journal article·2023-07

Corrosion behavior of anodized Ti-Ta binary surface alloys in various physiological fluids for implant applications

Anusha Thampi V V, S. Ramanathan

Corrosion Science· Volume 219
Publisher page

Abstract

In this study, corrosion-resistant surface-modified biometals were developed by coating titanium-tantalum alloy thin films onto titanium substrates, followed by anodization. These films were systematically investigated for their crystal structure, morphology, and microstructure. Electrochemical studies were carried out in 0.9% NaCl, PBS, and SBF. EIS data was evaluated using equivalent circuit models and a physical model is proposed to describe the corrosion process. The polarization resistance values suggest that the anodized Ti-Ta thin film alloy possesses favorable corrosion resistance properties, thereby indicating its potential for use in orthopedic applications.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (73)

Show source-provided references
1. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
2. Surface engineering of nanostructured Ta surface with incorporation of osteoconductive elements by anodization10.1016/j.apsusc.2019.143573 ↗
3. Characterization of different materials for corrosion resistance under simulated body fluid conditions10.1016/S1044-5803(02)00320-0 ↗
4. Review of recent developments in surface nanocrystallization of metallic biomaterials10.1039/D0NR07566C ↗
5. Mechanical and biological properties of graded porous tantalum coatings deposited on titanium alloy implants by vacuum plasma spraying10.1016/j.surfcoat.2019.05.003 ↗
6. Osteogenic potential of additively manufactured TiTa alloys10.1021/acsabm.0c01450 ↗
7. Ti based biomaterials the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
8. Evaluation of the mechanical compatibility of additively manufactured porous Ti-25Ta alloy for load-bearing implant applications10.1016/j.jmbbm.2019.05.019 ↗
9. 3D printing of a titanium-tantalum Gyroid scaffold with superb elastic admissible strain bioactivity and in-situ bone regeneration capability
10. Low elastic modulus Ti-Ta alloys for load-bearing permanent implants: enhancing the biodegradation resistance by electrochemical surface engineering10.1016/j.msec.2014.10.038 ↗
11. Microstructural, mechanical and biological characterizations of the promising titanium-tantalum alloy for biomedical applications10.1016/j.jallcom.2017.11.392 ↗
12. Synthesis of Ti-Ta alloys with dual structure by incomplete diffusion between elemental powders10.1016/j.jmbbm.2015.07.004 ↗
13. Improvement on mechanical properties and corrosion resistance of titanium-tantalum alloys in-situ fabricated via selective laser melting10.1016/j.jallcom.2019.06.307 ↗
14. Laser powder bed fusion of titanium-tantalum alloys: compositions and designs for biomedical applications10.1016/j.jmbbm.2020.103775 ↗
15. Crystallographic structure analysis of a Ti-Ta thin film materials library fabricated by combinatorial magnetron sputtering10.1021/acscombsci.7b00135 ↗
16. High-temperature shape memory effect in Ti-Ta thin films sputter deposited at room temperature10.1002/admi.201400019 ↗
17. Syntheses and structural understanding of a Ti-Ta alloy-based nanotubular oxide photocatalyst10.1039/C8CE00743H ↗
18. In vitro electrochemical corrosion study of coupled surgical implant materials10.1002/jbm.820170308 ↗
19. Selecting medium for corrosion testing of bioabsorbable magnesium and other metals – A critical review10.1016/j.corsci.2020.108722 ↗
20. Significance of crystallinity on the photoelectrochemical and photocatalytic activity of TiO 2 nanotube arrays10.1016/j.apsusc.2014.06.004 ↗
21. Effect of stirring on spontaneous dissolution rate of iron in sulphuric acid solutions10.1016/0013-4686(85)80170-5 ↗
22. Remarkable role of annealing time on anatase phase titania nanotubes and its photoelectrochemical response10.1016/j.electacta.2012.11.008 ↗
23. Anodization of titanium alloys for orthopedic applications10.1007/s11705-018-1759-y ↗
24. Catalyst-doped anodic TiO2 nanotubes: binder-free electrodes for (photo)electrochemical reactions10.3390/catal8110555 ↗
25. Formation of Ti-Ta based surface alloy on TiNi SMA substrate from thin films by pulsed electron-beam melting10.1088/1742-6596/830/1/012097 ↗
26. Combinatorial laser-assisted development of novel ti-ta alloys for biomedical applications
27. An eco-friendly low-temperature synthetic approach towards micro-pebble-structured GO@SrTiO3 nanocomposites for the detection of 2,4,6-trichlorophenol in environmental samples10.1007/s00604-021-04729-w ↗
28. Resistive switching characteristics of electrochemically anodized sub-stoichiometric Ti6O phase
29. Transparent rutile TiO2 films prepared by thermal oxidation of sputtered Ti on FTO glass10.1039/c8pp00313k ↗
30. Neutron diffraction investigation of ordered structures in the titanium-oxygen system10.1007/BF03038386 ↗
31. Formation of nanotubes on commercially pure titanium at high potentials (=10 V) and their electrochemical response
32. First experimental evidence of oxygen ordering in dilute titanium-oxygen alloys10.1080/21663831.2022.2057202 ↗
33. Observation using synchrotron X-ray diffraction of the crystallographic evolution of α-titanium after oxygen diffusion10.1080/09500839.2015.1014876 ↗
