Influence of activated carbon on crevice corrosion in adsorption tower of advanced liquid processing system
Source abstract
Abstract
The adsorption tower made of type 316L stainless steel (SS) in Multi-nuclide Removal Equipment (Advanced Liquid Processing System) which uses Ag-impregnated activated carbon (Ag AC) as an adsorbent experienced crevice corrosion. The influence of Ag AC on the crevice corrosion susceptibility and Esp of 316L SS was investigated by performing electrochemical experiments. Crevice corrosion was observed in the specimen in contact with the Ag AC. On the other hand, there was no crevice corrosion without the Ag AC in both pH 7.4 and pH 12 solutions. Clear ennoblement of spontaneous potential (Esp) by in contact with activated carbon was observed and that was clearly higher than the repassivation potential for crevice corrosion (ER,CREV). Thus, the presence of the AC notably increased Esp of 316L SS and this resulted in increased crevice corrosion susceptibility by the galvanic effect. This paper is part of a supplementary issue from the 17th Asia-Pacific Corrosion Control Conference (APCCC-17).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Industrial Gas Emission Control · Membrane-based Ion Separation Techniques · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Engineering, Tohoku University, Sendai, Japan
References (5)
Show source-provided references
1. Tatsumoto H, Abe I. Kasseitan no ouyou gijutsu [Applied technology of activated carbon]. Tokyo: Techno System; 2000. p. 17–18. Japanese.
2. Tsujikawa S · Boshoku-Gijutsu (Presently Zairyo-to-Kankyo) · 1980 · 29 · 37
3. Tsujikawa S · Boshoku-Gijutsu (Presently Zairyo-to-Kankyo) · 1983 · 32 · 149
4. 10.5006/0010-9312-15.9.2310.5006/0010-9312-15.9.23 ↗
5. 10.2355/tetsutohagane1955.65.13_195310.2355/tetsutohagane1955.65.13_1953 ↗