Composition and processing effects on the electrochemical characteristics of biomedical titanium alloys
Source abstract
Abstract
Abstract The electrochemical behaviour of the Ti–13Nb–13Zr and Ti–6Al–4V ELI alloys with martensitic microstructures was investigated by polarization and electrochemical impedance spectroscopy (EIS) in Ringer’s solution. The impedance spectra were interpreted by a two time-constants equivalent circuit. Both investigated alloys showed high corrosion resistance, but the thin and uniform passive film on the Ti–6Al–4V ELI alloy surface was more protective. The inner barrier and outer porous layer were highly resistant and capacitive. However, thicker and more porous passive film on the Ti–13Nb–13Zr alloy surface may be beneficial for osteointegration. The suitable thermomechanical processing improved the corrosion resistance of Ti–13Nb–13Zr alloy.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Additive Manufacturing Materials and Processes · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Titanium alloys in total joint replacement – a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
2. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
3. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
4. A comparison of the fatigue behavior of cast Ti–7.5Mo with c.p. titanium, Ti–6Al–4V and Ti–13Nb–13Zr alloys10.1016/j.biomaterials.2004.09.007 ↗
5. I. Cvijović-Alagić, Damage and Fracture Resistance of Titanium based Alloys for Medical Application, Ph.D. Thesis, University of Belgrade, 2013.
6. Determinants of stress shielding: design versus materials versus interface10.1097/00003086-199201000-00020 ↗
7. Corrosion behaviour of Ti–13Nb–13Zr alloy used as a biomaterial10.1016/j.jallcom.2008.09.026 ↗
8. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
9. Effect of thermomechanical processing on evolution of various phases in Ti–Nb–Zr alloys10.1016/j.jallcom.2004.04.113 ↗
10. Effect of thermomechanical processing on microstructure of a Ti–13Nb–13Zr alloy10.1016/S0925-8388(01)01604-8 ↗
11. The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
12. Microstructures and mechanical properties of a new titanium alloy for surgical implant application10.1007/s12613-010-0211-1 ↗
13. Effects of aluminium and other cations on the structure of brain and liver chromatin10.1021/bi00435a043 ↗
14. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells
15. Corrosion of surgical implants – in vivo and in vitro tests
16. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti–13Nb–13Zr alloy, and an austenitic stainless steel in Hank’s solution10.1002/jbm.b.30205 ↗
17. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids10.1016/j.corsci.2012.08.042 ↗
18. Surface and electrochemical characterization of a new ternary titanium based alloy behaviour in electrolytes of varying pH10.1016/j.corsci.2013.07.026 ↗
19. Surface characterization of oxides grown on the Ti–13Nb–13Zr alloy and their corrosion protection10.1016/j.corsci.2013.02.007 ↗
20. Fatigue behavior of arc melted Ti–13Nb–13Zr alloy10.1016/j.ijfatigue.2004.01.011 ↗
21. Corrosion behavior of Ti–xNb–13Zr alloys in Ringer’s solution10.1002/maco.200805014 ↗
22. Electrochemical behavior of Ti-based alloys in simulated human body fluid environment
23. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
24. Influence of microstructure and alloying elements on corrosion behavior of Ti–13Nb–13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
25. Conjoint corrosion and wear in titanium alloys10.1016/S0142-9612(98)00229-4 ↗
26. Corrosion resistance of anodic oxides on the Ti–50Zr and Ti–13Nb–13Zr alloys10.1016/j.electacta.2005.07.015 ↗
27. Corrosion behavior of Ti–6Al–4V with different thermomechanical treatments and microstructures10.5006/1.3452400 ↗
28. Corrosion and passivity of Ti–13%Nb–13%Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
29. Electrochemical evaluation of Ti–13Nb–13Zr, Ti–6Al–4V and Ti–6Al–7Nb alloys for biomedical application by long-term immersion tests10.1002/maco.200604027 ↗
30. The electrochemical behaviour of Ti–13Nb–13Zr alloy in various solutions10.1002/maco.200804148 ↗
31. Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids10.1016/j.corsci.2009.08.014 ↗
32. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
33. Mechanical and corrosion behaviour of a Ti–Al–Nb alloy after deformation at elevated temperatures10.1002/maco.200805003 ↗
34. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
35. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti–6Al–7Nb alloy in Hank’s solution10.1023/B:JMSM.0000010097.86245.74 ↗
36. Variation of oxide films on titanium induced by osteoblast-like cell culture and the influence of an H2O2 pretreatment10.1002/(SICI)1097-4636(199805)40:2<244::AID-JBM9>3.0.CO;2-L ↗
37. Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys in simulated physiological solution10.1016/j.corsci.2010.11.014 ↗
38. Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopy10.1016/S0142-9612(03)00362-4 ↗
39. Influence of hydroxyapatite on the corrosion resistance of the Ti–13Nb–13Zr alloy10.1007/s10856-008-3662-4 ↗
40. Photo-electrochemical and impedance investigation of passive layers grown anodically on titanium alloys10.1016/j.electacta.2004.04.042 ↗
41. Effect of surface treatment on electrochemical behavior of CP Ti, Ti–6Al–4V and Ti–13Nb–13Zr alloys in simulated humanbody fluid10.1016/j.corsci.2005.06.003 ↗
42. Voltammetric stability of anodic films on the Ti6Al4V alloy in chloride medium10.1016/j.electacta.2006.04.051 ↗
43. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
44. Electrochemical investigations of Ti6Al4V and Ti6Al7Nb alloys used on implants in bone surgery
45. Effects of scan rate on the potentiodynamic polarization curve obtained to determine the Tafel slopes and corrosion current density10.1016/j.corsci.2008.12.005 ↗
46. Characterisation and corrosion resistance of the electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti–6Al–4V–1Zr alloy surface10.1016/j.corsci.2010.11.033 ↗
47. Corrosion resistance of Ti–6Al–4V alloy with nitride coatings in Ringer’s solution10.1016/j.corsci.2012.10.005 ↗
48. New surface-hardened, lowmodulus, corrosion-resistant Ti–13Nb–13Zr alloy for total hip arthroplasty
49. Phase transformations during cooling in α+β titanium alloys10.1016/S0921-5093(97)00802-2 ↗
50. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
51. Electrochemical polarization. I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
52. Study of Ti–6Al–4V biomaterial using electrochemistry and XPS techniques10.1590/S0100-40422002000100003 ↗
53. On the stability of thin-anodic-oxide films of titanium in acid phosphoric media10.1016/S0010-938X(00)00162-1 ↗
54. Preparation and surface spectroscopic characterization of oxide films on Ti6Al4V10.1016/0169-4332(89)90013-5 ↗
55. Corrosion resistance of implant alloys in pseudo physiological solution and role of alloying elements in passive films10.2320/matertrans1989.38.78 ↗
56. Possible reasons for the unexpected bad biocompatibility of metal-on-metal hip implants10.1016/j.msec.2005.05.004 ↗
57. Corrosion behaviour of niobium in phosphate buffered saline solutions with different concentrations of bovine serum albumin10.1016/j.corsci.2011.12.039 ↗