Effect of titania anodic formation and hydroxyapatite electrodeposition on electrochemical behaviour of Ti–6Al–4V alloy under fretting conditions for biomedical applications
Source abstract
Abstract
The comparative tribo-electrochemical behaviour of both untreated Ti–6Al–4V alloy surface and the modified surface by forming nanoporous titania layer followed by electrodeposition of hydroxyapatite coatings into nanoporous titania layer have been investigated in physiological fluid solution. The in situ electrochemical techniques used for investigation of tribo-electrochemical degradation were the open circuit potential (OCP) and the electrochemical impedance spectroscopy (EIS) measurements performed before, during and after fretting tests. The results show that both surface modification techniques applied can significantly enhance the tribo-electrochemical performances of Ti–6Al–4V alloy surface for biomedical applications.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
2. On the stability of thin-anodic-oxide films of titanium in acid phosphoric media10.1016/S0010-938X(00)00162-1 ↗
3. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
4. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrided Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
5. Surface modification of CP–Ti to improve the fretting-corrosion resistance. Thermal oxidation vs. anodizing10.1016/j.msec.2010.03.024 ↗
6. Phosphoric acid anodization of Ti–6Al–4V – structural and corrosion aspects10.1016/j.corsci.2006.06.021 ↗
7. Preparation of TiO2 layers on cp-Ti and Ti6Al4V by thermal and anodic oxidation and by sol–gel coating techniques and their characterization10.1002/jbm.1212 ↗
8. Preparation of titanium oxide and hydroxyapatite on Ti–6Al–4V alloy surface and electrochemical behavior in bio-simulated fluid solution10.1016/j.corsci.2013.11.059 ↗
9. Characterisation and corrosion resistance of the electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti–6Al–4V–1Zr alloy surface10.1016/j.corsci.2010.11.033 ↗
10. Electrochemical deposition of bioactive coatings on Ti and Ti–6Al–4V surfaces10.1016/j.surfcoat.2011.04.040 ↗
11. Hydroxyapatite coating on titanium substrate by electrophoretic deposition method: Effects of titanium dioxide inner layer on adhesion strength and hydroxyapatite decomposition10.1016/j.surfcoat.2007.09.031 ↗
12. Effect of gun current on the microstructure and crystallinity of plasma sprayed hydroxyapatite coatings10.1016/j.apsusc.2007.02.183 ↗
13. Preparation and characterization of hydroxyapatite coatings on Ti6Al4V alloy by a sol–gel method10.1111/j.1151-2916.1999.tb01719.x ↗
14. Effects of biomimetically and electrochemically deposited nanohydroxyapatite coatings on osseointegration of porous titanium implants10.1016/j.tripleo.2008.12.023 ↗
15. Hydroxyapatite coating on titanium surface with titania nanotube layer and its bond strength to substrate10.1007/s10934-009-9307-2 ↗
16. Electrodeposition of hydroxyapatite onto nanotubular TiO2 for implant applications10.1016/j.surfcoat.2006.09.008 ↗
17. Influence of anodization on the adhesion of calcium phosphate coatings on titanium substrates10.1002/jbm.a.32652 ↗
18. Significance of tribocorrosion in biomedical applications: overview and current status10.1155/2009/250986 ↗
19. Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys in simulated physiological solution10.1016/j.corsci.2010.11.014 ↗
20. The corrosion/wear mechanisms of Ti–6Al–4V alloy for different scratching rates10.1016/j.wear.2006.11.025 ↗
21. The corrosion-wear behaviour of thermally oxidised Cp–Ti and Ti–6Al–4V10.1016/S0043-1648(03)00557-X ↗
22. Fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva containing varying concentrations of fluoride ions10.1016/j.wear.2010.09.008 ↗
23. Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems10.1016/j.triboint.2013.09.022 ↗
24. TEM-EDX study of mechanism of bonelike apatite formation on bioactive titanium metal in simulated body fluid10.1002/1097-4636(20011205)57:3<441::AID-JBM1187>3.0.CO;2-B ↗
25. Novel bioactive materials with different mechanical properties10.1016/S0142-9612(03)00044-9 ↗
26. Deposition of calcium phosphate coating on nanotubular anodized titanium10.1016/j.matlet.2005.01.084 ↗
27. Do oral biofilms influence the wear and corrosion behavior of titanium?10.1080/08927011003767985 ↗
28. Biocompatibility of titanium implants modified by microarc oxidation and hydroxyapatite coating10.1002/jbm.a.30244 ↗
29. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
30. A histomorphometric evaluation of screw – shaped implants each prepared with two surface roughnesses10.1034/j.1600-0501.1998.090102.x ↗
31. Evaluation of hydrogen absorption behaviour during acid etching for surface modification of commercial pure Ti, Ti–6Al–4V and Ni–Ti superelastic alloys10.1016/j.corsci.2009.12.029 ↗
32. Surface characteristics and bioactivity of oxide films formed by anodic spark oxidation on titanium in different electrolytes10.1016/j.jmatprotec.2008.02.055 ↗
33. Fretting corrosion behaviour of thermally oxidized CP-Ti in Ringer’s solution10.1016/j.corsci.2009.10.029 ↗
34. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
35. Improvement of corrosion-wear resistance of Ti-6Al-4V alloy by plasma Mo-N surface modification10.1002/adem.200400207 ↗
36. Effect of sliding wear on tribocorrosion behaviour of stainless steels in a Ringer’s solution10.1016/j.wear.2006.03.003 ↗
37. The influence of chloride and sulphate ions on the corrosion behavior of Ti and Ti–6Al–4V alloy in oxalic acid10.1016/j.electacta.2008.12.060 ↗
38. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
39. Green approach to corrosion inhibition of 304 stainless steel in hydrochloric acid solution by the extract of Salvia officinalis leaves10.1016/j.corsci.2012.05.003 ↗
40. The global and local impedance response of a blocking disk electrode with local constant-phase-element behavior10.1149/1.2398889 ↗
41. Preparation and characterization of biomimetically and electrochemically deposited hydroxyapatite coatings on micro-arc oxidized Ti–13Nb–13Zr10.1007/s10856-011-4338-z ↗
42. Hydroxyapatite thin film coatings on nanotube-formed Ti–35Nb–10Zr alloys after femtosecond laser texturing10.1016/j.surfcoat.2012.11.066 ↗