journal article·2012-12

Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids

C. Vasilescu, S.I. Drob, E.I. Neacsu, J.C. Mirza Rosca

Corrosion Science· Volume 65
Publisher page

Abstract

A new quaternary Ti-20Nb-10Zr-5Ta alloy with 3-near microstructure was obtained. Its native passive film composition and its modification and corrosion resistance after 2000 immersion hours in simulated biofluids were studied. The native film on the alloy surface contains TiO2, Nb2O5, ZrO2, Ta2O5 protective oxides as was demonstrated by XPS. After 2000 h, XPS revealed the presence of same oxides and calcium, phosphorous ions deposited from physiological solutions as hydroxyapatite. In Ringer and Ringer-Brown solutions, the new alloy presented low corrosion rates. Impedance data exhibited a passive film with two layers: an inner, barrier layer and an outer, porous layer. (C) 2012 Elsevier Ltd. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. A new Ti–15Zr–4Nb–4Ta alloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
2. Characterization of air-formed surface oxide film on Ti–29Nb–13Ta–4.6Zr alloy surface using XPS and AES10.1016/j.corsci.2008.06.002 ↗
3. Comparative corrosion study of Ti–Ta alloys for dental application10.1016/j.actbio.2009.05.037 ↗
4. Influence of potential on the electrochemical behaviour of β titanium alloys in Hank’s solution10.1016/j.actbio.2007.02.009 ↗
5. Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V10.1016/S0142-9612(97)00235-4 ↗
6. Surface analysis of Ti–15Zr–4Nb–4Ta alloy after implantation in rat tibia10.1016/S0142-9612(00)00221-0 ↗
7. Corrosion resistance and corrosion fatigue strength of new titanium alloys for medical implants without V and Al10.1016/0921-5093(96)10247-1 ↗
8. Biocompatibility of β stabilizing elements of titanium alloys10.1016/j.biomaterials.2004.01.021 ↗
9. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
10. Investigation of the electrochemical behaviour and surface chemistry of a Ti–13Nb–13Zr alloy exposed in MEM cell culture media with and without the addition of H2O210.1002/sia.2616 ↗
11. Corrosion behavior of Ti–xNb–13Zr alloys in Ringer’s solution10.1002/maco.200805014 ↗
12. Corrosion and passivity of Ti–13%Nb–13%Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
13. Influence of fluoride concentration and pH on corrosion behaviour of Ti–6Al–4V and Ti–23Ta alloys in artificial saliva10.1002/maco.200604004 ↗
14. Electrochemical corrosion behavior of biomedical Ti–22Nb and Ti–22Nb–6Zr alloys in saline medium10.1002/maco.200805173 ↗
15. Evaluating electrochemical behaviour of recrystallized titanium alloys in Ringer’s solution10.1002/maco.201106185 ↗
16. Bioactive calcium phosphate invert glass-ceramic coating on β-type Ti–29Nb–13Ta–4.6Zr alloy10.1016/S0142-9612(02)00316-2 ↗
17. Formation and growth of calcium phosphate on the surface of oxidized Ti–29Nb–13Ta–4.6Zr10.1016/j.biomaterials.2003.09.039 ↗
18. Bone bonding bioactivity of Ti metal and Ti–Zr–Nb–Ta alloys with Ca ions incorporated on their surfaces by simple chemical and heat treatments10.1016/j.actbio.2010.09.026 ↗
19. Strengthening mechanisms in Ti–Nb–Zr–Ta and Ti–Mo–Zr–Fe orthopaedic alloys10.1016/j.biomaterials.2003.10.041 ↗
20. Characterization of Ti–35Nb–7Zr–5Ta alloy produced by powder metallurgy10.4028/www.scientific.net/MSF.498-499.34 ↗
21. Age-hardening of Ti–35Nb–7Zr–5Ta alloy for orthopaedic implants10.1590/S1516-14392007000300013 ↗
22. Corrosion susceptibility of implant materials Ti–5Al–4V and Ti–6Al–4Fe in artificial extra-cellular fluids10.1016/j.electacta.2003.12.036 ↗
23. Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids10.1016/j.corsci.2009.08.014 ↗
24. The relation between electrochemical tests and in vitro evaluation of titanium alloy biocompatibility
25. In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy10.1007/s10856-010-4057-x ↗
26. M. Popa, E. Vasilescu, P. Drob, D. Raducanu, J.M. Calderon Moreno, S. Ivanescu, C. Vasilescu, S.I. Drob, Microstructure, mechanical and anticorrosive properties of a new Ti–20Nb–10Zr–5Ta alloy based on non-toxic and non-allergic elements, Met. Mater.-Int., in press.
27. Hydration with Ringer’s lactate solution. Its effectiveness in maintaining stable circulation during and after surgery10.1001/jama.1966.03100070089025 ↗
28. Ringer’s lactate solution and extracellular fluid volume in the surgical patient: a critical analysis10.1097/00000658-196902000-00001 ↗
29. Moulder · 1995
30. Surface induced reactivity for titanium by ion implantation10.1023/A:1008938125348 ↗
31. Nucleation of corrosion pits in Ringer’s solution containing bovine serum10.1016/j.corsci.2007.05.018 ↗
32. A preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro10.1007/BF00154545 ↗
33. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
34. Black · 1992
35. Corrosion behaviour of porous titanium–graphite composite designed for surgical implants10.1016/S0010-938X(99)00103-1 ↗
36. Study of Ti6Al–4V biomaterial using electrochemistry and XPS techniques10.1590/S0100-40422002000100003 ↗
37. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
38. A hundred years of Tafel’s equation: 1905–200510.1016/j.corsci.2005.07.002 ↗
39. Validation of corrosion rates measured by the Tafel extrapolation method10.1016/j.corsci.2005.05.046 ↗
40. Electrochemical evaluation of Ti–13Nb–13Zr, Ti–6Al–4V and Ti–6Al–7Nb alloys for biomedical application by long-term immersion tests10.1002/maco.200604027 ↗
41. Corrosion behaviour of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in simulated fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
42. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti–6Al–7Nb alloy in Hank’s solution10.1023/B:JMSM.0000010097.86245.74 ↗
43. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
44. In vitro corrosion resistance of titanium using different fabrication methods10.1016/S0142-9612(98)00160-4 ↗
45. In vitro corrosion behaviour of Ti–5Al–2Nb–1Ta alloy in Hank’s solution10.1002/maco.200604001 ↗
46. Pourbaix · 1974
47. Electrochemical assessment on corrosion behavior of electrochemically joined dissimilar metal joins
48. Galvanic corrosion of titanium coupled to welded titanium in LiBr solutions at different temperatures10.1016/j.corsci.2009.02.023 ↗