Influence of transverse cracks and interfacial damage on corrosion of steel in concrete with and without fiber hybridization
Source abstract
Abstract
Abstract This study aims to correlate the role of transverse cracks and their associated interfacial steel-concrete damage to corrosion activity of steel reinforcing bars embedded in plain and hybrid fiber-reinforced concrete. Both the transverse cracks and the interfacial damage were artificially induced in a controlled manner. Corrosion rates and corrosion damage were found to increase with the presence of the transverse crack and were further aggravated by the interfacial disturbance. The inclusion of hybrid fibers in concrete reduced the corrosion activity and mass loss of the steel reinforcing bars, and limited the propagation and opening of the corrosion-induced splitting cracks.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Bertonini · 2004
2. Characterization of atomic structure of oxide films on carbon steel in simulated concrete pore solutions using EELS10.1016/j.apsusc.2013.03.014 ↗
3. The effect of simulated concrete pore solution composition and chlorides on the electronic properties of passive films on carbon steel rebar10.1016/j.corsci.2016.01.027 ↗
4. Corrosion of reinforcing steel in concrete: effects of materials, mix composition, and cracking
5. Influences of bending crack and water-cement ratio on chloride-induced corrosion of main reinforcing bars and stirrups
6. The influence of cracks on chloride-induced corrosion of steel in ordinary Portland cement and high performance concretes subjected to different loading conditions10.1016/j.corsci.2008.09.018 ↗
7. The influence of longitudinal cracks on the corrosion protection afforded reinforcing steel in high performance concrete10.1016/j.cemconres.2008.03.018 ↗
8. Influence of crack frequency on reinforcement corrosion in concrete10.1016/S0008-8846(96)85022-8 ↗
9. Laboratory studies and calculations on the influence of crack width on chloride-induced corrosion of steel in concrete
10. Effect of crack width and bar types on corrosion of steel in concrete10.1061/(ASCE)0899-1561(2001)13:3(194) ↗
11. Hartt · 2009
12. Corrosion in cracked and uncracked concrete–influence of crack width, concrete quality and crack reopening10.1680/macr.2010.62.6.393 ↗
13. Chloride corrosion of reinforcing steel in cracked concrete
14. Corrosion initiation in cracked fiber reinforced concrete: influence of crack width, fiber type and loading conditions10.1016/j.corsci.2015.05.021 ↗
15. Corrosion characteristics of a 4-year naturally corroded reinforced concrete beam with load-induced transverse cracks10.1016/j.corsci.2017.01.002 ↗
16. Effect of microcracking and cracking on the development of corrosion in reinforced concrete members10.1680/macr.1999.51.2.143 ↗
17. Corrosion initiation of reinforcing steel in concrete under natural salt spray and service loading—results and analysis
18. Influence of steel – concrete interface quality on reinforcement corrosion induced by chlorides10.1680/macr.2003.55.2.151 ↗
19. Experimental investigation of the relation between damage at the concrete-steel interface and initiation of reinforcement corrosion in plain and fiber reinforced concrete10.1016/j.corsci.2013.08.019 ↗
20. The steel–concrete interface10.1617/s11527-017-1010-1 ↗
21. Self-consolidating hybrid fiber reinforced concrete: development, properties and composite behavior10.1016/j.conbuildmat.2015.12.062 ↗
22. Corrosion of steel bars in concrete with various steel surface conditions
23. Half-cell potential mapping to assess repair work on RC structures10.1016/S0950-0618(00)00062-3 ↗
24. American Society for Testing and Materials (ASTM) · 2015
25. Macrocell and microcell corrosion of steel in ordinary Portland cement and high performance concretes10.1016/j.cemconres.2006.07.005 ↗
26. American Society for Testing and Materials (ASTM) · 2007
27. Macrocell corrosion of steel in concrete – implications for corrosion monitoring10.1016/S0958-9465(01)00027-0 ↗
28. Gamry Instruments Inc · 2011
