journal article·2026-05

Simulation of heterogeneity's effect on outer bottom plate potential of metal storage tanks

Jie Kou, Linjun Wu, Zhe Ren, Wei Li

Publisher page

Abstract

Metal storage tanks often encounter corrosion-related incidents. Along with the development of tank integrity management, their corrosion protection has drawn more attention. Impressed current cathodic protection is deemed the most effective for ensuring tank safety. This study uses COMSOL's finite-element method to create a cathodic protection model for a storage tank's external bottom plate, analysing the influence of heterogeneous factors on its potential distribution. Results show that the best protection occurs when the auxiliary anode is in high-resistance soil and the bottom plate in low-resistance soil. The cathodic protection potential of the bottom plate shifts positively with anode operation time, related to anode wear. Tank diameter and spacing affect protection, with the best outcome when spacing equals diameter. The research benefits the theory and engineering application.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spacecraft and Cryogenic Technologies · Cyclone Separators and Fluid Dynamics · Rocket and propulsion systems research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of pipeline and civil engineering in China University of Petroleum (East China), Qingdao, China

Sinopec Yantai Longkou LNG Co., Ltd, Yantai City, China

Funding

National Natural Science Foundation of China

References (34)

Show source-provided references
1. Yanxia D. Study on the potential distribution of cathodic protection on the outer side of metal tank bottoms. Shandong: China University of Petroleum (East China), 2007. DOI:https://doi.org/10.7666/d.y1215058.
2. Chao G, Fan W, Long Y, et al. Common problems in designing cathodic protection systems for the underside of tank bottoms. Oil & Gas Storage Transp 2012; 31: 833–836.
3. 10.1016/j.conbuildmat.2013.04.01010.1016/j.conbuildmat.2013.04.010 ↗
4. 10.1002/maco.20100570710.1002/maco.201005707 ↗
5. 10.1002/maco.20221368410.1002/maco.202213684 ↗
6. Shoujia L, Jianfei Y. Selection of cathodic protection for the bottom of oil tanks. China Storage Transp 2022; 04: 70–71.
7. Zhenjun L, Longhu A, Huaiyong Y, et al. The influence of anode ground beds on the regional cathodic protection of oil and gas station areas. Petroleum Eng Construct 2012; 38: 53–55.
8. 10.1016/j.engfailanal.2024.10798210.1016/j.engfailanal.2024.107982 ↗
9. 10.1016/0013-4686(64)80019-010.1016/0013-4686(64)80019-0 ↗
10. Xun X. Numerical simulation study of cathodic protection systems based on finite element method. Dalian University of Technology, 2014.
11. Fu JW, Chow JSK. Cathodic protection designs using an integral equation numerical method. Mater Perform 1982; 21: 9.
12. Yanping X, Yue L. Optimization of cathodic protection schemes for metal tanks based on Comsol multiphysics. J Petrochem Univ 2016; 29: 92–96.
13. 辛泽 Z. 油罐场区域阴极保护计划研究. 中国石油大学(华东), 2017年.
14. Dong W. Study on cathodic protection potential distribution of tank bottoms at Yaha loading south station. Southwest Petroleum University, 2015.
15. Yongji W. Research and application of models in cathodic protection design. Corros Sci Prot Technol 1999; 11: 99–104.
16. Xinguo Z, Xianji M, Xuwei L. Development and current status of cathodic protection system design methods. Port Eng 1996; 6: 50–54.
17. 10.1016/j.corsci.2004.07.01810.1016/j.corsci.2004.07.018 ↗
18. Xueming Y. Numerical calculation of cathodic protection for pipelines between wellheads and metering stations. Qingdao: China University of Petroleum (East China), 2017.
19. Guichang L, Wen S, Lida W. Segmental nonlinear boundary mathematical model for sacrificial anode cathodic protection in seawater. Corros Protect 2012; 33: 876–879. 907.
20. Xiangyi L, Yongji W. Analytical calculation method for cathodic protection potential distribution on the outer side of metal tank bottoms. Acta Petrolei Sinica 1998; 03: 110–115.
21. Shoubin S. Study on regional cathodic protection technology of La 291 based on numerical simulation. Northeast Petroleum University, 2012.
22. Shaowei C, Hartt WH. Characteristics of cathodic polarization of steel in seawater and new approaches to cathodic protection system design. Corros Sci Prot Technol 1996; 8: 17–25.
23. 10.1016/j.corsci.2004.07.01810.1016/j.corsci.2004.07.018 ↗
24. Wei W, Huyuan S, Lijuan S, et al. Finite element simulation of cathodic protection of 35 steel in seawater. Corros Protect 2009; 30: 462–465., 469.
25. Jianbin S. Regional cathodic protection technology for large steel tank groups. Beijing: Sinopec Press, 2009.
26. Yanxia D. Study on the potential distribution of cathodic protection on the outer side of metal tank bottoms. Qingdao: China University of Petroleum, 2007.
27. Yanxia D, Guozhong Z. Numerical simulation of cathodic protection potential distribution on the outer side of tank bottoms. J Chinese Soc Corros Protect 2006; 26: 346–350.
28. Dawei Z, Yanxia D, Taotao C, et al. Research and application of inversion calculation method for boundary conditions in regional cathodic protection numerical simulation. J Chinese Soc Corros Protect 2021; 41: 346–352.
29. 10.1016/S0955-7997(98)80012-X10.1016/S0955-7997(98)80012-X ↗
30. Longwei D, Kexi L, Bin D. Selection of soil resistivity in cathodic protection numerical calculation. Mater Protect 2015; 48: 16–19 + 7.
31. SY/T 0096-2013 Technical specification for impressed current deep anode ground bed [S].
32. Hongchen F, Xuelan C. Analysis and selection of cathodic protection methods for tank bottoms. Petroleum Eng Const 1997; 23: 37–39.
33. Du Y, Lu M, Dong L, et al. Study on the cathodic protection scheme in oil and gas transmission station based on numerical simulation. Corrosion 2011; 67: 1–14.
34. Design Fire Prevention Standards for Petrochemical Enterprises: GB 50160-2018. 2018.