179/000705992798268774 ↗
33. Glass GK · Corros. Sci. · 2000 · 4210.1016/S0010-938X(00)00040-8 ↗
34. 10.1016/S0008-8846(99)00127-110.1016/S0008-8846(99)00127-1 ↗
35. 10.1016/S0010-938X(00)00050-010.1016/S0010-938X(00)00050-0 ↗
36. 10.1016/S0040-6031(03)00286-710.1016/S0040-6031(03)00286-7 ↗
37. CEB working party V/4·1, ‘Strategies for testing and assessment of concrete structures by reinforcement corrosion (draft) ’, BBRI- CSTC-WTC3-1997.
38. 10.1016/S0008-8846(96)85009-510.1016/S0008-8846(96)85009-5 ↗
39. 10.1016/0008-8846(93)90153-Z10.1016/0008-8846(93)90153-Z ↗
40. 10.1016/0008-8846(93)90143-W10.1016/0008-8846(93)90143-W ↗
41. Schiessel P, Raupach M:in‘Corrosion of reinforcement in concrete’(, Page CL, et al.), 49; 1990, London, Elsevier.