29. The iR drop–well‐known but often underestimated in electrochemical polarization measurements and corrosion testing10.1002/maco.200603982 ↗
30. Electrochemical polarization I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
31. On the applicability of the Stern–Geary relationship to determine instantaneous corrosion rates in macro‐cell corrosion10.1002/maco.201407997 ↗
32. Steady-state polarization response of chloride-induced macrocell corrosion systems in steel reinforced concrete—numerical and experimental investigations10.1016/j.cemconres.2015.09.021 ↗
33. Errors in the electrochemical evaluation of very small corrosion rates—I. Polarization resistance method applied to corrosion of steel in concrete10.1016/0010-938X(85)90021-6 ↗
34. American Society for Testing and Materials (ASTM) · 2017
35. Quantifying chloride-induced corrosion from half-cell potential10.1016/0008-8846(93)90081-J ↗
36. American Society for Testing and Materials (ASTM) · 2009
37. Corrosion rate monitoring in the laboratory and on-site10.1016/0950-0618(95)00044-5 ↗
38. Hall-cell potential measurements—potential mapping on reinforced concrete structures10.1007/BF02481526 ↗
39. Electrochemical behaviour of steel rebars in concrete: influence of environmental factors and cement chemistry10.1016/S0013-4686(01)00678-8 ↗
40. Quantitative interpretation of half-cell potential measurements in concrete structures10.1061/(ASCE)0899-1561(2009)21:9(467) ↗
41. Influence of environmental parameters on application of standard ASTM C876-91: half cell potential measurements10.1179/174327807X214572 ↗
42. Effect of steel microfibers on corrosion of steel reinforcing bars10.1016/j.cemconres.2007.04.012 ↗
43. “Green rust”, iron solubility and the role of chloride in the corrosion of steel at high pH10.1016/0008-8846(93)90032-5 ↗
44. Mechanism of corrosion protection in reinforced concrete marine structures10.1038/258514a0 ↗
45. On the mechanism of localized corrosion of iron and stainless steel I. Electrochemical studies10.1149/1.2403982 ↗
46. Tension stiffening in reinforced high performance fiber reinforced cement-based composites10.1016/j.cemconcomp.2014.03.004 ↗
47. Mechanical properties of hybrid fiber-reinforced concrete at low fiber volume fraction10.1016/S0008-8846(02)00913-4 ↗
48. Mechanical properties of high-strength steel fiber-reinforced concrete10.1016/j.conbuildmat.2004.04.027 ↗
49. Strength properties of nylon- and polypropylene-fiber-reinforced concretes10.1016/j.cemconres.2004.06.033 ↗
50. Influence of service cracking on reinforcement steel corrosion10.1061/(ASCE)0899-1561(1998)10:1(14) ↗
51. Effect of damage in reinforced concrete on carbonation or chloride penetration10.1016/0008-8846(88)90033-6 ↗
52. Chloride ingress in cement paste and mortar10.1016/S0008-8846(99)00131-3 ↗
53. Capillary suction and diffusion model for chloride ingress into concrete10.1016/j.cemconres.2008.06.006 ↗
54. Critical chloride content in reinforced concrete—a review10.1016/j.cemconres.2009.08.006 ↗
55. Experimental observations of self-consolidated hybrid fiber reinforced concrete (SC-HyFRC) on corrosion damage reduction10.1016/j.conbuildmat.2015.12.076 ↗
56. Enhancing corrosion resistance of reinforced concrete structures with hybrid fiber reinforced concrete10.1016/j.corsci.2014.12.003 ↗
57. Influence of matrix cracking and hybrid fiber reinforcement on the corrosion initiation and propagation behaviors of reinforced concrete10.1016/j.corsci.2018.06.004 ↗
58. Analysis of progressive damage to reinforced ordinary and high performance concrete in relation to loading10.1007/BF02486411 ↗
59. Corrosion of reinforcement in relation to presence of defects at the interface between steel and concrete10.1061/(ASCE)0899-1561(2005)17:4(447) ↗
60. Influence of steel-concrete interface condition on galvanic corrosion currents in carbonated concrete10.1016/j.corsci.2010.04.037 ↗
61. Influence of steel–concrete interface defects induced by top-casting on development of chloride-induced corrosion in RC beams under sustained loading10.1617/s11527-016-0852-2 ↗
62. Pore solution composition and chloride effects on the corrosion of steel in concrete10.5006/1.3583967 ↗