journal article·2013-01

Corrosion resistance of Ti–6Al–4V alloy with nitride coatings in Ringer’s solution

I.M. Pohrelyuk, V.M. Fedirko, O.V. Tkachuk, R.V. Proskurnyak

Corrosion Science· Volume 66
Publisher page

Abstract

Abstract The corrosion behaviour of Ti–6Al–4V alloy with nitride coatings was investigated in Ringer’s solution at 36 and 40 °С. Nitride coatings of different composition, thickness and surface quality were formed because of changing nitrogen partial pressure from 1 to 10 5 Ра and nitriding temperature from 850 to 900 °С. Results shown that nitride coatings improve anticorrosion properties of alloy at both solution temperatures. Corrosion resistance of alloy increases with the content increase of TiN phase in nitride coating. With increase of temperature from 36 to 40 °С the corrosion resistance of alloy is determined significantly by quality of nitride coating.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties · Surface Treatment and Coatings

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Titanium is a highly thrombogenic biomaterial: possible implications for osteogenesis10.1055/s-0037-1614630 ↗
2. Titanium: the implant material of today10.1007/BF01133326 ↗
3. Influence of ion implantation on titanium surfaces for medical applications10.1016/j.susc.2007.04.060 ↗
4. Microstructure, microhardness and corrosion resistance of remelted TiG2 and Ti6Al4V by a high power diode laser10.1016/j.corsci.2011.11.006 ↗
5. Current products and practice. Nickel allergy and orthodontics10.1093/ortho/30.2.171 ↗
6. Lutjering · 2007
7. The synthesis of titanium alloys for biomedical applications
8. Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media10.1016/j.biomaterials.2005.08.012 ↗
9. Effect of different Ti–6Al–4V surface treatments on osteoblasts behaviour10.1016/S0142-9612(01)00266-6 ↗
10. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
11. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
12. Depth distributions and anodic polarization behaviour of ion implanted Ti6Al4V10.1016/S0010-938X(98)00062-6 ↗
13. Nitrogen ion implantation and in vitro corrosion behavior of as-cast Ti–6Al–7Nb alloy10.1016/S0010-938X(02)00034-3 ↗
14. Surface properties of plasma-nitrided titanium alloys10.1016/0921-5093(89)90404-8 ↗
15. Corrosion resistance properties of plasma nitrided Ti–6Al–4V alloy in hydrochloric acid solutions10.1016/S0010-938X(01)00157-3 ↗
16. Corrosion behaviour of glow discharge nitrided titanium alloys10.1016/S0010-938X(02)00139-7 ↗
17. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
18. Corrosion behaviour of laser gas nitrided Ti–6Al–4V in HCl solution10.1016/j.corsci.2009.06.016 ↗
19. Enhancing the microstructure and properties of titanium alloys through nitriding and other surface engineering methods10.1016/j.surfcoat.2004.07.115 ↗
20. Fedirko · 1995
21. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
22. Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti–6Al–4V in simulated physiological environment10.1016/j.jallcom.2004.03.096 ↗
23. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
24. Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys10.1016/j.corsci.2010.11.014 ↗
25. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25 and 37°C10.1016/j.corsci.2009.06.035 ↗
26. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
27. Corrosion behavior of TiN and TiN/Ti composite films on Ti6Al4V alloy in Hank’s solution10.1007/s10800-008-9690-4 ↗
28. Powder cell – a program for the representation and manipulation of crystal structures and calculation of the resulting X-ray powder patterns10.1107/S0021889895014920 ↗
29. Powder Diffraction File 1974: Search manual alphabetical listing and search section of frequently encountered phases, Inorganic, Philadelphia, 1974.
30. Computer processing of profilograms of friction surfaces10.1007/s11003-005-0138-2 ↗
31. Evaluation of hydroxyapatite coatings on borate passivated 316L SS in Ringer’s solution10.1016/j.msec.2008.08.020 ↗
32. Electrochemical and XPS studies of corrosion behavior of Ti–23Nb–0.7Ta–2Zr–O alloy in Ringer’s solution10.1016/j.matchemphys.2008.08.043 ↗
33. Goldschmidt · 1967
34. Improvement of mechanical properties of Ti/TiN multilayer films deposited by sputtering10.1016/S0257-8972(01)01021-0 ↗
35. High-flux low-energy (≈20eV) N+2 ion irradiation during TiN deposition by reactive magnetron sputtering: effects on microstructure and preferred orientation10.1063/1.359720 ↗
36. Zwicker · 1974
37. Positron annihilation studies of defects in PVD TiN coatings10.1016/0257-8972(94)02390-5 ↗