journal article·2011-04

Further studies of in situ corrosion testing of miniature copper–cast iron nuclear waste canisters

N Smart, A Rance, B Reddy, S Lydmark, K Pedersen, C Lilja

Publisher page

Abstract

To ensure the safe disposal of spent fuel in Sweden, SKB is planning to use the copper–iron canister in a granitic deep geological repository, surrounded by a compacted bentonite engineered barrier. In order to develop a deeper understanding of the internal corrosion behaviour of the design should a leak occur in the outer copper canister, a set of model canisters was set up in the Äspö underground laboratory in contact with bentonite with a range of densities. The environmental conditions and electrochemical corrosion behaviour were monitored using a range of techniques. Water analysis and electrochemical measurements indicated an increase in the corrosion rate of both iron and copper in contact with low density bentonite, and of iron only in experiments with no bentonite present. This behaviour may be attributable to microbial activity. The measured corrosion rate depends on the technique used and it will be necessary to confirm the measurements by removal and examination of weight loss coupons.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Concrete and Cement Materials Research · Groundwater flow and contamination studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (4)

Show source-provided references
1. Smart NR · 2003 · 280
2. Smart NR, Rance AP: ‘Miniature canister corrosion experiment – results of operations to May 2008’, SKB report TR-09-20, SKB, Stockholm, Sweden, 2009.
3. Andersson C.G: ‘Development of fabrication technology for copper canisters with cast inserts’, SKB report TR-02-07, SKB, Stockholm, Sweden, 2002.
4. 10.1111/j.1574-6968.1996.tb08367.x10.1111/j.1574-6968.1996.tb08367.x ↗