journal article·2015-11Open access

Electrochemical behavior of bioactive coatings on cp-Ti surface for dental application

Isabella da Silva Vieira Marques, Valentim Adelino Ricardo Barão, Nilson Cristino da Cruz, Judy Chia-Chun Yuan, Marcelo Ferraz Mesquita, Antonio Pedro Ricomini-Filho, Cortino Sukotjo, Mathew T. Mathew

Corrosion Science· Volume 100

Abstract

The surface characteristics and electrochemical properties of bioactive coatings produced by plasma electrolytic oxidation (PEO) with calcium, phosphorous, silicon and silver on commercially pure titanium were evaluated. PEO treatment produced a porous oxide layer, which improved the surface topography, and enriched the surface chemistry with bioactive elements, responsible for mimicking bone surface. The surfaces with higher calcium concentration presented antibacterial and biocompability properties with better responses for corrosion and barrier properties, due to the presence of rutile crystalline structure. PEO may be a promising surface treatment option to improve the electrochemical behavior of dental implants mitigating treatment failures.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Plasma electrolytic oxidation coatings on γTiAl alloy for potential biomedical applications10.1002/jbm.b.33079 ↗
2. Surface characteristics and bioactivity of an anodized titanium surface10.5051/jpis.2013.43.4.198 ↗
3. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
4. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH – an electrochemical study10.1111/j.1600-0501.2011.02265.x ↗
5. Saliva and dental implants10.1097/01.id.0000239320.57403.8d ↗
6. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
7. Plasma electrolytic oxidation (PEO) for production of anodised coatings on lightweight metal (Al, Mg, Ti) alloys10.1179/174591908X372482 ↗
8. Metal release from ceramic coatings for dental implants10.1016/j.dental.2013.12.011 ↗
9. Multifunctional porous titanium oxide coating with apatite forming ability and photocatalytic activity on a titanium substrate formed by plasma electrolytic oxidation10.1016/j.msec.2013.08.003 ↗
10. Oxidized, bioactive implants are rapidly and strongly integrated in bone. Part 1-experimental implants10.1111/j.1600-0501.2005.01230.x ↗
11. Osteoblast response to magnesium ion-incorporated nanoporous titanium oxide surfaces10.1111/j.1600-0501.2010.01944.x ↗
12. The relationship of surface roughness and cell response of chemical surface modification of titanium10.1007/s10856-012-4611-9 ↗
13. A novel antibacterial modification treatment of titanium capable to improve osseointegration10.5301/ijao.5000161 ↗
14. Formation and characterization of anodic titanium oxide films containing Ca and P10.1002/jbm.820290110 ↗
15. Incorporation of Ca and P on anodized titanium surface: effect of high current density10.1016/j.msec.2014.01.006 ↗
16. Preparation of ceramic coating on Ti substrate by plasma electrolytic oxidation in different electrolytes and evaluation of its corrosion resistance: part II10.1016/j.apsusc.2011.10.064 ↗
17. Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants10.1088/0022-3727/46/40/404001 ↗
18. In vivo histological response to anodized and anodized/hydrothermally treated titanium implants10.1002/jbm.b.10042 ↗
19. Investigation of the voltage and time effects on the formation of hydroxyapatite-containing titania prepared by plasma electrolytic oxidation on Ti–6Al–4V alloy and its corrosion behavior10.1016/j.apsusc.2011.03.103 ↗
20. Surface characteristics and electrochemical corrosion behavior of a pre-anodized microarc oxidation coating on titanium alloy10.1016/j.msec.2013.05.011 ↗
21. The role of lipopolysaccharide on the electrochemical behavior of titanium10.1177/0022034510396880 ↗
22. Surface characteristics and biocompatibility of sandblasted and acid-etched titanium surface modified by ultraviolet irradiation: an in vitro study10.1002/jbm.b.32727 ↗
23. H2O2/HCl and heat-treated Ti–6Al–4V stimulates pre-osteoblast proliferation and differentiation10.1016/j.tripleo.2009.05.033 ↗
24. Effect of load deflection on corrosion behavior of NiTi wire10.1177/154405910708600610 ↗
25. The bone response of oxidized bioactive and non-bioactive titanium implants10.1016/j.biomaterials.2005.04.058 ↗
26. Effect of plasma electrolytic oxidation in the solutions containing Ca, P Si, Na on the properties of titanium10.1002/jbm.b.32781 ↗
27. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown:: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition10.1016/S0142-9612(01)00131-4 ↗
28. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages10.1016/j.matchar.2006.03.020 ↗
29. Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis—a review10.1016/j.actbio.2013.10.036 ↗
30. A review on the wettability of dental implant surfaces II: biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
31. Effects of topography and composition of titanium surface oxides on osteoblast responses10.1016/j.biomaterials.2003.11.011 ↗
32. Osteoblast-like cell attachment and proliferation on turned blasted, and anodized titanium surfaces
33. Preparation and cytocompatibility of Si-incorporated nanostructured TiO2 coating10.1016/j.surfcoat.2010.03.028 ↗
34. Osteoblast-like cell adhesion on porous silicon-incorporated TiO2 coating prepared by micro-arc oxidation10.1002/jbm.b.31804 ↗
35. Implant osseointegration and the role of microroughness and nanostructures: lessons for spine implants10.1016/j.actbio.2014.03.037 ↗
36. Backgrounds of antibiotic-loaded bone cement and prosthesis-related infection10.1016/S0142-9612(03)00554-4 ↗
37. An electron microscopical study on the growth of TiO2–Ag antibacterial coatings on Ti6Al7Nb biomedical alloy10.1016/j.actbio.2011.02.037 ↗
38. The antimicrobial efficacy of polyamide 6/silver-nano- and microcomposites10.1016/j.matchemphys.2007.09.002 ↗
39. An exploratory study of the corrosion of Mg alloys during interrupted salt spray testing10.1016/j.corsci.2009.03.014 ↗
40. Measurement of the corrosion rate of magnesium alloys using Tafel extrapolation10.1016/j.corsci.2009.10.016 ↗
41. Polypyrrole nanowire/TiO2 nanotube nanocomposites as photoanodes for photocathodic protection of Ti substrate and 304 stainless steel under visible light10.1016/j.corsci.2015.05.059 ↗
42. Fabrication and corrosion resistance of a hydrophobic micro-arc oxidation coating on AZ31 Mg alloy10.1016/j.corsci.2014.10.041 ↗
43. Preparation of titanium oxide and hydroxyapatite on Ti–6Al–4V alloy surface and electrochemical behaviour in bio-simulated fluid solution10.1016/j.corsci.2013.11.059 ↗
44. Electrochemical study of growth behaviour of plasma electrolytic oxidation coating on Ti6Al4V: effects of the additive10.1016/j.corsci.2010.06.017 ↗
45. Micro-arc oxidization of a novel Mg–1Ca alloy in three alkaline KF electrolytes: corrosion resistance and cytotoxicity10.1016/j.apsusc.2013.11.038 ↗
46. Microstructure and corrosion resistance of modified 2024 Al alloy using surface mechanical attrition treatment combined with microarc oxidation process10.1016/j.corsci.2010.09.061 ↗