journal article·2008-12

Metal release from stainless steel, Co–Cr–Mo–Ni–Fe and Ni–Ti alloys in vascular implants

Yoshimitsu Okazaki, Emiko Gotoh

Corrosion Science· Volume 50· Issue 12
Publisher page

Abstract

Abstract A seven-day immersion test using several solutions was conducted on stainless steel, Co-based alloy, and Ni–Ti alloy, which are used for stents and stent grafts. The quantitative data on the release of each metal ion and the correlation between metal ion release rate and pH were obtained. The quantities of Fe and Ni released from stainless steel gradually decreased with increasing solution pH (pH 2–7.5). For Co–Cr–Mo–Ni–Fe alloy, the quantity of Cr released steadily increased as pH decreased (pH ≤ 6) and reached nearly zero at pHs higher than 6 (pH 6–7.5). Co release was slightly affected by a variation in pH. The quantities of Ni and Ti released from Ni–Ti alloy markedly increased with decreasing pH (pH ≤ 4) and they leveled off from pH 4 (pH 4–7.5). Although the rapid increases were observed at approximately pH 2, the quantities were even higher than that of Co released from the Co–Cr–Mo and Co–Cr–Mo–Ni–Fe alloys. For further investigation of the rapid increase in the quantities of metals released at pH 2, an anodic polarization test was employed to study the passive and transpassive behaviours of Ni–Ti alloy. The critical current density for the passivation of Ni–Ti alloy markedly increased as pH decreased (pH ≤ 4) and was low (1.4 μA/cm2) at pH higher than 4 (pH 4–7.5). The potential at a current density of 10 μA/cm2, by contrast, markedly rose with decreasing pH (pH ≤ 2), and was 1.2 V from pH 2 (pH 2–7.5).
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (62)

