Assessing the long term benefits of Impressed Current Cathodic Protection
Source abstract
Abstract
Abstract This experimental field study interrupted the protection current offered by Impressed Current Cathodic Protection (ICCP) to ten in-service reinforced concrete structures. The study aimed to identify the long-term effects of ICCP after it was recognised that some of the systems are now reaching the end of their design life and require a significant level of maintenance. It was found that after five or more years of ICCP, the steel remained passive for at least 24 months after interrupting the protection current despite chloride contamination that would represent a corrosion risk.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Conventional and pulse cathodic protection of reinforced concrete: electrochemical behaviour of the steel reinforcement after corrosion and protection10.1002/maco.200805150 ↗
2. BS EN 12696:2000, Cathodic Protection of Steel in Concrete, British Standards Institution, London, 2000.
3. Pourbaix · 1996
4. B.S Wyatt, Developments in Cathodic Protection of Steel in Concrete: Concrete Bridge Development Group, Annual Conference: Eurocodes and Innovation, Oxford, 2009.
5. An investigation into the mechanisms of protection afforded by a cathodic current and the implications for advances in the field of cathodic protection10.1016/0010-938X(94)90017-5 ↗
6. J.P. Broomfield, J.S. Tinnea, Cathodic Protection of Reinforced Concrete Bridge Components, Final Report. ID No: SHRPCUWP92618, 1992.
7. F.J. Presuel-Moreno, A.A. Sagüés, S.C. Kranc, Steel activation in concrete following interruption of long-term cathodic polarisation, Corrosion 2002 (Paper no. 02259).
8. Making reinforced concrete immune from chloride corrosion10.1680/coma.2007.160.4.155 ↗
9. The corrosion of steel in a reinforced concrete bridge10.5006/0010-9312-13.3.43 ↗
10. Half cell potential measurements–potential mapping on reinforced concrete structures, RILEM TC 154-EMC: electrochemical techniques for measuring metallic corrosion10.1007/BF02481526 ↗
11. BA 35/90, Inspection and Repair of Concrete Highway Structures, British Standards Institution, London, 1990.
12. Broomfiled · 1997
13. Electrochemical polarisation I: a theoretical analysis of the shape of polarisation curves10.1149/1.2428496 ↗
14. D.D. McDonald, M.C.H. McKubre, Electrochemical impedance techniques in corrosion science, in: F. Mansfeld, U. Bertocci (Eds.), Electrochemical Corrosion Testing ASTM STP 727, 1981, pp. 110–149.10.1520/STP28030S ↗
15. R. Polder, A. Tondi, R. Cigna, Concrete Resistivity and Corrosion Rate of Reinforcement, TNO Report 93-BT-r0170, TNO Delft, 1993.
16. Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarisation resistance method, RILEM TC 154-EMC: electrochemical techniques for measuring metallic corrosion10.1007/BF02483292 ↗
17. Concrete Society, Technical Report 60, Electrochemical Tests for Reinforcement Corrosion, Surrey, UK, 2004.
18. On-site measurements of corrosion rate of reinforcements10.1016/S0950-0618(00)00063-5 ↗
19. Obtaining impedance information on the steel–concrete interface10.5006/1.3284808 ↗
20. Hybrid corrosion protection of chloride-contaminated concrete10.1680/coma.2008.161.4.163 ↗
21. R. Polder, W.H.A. Peelen, B.T.J. Stoop, E.A.C. Neeft, Early Stage Beneficial Effects of Cathodic Protection in Concrete Structures, Nice, France, Eurocorr 2009.10.1201/9780203864005.ch53 ↗