34. Synthesis of Ti6Al4V/SrFHA composites by microwave-assisted liquid phase deposition and calcination10.3390/ma15186206 ↗
35. Predicting the structure and stability of titanium oxide electrides
36. Electrides: a review10.1039/D0TC01165G ↗
37. Advances in materials and applications of inorganic electrides10.1021/acs.chemrev.0c01071 ↗
38. V. PAVATE, K.J. HANSEN, G. Mori, M. NARASIMHAN, S. RAMASWAMI, J. NULMAN, Sputtering Target, WO1999027150, 1999. 〈https://patents.google.com/patent/WO1999027150A9/en〉.Vikram Pavate,Keith J HansenGlen MoriMurali NarasimhanSeshadri RamaswamiJaim Nulman.
39. Corrosion behavior and conductivity of TiNb and TiNbN coated steel for metallic bipolar plates10.3390/app9122568 ↗
40. Role of water content in anodization of titanium to fabricate TiO 2 nanotubes and its properties10.1109/ICANMEET.2013.6609302 ↗
41. Enhancement in hydrogen generation using bamboo like TiO2 nanotubes fabricated by a modified two-step anodization technique10.1016/j.renene.2014.12.038 ↗
42. Ideal hexagonal order: formation of self-organized anodic oxide nanotubes and nanopores on a Ti–35Ta alloy10.1149/1.3490424 ↗
43. Effect of anodization on the surface characteristics and electrochemical behaviour of zirconium in artificial saliva10.1016/j.msec.2016.01.079 ↗
44. Effect of duty cycle on the crystallinity pore size surface roughness and corrosion resistance of the anodized surface on titanium10.1016/j.surfcoat.2015.07.020 ↗
45. Effect of anodizing on surface integrity of grade 4 titanium for biomedical applications10.1016/j.surfcoat.2016.12.038 ↗
46. PEDOT/FHA nanocomposite coatings on newly developed Ti-Nb-Zr implants: biocompatibility and surface protection against corrosion and bacterial infections10.1016/j.msec.2019.01.012 ↗
47. The evaluation of the impact of titania nanotube covers morphology and crystal phase on their biological properties10.1007/s10856-015-5495-2 ↗
48. Fabrication and characterization of anodic oxide nanotubes on TiNb alloys10.1007/s12598-015-0675-2 ↗
49. Zirconium-based metallic glass and zirconia coatings to inhibit bone formation on titanium10.1088/1748-605X/aba23a ↗
50. Biocompatibility study of nanocomposite titanium boron nitride (TiBN) thin films for orthopedic implant applications
51. Good interfacial lifshitz-van der waals and polar interactions in macroscopic systems10.1021/cr00088a006 ↗
52. Enhancing surface characteristics of Ti-6Al-4V for bio-implants using integrated anodization and thermal oxidation10.1039/c3tb21731k ↗
53. Surface tension and its measurement10.1016/B978-0-323-35595-7.00002-4 ↗
54. Contact angle hysteresis explained10.1021/la060254j ↗
55. Effects of surface roughness on anti-thrombogenicity of diamond-like carbon films10.1016/j.diamond.2006.12.009 ↗
56. Evaluation of erythrocytes10.1016/B978-1-4377-0173-9.00004-X ↗
57. In vitro investigation of hemocompatibility of hydrothermally treated titanium and titanium alloy surfaces10.1021/acsomega.0c00281 ↗
58. Medical device-induced thrombosis: what causes it and how can we prevent it?10.1111/jth.12961 ↗
59. and A.C. from the Li-Chong Xu, James Bauer, Christopher A. Siedlecki, H. at B.I.R.G. Department, Proteins, Platelets, and Blood Coagulation at Biomaterial Interfaces, Colloids Surfaces B Biointerfaces. 124 (2014) 49–68. https://doi.org/10.1016/j.colsurfb.2014.09.040.Proteins.10.1016/j.colsurfb.2014.09.040 ↗
60. Enhancement of bioactivity of pulsed magnetron sputtered TiC x N y with bioactive glass ( BAG) incorporated polycaprolactone ( PCL) composite scaffold10.1016/j.jallcom.2015.06.250 ↗
61. Systematically evaluate the physicochemical property and hemocompatibility of phase dependent TiO2 on medical pure titanium10.1016/j.surfcoat.2020.126501 ↗
62. Corrosion behavior of titanium boride composite coating fabricated on commercially pure titanium in Ringer’s solution for bioimplant applications10.1016/j.msec.2014.12.002 ↗
63. Corrosion behaviour of Ti6Al4V ELI nanotubes for biomedical applications10.1016/j.jmrt.2019.09.023 ↗
64. Corrosion behavior of electrochemically assembled nanoporous titania for biomedical applications10.1016/j.ceramint.2012.07.013 ↗
65. Surface characterization of oxides grown on the Ti-13Nb-13Zr alloy and their corrosion protection10.1016/j.corsci.2013.02.007 ↗
66. Structural characterization and electrochemical behavior of a laser-sintered porous Ti-10Mo alloy10.1016/j.corsci.2012.10.036 ↗
67. Enhanced corrosion resistance of the surface modified Ti-13Nb-13Zr alloy by ultrasonic shot peening10.1016/j.corsci.2021.109597 ↗
68. Deviation from the polarization resistance due to non-linearity I - theoretical formulation10.1016/S0022-0728(97)00213-1 ↗
69. Effect of fluoride on the corrosion behavior of Ti and Ti6Al4V dental implants coupled with different superstructures10.1563/AAID-JOI-D-09-00084 ↗
70. Determination of calcium/phosphorus atomic ratio of calcium phosphate apatites using x-ray diffractometry10.1111/j.1151-2916.2001.tb00663.x ↗
71. Ultrasound-mediated deposition and cytocompatibility of apatite-like coatings on magnesium alloys10.1016/j.surfcoat.2018.03.100 ↗
72. The influence of Ca/P ratio on the properties of hydroxyapatite bioceramics10.1117/12.779890 ↗
73. Corrosion behaviour of biomedical β-titanium alloys with the surface-modified by chemical etching and electrochemical methods