journal article·2015-06

Selective laser sintered porous Ti–(4–10)Mo alloys for biomedical applications: Structural characteristics, mechanical properties and corrosion behaviour

Fangxia Xie, Xueming He, Yanming Lv, Meiping Wu, Xinbo He, Xuanhui Qu

Corrosion Science· Volume 95
Publisher page

Abstract

Abstract Porous Ti–(4–10)Mo alloys (4, 6, 8 and 10 wt.% Mo) were prepared from elemental metallic powders by indirect selective laser sintering. This investigation focuses on porous, microstructural, mechanical and electrochemical properties to clarify their interrelation. The results demonstrated that lower porosity level and higher β content are beneficial to improved mechanical behaviour, while smaller pore size and lower porosity to better corrosion resistance. Namely, structural characteristics influence mechanical properties, whereas electrochemical behaviour is dominated mainly by porous features. The unique porous structure combined with suitable mechanical properties and high corrosion resistance make porous Ti–Mo alloys prospective biomaterials for orthopedic implants.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Additive Manufacturing Materials and Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (62)

Show source-provided references
1. Beta-type Ti–Mo–Si ternary alloys designed for biomedical applications10.1016/j.matdes.2011.08.012 ↗
2. Characterization of air-formed surface oxide film on Ti–29Nb–13Ta–4.6Zr alloy surface using XPS and AES10.1016/j.corsci.2008.06.002 ↗
3. In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy10.1007/s10856-010-4057-x ↗
4. Mechanical properties-graded Ti alloy implants for orthopedic applications
5. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
6. The bone tissue compatibility of a new Ti–Nb–Sn alloy with a low Young’s modulus10.1016/j.actbio.2011.02.008 ↗
7. Mechanical properties and microstructures of β Ti–25Nb–11Sn ternary alloy for biomedical applications10.1016/j.msec.2012.12.072 ↗
8. Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties10.1016/j.actbio.2010.01.046 ↗
9. Quaternary Ti–20Nb–10Zr–5Ta alloy during immersion in simulated physiological solutions: formation of layers, dissolution and biocompatibility10.1007/s10856-014-5144-1 ↗
10. Nanostructured Ti-based multi-component alloys with potential for biomedical applications10.1016/S0142-9612(03)00440-X ↗
11. Corrosion behavior of Ti–Mo alloys cold rolled and heat treated10.1016/j.jallcom.2011.03.045 ↗
12. Molybdenum: an essential trace element in human nutrition10.1146/annurev.nu.08.070188.002153 ↗
13. Effect of Mo content on electrochemical behaviour of TiMo alloys for dental applications10.1002/maco.201005761 ↗
14. Selective laser sintering: a qualitative and objective approach10.1007/s11837-003-0175-y ↗
15. Manufacturing near dense metal parts via indirect selective laser sintering combined with isostatic pressing10.1007/s00339-007-4159-6 ↗
16. On the role of magnesium and nitrogen in the infiltration of aluminium by aluminium for rapid prototyping applications10.1016/j.actamat.2004.03.004 ↗
17. Selective laser sintering of biocompatible polymers for applications in tissue engineering
18. Selective laser sintering of hydroxyapatite/poly-ε-caprolactone scaffolds10.1016/j.actbio.2009.07.018 ↗
19. Structure and properties of cast binary Ti–Mo alloys10.1016/S0142-9612(99)00114-3 ↗
20. Optimization of strength, ductility and corrosion resistance in Ti–Mo base alloys by controlling Mo equivalency and bond order10.2320/matertrans.M2011124 ↗
21. Electrochemical behavior of Ti–Mo alloys applied as biomaterial10.1016/j.corsci.2007.09.009 ↗
22. Corrosion behaviour of Ti–15Mo alloy for dental implant applications10.1016/j.jdent.2008.03.007 ↗
