Is it possible to use the Langmuir Isotherm in electrochemical studies? A critical view on the subject
Source abstract
Abstract
This article undertakes a critical evaluation of the literature regarding the use of the Langmuir isotherm, specifically in the context of inhibitor research. The Langmuir isotherm is frequently employed to derive thermodynamic and kinetic parameters, which are then used to gauge inhibitor performance. However, the validity of the Langmuir isotherm has been challenged, particularly by Walczak et al. (2019), whose work has served as a basis for others to reject its use as inadequate. Imposing limitations on the Langmuir isotherm would involve restrictions on heterogeneous kinetics, impedance interpretation, and other transient techniques. These aspects will be subjected to a more in-depth analysis in this discussion paper.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical Analysis and Applications · Corrosion Behavior and Inhibition · Molecular Junctions and Nanostructures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. Study of furfural derivatives as a possible green corrosion inhibitor for mild steel in CO2-saturated formation water10.1016/j.corsci.2022.110907 ↗
2. On the estimation of standard adsorption free energy from corrosion inhibition efficiencies10.1016/j.corsci.2023.111139 ↗
3. A general-purpose adsorption isotherm for improved estimation of standard adsorption free energy10.1016/j.corsci.2023.111124 ↗
4. Corrosion inhibitors: physisorbed or chemisorbed?10.1016/j.corsci.2021.109939 ↗
5. Determining Gibbs energies of adsorption from corrosion inhibition efficiencies: is it a reliable approach?10.1016/j.corsci.2019.04.040 ↗
6. Integrating experiments, DFT and characterization for comprehensive corrosion inhibition studies - a case for cinnamaldehyde as an excellent green inhibitor for steels in acidic media10.1016/j.corsci.2022.110623 ↗
7. Corrosion inhibitor distribution on abrasive-blasted steels10.1016/j.jcis.2022.12.003 ↗
8. Standard practice for preparing, cleaning, and evaluation corrosion test specimens
9. Discussion and challenges concerning the elaboration of a dissolution reaction mechanism10.1016/j.electacta.2019.02.036 ↗
10. Corrosion rate of iron and iron–chromium alloys in CO2 medium10.1016/j.corsci.2005.05.052 ↗
11. Electrochemical methods in corrosion on petroleum industry: laboratory and field results10.1016/S0013-4686(01)00675-2 ↗
12. Mechanism of anodic dissolution of iron-chromium alloys investigated by electrode impedances—II. Elaboration of the reaction model10.1016/0013-4686(86)80128-1 ↗
13. Determining the chemical composition of corrosion inhibitor/metal interfaces with XPS: minimizing post immersion oxidation
14. Rhamnolipid as an eco-friendly corrosion inhibitor for microbiologically influenced corrosion10.1016/j.corsci.2022.110390 ↗
15. Developing a robust thiadiazole derivative corrosion inhibitor for dynamic supercritical CO2 aqueous environment: electrochemical tests and DFT calculations10.1016/j.corsci.2022.110695 ↗
16. Corrosion inhibitor binding in an acidic medium: Interaction of 2-mercaptobenizmidazole with carbon-steel in hydrochloric acid10.1016/j.corsci.2014.04.003 ↗
17. Corrosion inhibition of carbon-steel with 2-mercaptobenzimidazole in hydrochloric acid10.1016/j.corsci.2015.08.032 ↗
18. Corrosion inhibition of carbon steel in hydrochloric acid: elucidating the performance of an imidazoline-based surfactant10.1016/j.corsci.2020.109195 ↗
19. Discussion on “Electrochemistry of CO2 corrosion of mild steel: effect of CO2 on iron dissolution reaction” by A. Kahyarian, B. Brown, S. Nesic, [Corros. Sci. 129 (2017) 146]10.1016/j.corsci.2018.02.004 ↗
20. Rotating disc and hemispherical electrodes for copper dissolution study in hydrochloric solution in the presence of benzotriazole10.1016/S0013-4686(00)00719-2 ↗