Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids
Source abstract
Abstract
Ti6Al4V-ELI alloy was plastically deformed at elevated temperatures in the range of beta and alpha + beta fields and was subsequently heat treated; so that five different alloys were obtained. The corrosion resistance of these alloys was studied in Ringer solutions of different pH values using the techniques of electrochemical cyclic potentiodynamic polarization, electrochemical impedance spectroscopy and scanning electron microscopy. All alloys exhibited high corrosion resistance in Ringer solutions for 2000 exposure hours. SEM observations indicated the formation of calcium phosphate on the alloy surface. Two electric equivalent circuits with two time or three time constants were fitted. (C) 2009 Elsevier Ltd. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. Characterization of implant material in fetal bovine serum and sodium sulfate by the electrochemical impedance spectroscopy. I. Mechanically polished samples10.1002/jbm.10329 ↗
2. Corrosion of Ti-6Al-4V in simulated body fluids and bovine plasma10.1002/jbm.820060304 ↗
3. Surface treatments and roughness properties on Ti-based biomaterials10.1023/B:JMSM.0000042679.28493.7f ↗
4. Effect of surface treatment on electrochemical behavior of CP Ti, Ti-6Al-4V and Ti-13Nb-13Zr alloys in simulated human body fluid10.1016/j.corsci.2005.06.003 ↗
5. In vitro corrosion and wear of titanium alloys in the biological environments10.1016/0142-9612(96)00029-4 ↗
6. Influence of sintering on the corrosion behaviour of a Ti-6Al-4V alloy10.1002/maco.200403818 ↗
7. Accumulation of aluminium in lamellar bone after implantation of titanium plates, Ti-6Al-4V screws, hydroxyapatite granules10.1016/j.biomaterials.2003.10.020 ↗
8. In vitro and in vivo performance of Ti6Al4V implants with plasma-sprayed osteoinductive hydroxylapatite-bioinert titania bond coat “duplex” systems: an experimental study in sheep10.1023/B:JMSM.0000042691.74922.1b ↗
9. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photo electron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
10. Attachment and proliferation of neonatal rat calvarial osteoblasts on Ti6Al4V: effect of surface chemistries of the alloy10.1016/S0142-9612(03)00465-4 ↗
11. Transforming growth factor β1 immobilized adsorbtively on Ti6Al4V and collagen type I coated Ti6Al4V maintains its biological activity10.1016/S0142-9612(03)00068-1 ↗
12. The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour10.1016/S0142-9612(00)00042-9 ↗
13. Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopy10.1016/S0142-9612(03)00362-4 ↗
14. Corrosion resistance properties of plasma nitrided Ti-6Al-4V alloy in nitric acid solutions10.1016/S0010-938X(03)00188-4 ↗
15. Electrochemical characterisation of oxide films formed on Ti-6Al-4V alloy implanted with Ir for bioengineering applications10.1016/S0013-4686(97)00226-0 ↗
16. Electrochemical behaviour of Ti-Mo alloys applied as biomaterial10.1016/j.corsci.2007.09.009 ↗
17. Point defect model and corrosion of anodic oxide coatings on Ti-6Al-4V10.1016/j.corsci.2008.02.023 ↗
18. X-ray photoelectron spectroscopic comparison of sputtered Ti, Ti6Al4V and passivated bulk metals for use in cell culture techniques10.1116/1.577621 ↗
19. Preparation and surface spectroscopic characterization of oxide films on Ti6Al4V10.1016/0169-4332(89)90013-5 ↗
20. Corrosion resistance, mechanical properties fatigue strength and cytocompatibility of new Ti alloys without Al and V10.1016/S0142-9612(97)00235-4 ↗
21. Surface characterisation of titanium alloys sterilized for biomedical applications10.1016/0169-4332(93)90220-6 ↗
22. Corrosion behaviour and microstructure of titanium implanted with α and β stabilizing elements10.1016/S0040-6090(97)00330-1 ↗
23. Corrosion resistance of implant alloys in pseudo physiological solution and role of alloying elements in passive films10.2320/matertrans1989.38.78 ↗
24. EIS study of Ti and its alloys in biological media10.1016/S0022-0728(02)00814-8 ↗
25. Correlation of tissue reaction to corrosion in osteosynthethic devices10.1002/jbm.820180712 ↗
26. The interface zone of inorganic implants in vivo: titanium implants in bone10.1007/BF02363944 ↗
27. Retrieval study of stainless steel and titanium miniplates and strews used in maxillofacial surgery10.1007/BF00122394 ↗
28. In situ characterization of passive films on Al-Ti alloy by photocurrent and impedance spectroscopy10.1016/S0010-938X(98)00009-2 ↗
29. Corrosion fatigue resistances of surgical implant stainless steel and titanium alloys10.1016/0010-938X(93)90193-K ↗
30. Titanium alloys, ASM Int.1994, ISBN 0-87170-481-1, 50.
31. The α/β interface phase in titanium alloys: artifact or real phase contribution to problem resolution10.1007/BF02647969 ↗
32. Corrosion resistance of some thermo-mechanical treated titanium bioalloy depending on pH of Ringer solution
33. ISO 8044/2000.
34. Comparative EIS study on a paste electrode containing zinc powder in neutral and near neutral solutions10.1007/s100080000192 ↗
35. Nucleation of corrosion pits in Ringer’s solution containing bovine serum10.1016/j.corsci.2007.05.018 ↗
36. Electrochemical behaviour of some titanium alloy in comparison with base metal
37. The relation between electrochemical tests and in vitro evaluation of titanium alloy biocompatibility10.1002/maco.200704053 ↗
38. Study of Ti-6Al-4V biomaterial using electrochemistry and XPS techniques10.1590/S0100-40422002000100003 ↗
39. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
40. ISO TR 10271/1993.
41. Origins of pitting corrosion10.1179/147842204225016859 ↗
42. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
43. Pourbaix · 1974
44. Corrosion susceptibility of implant materials Ti-5Al-4V and Ti-6Al-4Fe in artificial extra-cellular fluids10.1016/j.electacta.2003.12.036 ↗
45. Long-term assessment of the implant titanium material – artificial saliva interface10.1007/s10856-007-3271-7 ↗
46. Monitoring of titanium base alloys – biofluids interface10.1016/j.bioelechem.2007.02.007 ↗
47. In vitro corrosion resistance of titanium made using different fabrication methods10.1016/S0142-9612(98)00160-4 ↗
48. The implant material of today10.1007/BF01133326 ↗
49. Corrosion and passivity of Ti-13%Nb-13%Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
50. In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when gallvanically coupled with carbon10.1002/jbm.820130106 ↗
51. Q. Guo, M. Du, C. Zhou, Study of galvanic corrosion of carbon steel/titanium and carbon steel/titanium/navel brass in seawater, 16th International Corrosion Congress, Beijing, China, 19–24 Sept., 2005, pp. 1–8.
52. Electrochemical evaluation of Ti-13Nb-13Zr, Ti-6Al-4V and Ti-6Al-7Nb alloys for biomedical application by long-term immersion tests10.1002/maco.200604027 ↗
53. Electrochemical impedance spectroscopic studies of titanium and its alloys in saline medium10.1002/maco.200603979 ↗