Corrosion of steel gas pipe under stray current from electro-osmotic pulse water-proof system
Source abstract
Abstract
The electro-osmotic pulse (EOP) systems are widely used for damp-proofing the basements of buildings. However, the cathode of EOP systems will produce stray current interference, posing risks of electrochemical corrosion to the buried steel pipe. This paper introduces a series of on-site tests and numerical simulations conducted in a townhouse alley equipped with EOP systems. The corrosion risk produced by EOP was evaluated and corrosion mitigation measurements were discussed. The results show that the EOP system produces 1 Hz pulse dynamic direct current in the soil, resulting in the average ground potential of gas pipes and the building steel pipe will rise from -0.7 to +1-4V. The shorter the distance, the stronger the interference. Metal shielding nets and sacrificial anode were simulated and proposed to mitigate pipe corrosion. The findings of this study can serve as a reference for the safe use of EOP systems and gas pipe anti-corrosion protection.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrokinetic Soil Remediation Techniques · Geophysical Methods and Applications · Geotechnical Engineering and Underground Structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical Engineering, Tongji University, Shanghai, People’s Republic of China
Funding
National Natural Science Foundation of China
References (30)
Show source-provided references
1. Goel RK · 2012
2. 10.1016/j.tust.2015.11.02410.1016/j.tust.2015.11.024 ↗
3. Grachev A. · 2021
4. 10.1016/j.conbuildmat.2015.10.04810.1016/j.conbuildmat.2015.10.048 ↗
5. Hock V · Mater Perform · 2005 · 44 · 42
6. Xintec G. How to deal with dampness in the basement? What are the inherent advantages of an electrical infiltration waterproofing system? 2018. Available from: https://zhuanlan.zhihu.com/p/32572454
7. Mcinerney MK · 2006
8. 10.1016/B978-0-12-817048-9.00004-410.1016/B978-0-12-817048-9.00004-4 ↗
9. Zhu JM · Adv Mat Res · 2011 · 255 · 752
10. 10.1007/s10311-018-0731-x10.1007/s10311-018-0731-x ↗
11. 10.3390/met805033410.3390/met8050334 ↗
12. 10.1016/j.ijpvp.2021.10432910.1016/j.ijpvp.2021.104329 ↗
13. 10.1179/1743278215Y.000000001310.1179/1743278215Y.0000000013 ↗
14. 10.5006/335510.5006/3355 ↗
15. 10.1016/j.ijpvp.2016.11.00710.1016/j.ijpvp.2016.11.007 ↗
16. 10.1515/corrrev-2017-000910.1515/corrrev-2017-0009 ↗
17. 10.1016/j.jngse.2015.06.04410.1016/j.jngse.2015.06.044 ↗
18. 10.3390/en1204074610.3390/en12040746 ↗
19. 10.1016/j.conbuildmat.2017.09.11410.1016/j.conbuildmat.2017.09.114 ↗
20. Yu Z · IEEE Trans Appl Supercond · 2019 · 29 · 1
21. 10.5006/307410.5006/3074 ↗
22. 10.1080/1478422X.2018.143673610.1080/1478422X.2018.1436736 ↗
23. 10.1080/1478422X.2020.177258710.1080/1478422X.2020.1772587 ↗
24. Wang A · IEEE Trans Power Deliv · 2020 · 99 · 1
25. Feng J · Int J Electrochem Sci · 2021 · 16 · 110.20964/2021.06.02 ↗
26. EN B. · 2003
27. Merten BJE. Embedded reference electrodes for corrosion potential monitoring, electrochemical characterization, and controlled-potential cathodic protection. Ann Arbor (MI): North Dakota State University; 2012. p. 226.
28. 10.1016/j.ijpvp.2021.10450910.1016/j.ijpvp.2021.104509 ↗
29. 10.1080/1478422X.2017.130565110.1080/1478422X.2017.1305651 ↗
30. En B. · 2004