Show source-provided references
1. Passivation of nitinol wire for vascular implants–a demonstration of the benefits10.1016/S0142-9612(01)00299-X ↗
2. Nitinol intravascular stent: results of preclinical evaluation10.1148/radiology.189.3.8234703 ↗
3. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents10.1002/(SICI)1097-4636(1999)48:2<165::AID-JBM11>3.0.CO;2-# ↗
4. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model10.1016/S0142-9612(02)00030-3 ↗
5. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide10.1002/1097-4636(200011)52:2<323::AID-JBM11>3.0.CO;2-Z ↗
6. Effects of Ti/TiN multilayer on corrosion resistance of nickel–titanium orthodontic brackets in artificial saliva10.1016/j.corsci.2007.03.041 ↗
7. Nickel ion release from orthodontic NiTi wires under simulation of realistic in-situ conditions10.1007/s10853-005-0448-7 ↗
8. Effects of cold drawing and annealing on mechanical properties and microstructure of Co–Cr–Mo–Ni–Fe Alloys for surgical implants10.2320/matertrans.MRA2007275 ↗
9. Metal release and excretion from cementless titanium alloy total knee replacements10.1097/00003086-199901000-00021 ↗
10. Metal ion levels in patients with stainless steel spinal instrumentation10.1097/BRS.0b013e318133aa0d ↗
11. Metal sensitivity in patients with orthopaedic implants10.2106/00004623-200103000-00017 ↗
12. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study10.2106/00004623-199810000-00006 ↗
13. Metal ion release after total hip replacement10.1016/0142-9612(80)90016-2 ↗
14. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties10.1002/(SICI)1097-4636(19991215)47:4<543::AID-JBM11>3.0.CO;2-G ↗
15. Urinary 8-hydroxydeoxyguanosine and sister chromatid exchanges in patients with total hip replacements10.1080/15287390252900359 ↗
16. The rationale for metal-on-metal total hip arthroplasty10.1097/01.blo.0000193809.85587.f8 ↗
17. Does ion release differ between hip resurfacing and metal-on-metal THA?10.1007/s11999-007-0106-2 ↗
18. Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings10.1002/jbm.10299 ↗
19. Chromium and cobalt ion release following the durom high carbon content, forged metal-on-metal surface replacement of the hip10.1302/0301-620X.89B4.18054 ↗
20. Elevated serum cobalt with metal-on-metal articulating surfaces10.1302/0301-620X.79B2.7326 ↗
21. Metal-on-metal total hip replacement – what does the literature say?10.1016/j.arth.2004.08.011 ↗
22. Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation10.1002/jbm.b.10070 ↗
23. Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results10.1002/jbm.a.10595 ↗
24. Serum protein carriers of chromium in patients with cobalt-base alloy total joint replacement components
25. Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement10.1302/0301-620X.88B4.17333 ↗
26. Current in vivo wear of metal-on-metal bearing assessed by exercise-related rise in plasma cobalt level10.1002/jor.20206 ↗
27. The clinical significance of metal ion release from cobalt–chromium metal-on-metal hip joint arthroplasty10.1243/09544119JEIM78 ↗
28. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
29. Surface modification of titanium alloy implants10.1016/0142-9612(94)90113-9 ↗
30. Corrosion resistance of implant alloys in Pseudo physiological solution and role of alloying elements in passive films10.2320/matertrans1989.38.78 ↗
31. Metal release from various grades of stainless steel exposed to synthetic body fluids10.1016/j.corsci.2006.05.008 ↗
32. Factors that influence the release of metals from stainless steels exposed to physiological media10.1016/j.corsci.2005.08.006 ↗
33. Corrosion-induced release of chromium and iron from ferritic stainless steel grade AISI 430 in stimulated food contact10.1016/j.jfoodeng.2007.12.006 ↗
34. Passive and transpassive behaviour of CoCrMo in simulated biological solutions10.1016/j.electacta.2003.12.043 ↗
35. Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants10.1002/jbm.a.30368 ↗
36. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
37. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys10.3233/BME-1996-6405 ↗
38. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
39. Effect of surface treatment and sterilization processes on the corrosion behaviour of NiTi shape memory alloy10.1002/1097-4636(20000915)51:4<685::AID-JBM17>3.0.CO;2-S ↗
40. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
41. Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release10.1002/jbm.a.30720 ↗
42. Patch test reactivity to a cobalt–chromium–molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release10.1111/j.1600-0536.2007.01139.x ↗
43. Implications of metallic corrosion in total knee arthroplasty10.1097/00003086-199110000-00004 ↗
44. ISO 5832-1, Implants for Surgery – Metallic materials – Part 1: Wrought Stainless Steel, 2007.
45. ISO 5832-9, Implants for Surgery – Metallic Materials – Part 9: Wrought High Nitrogen Stainless Steel, 2007.
46. Effects of solution treatment and cold rolling on microstructure and mechanical properties of stainless steel for surgical implants10.2320/matertrans.MRA2007299 ↗
47. Effects of heat treatment and hot forging on microstructure and mechanical properties of Co–Cr–Mo alloy for surgical implants10.2320/matertrans.MRA2007274 ↗
48. JIS T 0304, Testing Method for Metal Release from Metallic Biomaterials, 2002.
49. JIS T 0302, Testing Method for Corrosion Resistance of Metallic Biomaterials by Anodic Polarization Measurement, 2000.
50. ISO 16428, Implants for Surgery – Test Solutions and Environmental Conditions for Static and Dynamic Corrosion Tests on Implantable Materials and Medical Devices, 2005.
51. ISO 16429, Implants for Surgery – Measurements of Open-Circuit Potential to Assess Corrosion Behaviour of Metallic Implantable Materials and Medical Devices Over Extended Time Periods, 2004.
52. Official J European Union L 301, 27. 9. 2004, p. 51, Commission Directive 2004/96/EC, Amending Council Directive 76/769/EEC as Regards Restrictions on the Marketing and Use of Nickel for Piercing Post Assemblies for the Purpose of Adapting its Annex I to Technical Progress.
53. Characterization of Sandvik Bioline high-N-A comparison of standard grades F1314 and F1586 stainless steels for medical and surgical applications
54. Effect of chemical composition of man-made vitreous fibers on the rate of dissolution in vitro at different pHs10.1289/ehp.94102s583 ↗
55. Metal release from heat-treated orthodontic archwires10.3109/00016358709096365 ↗
56. ASTM F2063, Standard Specification for Wrought Nickel–Titanium Shape Memory Alloys for Medical Devices and Surgical Implants.
57. Cytotoxic, allergic and genotoxic activity of a nickel–titanium alloy10.1016/S0142-9612(97)00041-0 ↗
58. Comparative in vitro biocompatibility of nickel–titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation
59. Biocompatibility of nickel–titanium shape memory metal and its corrosion behavior in human cell cultures10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G ↗
60. Biocompatibility of nitinol alloy as an implant material10.1002/jbm.820100505 ↗
61. On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility10.1016/S0142-9612(01)00416-1 ↗
62. Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrations10.1002/(SICI)1097-4636(1999)48:4<488::AID-JBM14>3.0.CO;2-D ↗