Effect of temperature on corrosion parameters and apparent activation energy measured by embedded sensors in pilot container in El Cabril repository
Source abstract
Abstract
In order to study the real on-site aging of concrete and the potential corrosion risk for the reinforcements, Enresa has undertaken a monitoring programme in collaboration with Institute of Construction Science ‘Eduardo Torroja’ (IETcc) by permanently monitoring a pilot nuclear waste container through the installation of sensors. The pilot container of medium and low radioactive waste is buried near the real large concrete cells and has been monitored from 1994. The evolution from 1995 of corrosion parameters (corrosion rate, corrosion potential, electrical resistivity, concrete strains, oxygen availability) obtained is commented in the paper. The results indicate that the parameters evolve with time and the temperature is a very relevant variable influencing the measurements. An attempt to model the effect of temperature has been made by calculating the ‘apparent activation energies’ for the case of the electrical resistivity. Two clear regimes or slopes were found, one below and the other above 20°C, which have been attributed to a change in the state of the water from liquid to vapour although it has not been confirmed. The fact is that the resistivity increase is more pronounced above 20°C than below.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. 10.1016/j.jnucmat.2006.06.01510.1016/j.jnucmat.2006.06.015 ↗
2. Andrade C, Rodriguez J, Jimenez F, Palacio J, Zuloaga P: ‘Embedded sensors for concrete structures instrumentation’, Proc. Workshop on ‘Instrumentation and monitoring of concrete structures’, March 2000, Brussels, BelgiumNEA/CSNI/R. 2000, 15, 249–256.
3. 10.1617/1395210.1617/13952 ↗
4. 10.1002/maco.1978029080410.1002/maco.19780290804 ↗
5. 10.1007/BF0248165610.1007/BF02481656 ↗
6. 10.1680/istbu.1992.2150210.1680/istbu.1992.21502 ↗
7. Gjørv OE · Mater. Perform. · 1983 · 25 · 39
8. Clifton J: ‘Methods for predicting remaining life of concrete in structures’, Report NISTIR 4954 NIST, US Department of Commerce, Washington, DC, USA, 1992.
9. Rodríguez J, Ortega LM, Casal J, Díez JM: ‘Corrosion of reinforcement and service life of concrete structures’, Proc. Conf. on ‘Durability of building materials and components’, (ed. , Sjöstrom C, ed), Vol. I, 117–126; 1996, Stockholm, E&FN Spon Publishers.10.4324/9781315025025-13 ↗
10. Zuloaga P: ‘Spent nuclear fuel management in Spain’, Proc. Int. Conf. on ‘Spent fuel from nuclear power reactors’, Vienna, Austria, May–June 2010, IAEA, 623-643.
11. Brameshuber W: ‘Monitoring of the water distribution in concrete structures’, Proc. 2nd Int. RILEM Workshop on ‘Concrete durability and service life planning’, Haifa, Israel, September 2009, RILEM, 515-519.
12. Schiessl P, Raupach M: ‘Influence of temperature on the corrosion rate of steel in concrete containing chlorides’, Proc. 1st Int. Conf. on ‘Reinforced concrete materials in hot climates’, El-Ain, United Arab Emirates, April 1994, United Arab Emirates University, 537–549.