23. Repeatability of corrosion parameters for titanium–molybdenum alloys in 0.9% NaCl solution10.1016/j.jallcom.2007.10.115 ↗
24. A comparison between the corrosion characteristics of 316 stainless steel, solid titanium, and porous titanium10.1016/0010-938X(93)90021-8 ↗
25. Corrosion behaviour of porous Ti–39Nb alloy for biomedical applications10.1016/j.corsci.2013.03.007 ↗
26. The influence of pore morphology on corrosion10.1016/S0010-938X(97)00152-2 ↗
27. Stability of protective oxide films formed on a porous titanium10.1016/S0010-938X(01)00080-4 ↗
28. Corrosion behaviour of porous titanium–graphite composites designed for surgical implants10.1016/S0010-938X(99)00103-1 ↗
29. Enhanced superplasticity and strength in modified Ti–6AI–4V10.1007/BF02668895 ↗
30. Design of powder metallurgy titanium alloys and composites10.1016/j.msea.2005.10.057 ↗
31. Preparation and properties of porous Ti–10Mo alloy by selective laser sintering10.1016/j.msec.2012.11.037 ↗
32. Electrochemical corrosion behavior of Ti–24Nb–4Zr–8Sn alloy in a simulated physiological environment10.1016/j.apsusc.2011.12.096 ↗
33. Electrochemical behavior of centrifuged cast and heat treated Ti–Cu alloys for medical applications10.1016/j.electacta.2009.09.016 ↗
34. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids10.1016/j.corsci.2012.08.042 ↗
35. Characterisation and corrosion resistance of electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti–6Al–4V–1Zr alloy surface10.1016/j.corsci.2010.11.033 ↗
36. Composition and processing effects on the electrochemical characteristics of biomedical titanium alloys10.1016/j.corsci.2014.02.017 ↗
37. Characterization of passive films on shape memory stainless steels10.1016/j.corsci.2011.12.022 ↗
38. Improving corrosion resistance of Ti–6Al–4V alloy through plasma-assisted PVD deposited nitride coatings10.1016/j.corsci.2014.07.047 ↗
39. Electrochemical impedance spectroscopy characterization of passive film formed an implant Ti–6Al–7Nb alloy in Hank’s solution10.1023/B:JMSM.0000010097.86245.74 ↗
40. Evaluating electrochemical behaviour of recrystallized titanium alloys in Ringer’s solution10.1002/maco.201106185 ↗
41. Potential of ceramic materials as permanently implantable skeletal prostheses10.1002/jbm.820040309 ↗
42. Time-dependent morphology and adhesion of osteoblastic cells on titanium model surfaces featuring scale-resolved topography10.1016/j.biomaterials.2003.09.111 ↗
43. Surface-dimpled commercially pure titanium implant and bone ingrowth10.1016/S0142-9612(96)00185-8 ↗
44. Effect of surface finish on the osseointegration of laser-treated titanium alloy implants10.1016/j.biomaterials.2003.11.002 ↗
45. Pore diameter of more than 100μm is not requisite for bone ingrowth in rabbits10.1002/jbm.1069 ↗
46. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
47. Design and characterization of highly porous titanium foams with bioactive surface sintering in air10.1016/j.jallcom.2013.05.186 ↗
48. The mechanical properties of cellular solids10.1007/BF02645546 ↗
49. Preparation of porous Ti35Nb alloy and its mechanical properties under monotonic and cyclic loading10.1016/S1003-6326(09)60151-5 ↗
50. A novel water leaching and sintering process for manufacturing highly porous stainless steel10.1016/j.scriptamat.2006.03.039 ↗
51. Processing of titanium foams using magnesium spacer particles10.1016/j.scriptamat.2006.11.010 ↗
52. Highly porous open cell Ti-foam using NaCl as temporary space holder through powder metallurgy route10.1016/j.matdes.2013.01.005 ↗
53. Processing and properties of porous titanium using space holder technique10.1016/j.msea.2008.11.022 ↗
54. Processing of porous TiNi alloys using magnesium as space holder10.1016/j.jallcom.2008.11.141 ↗
55. Titanium alloys in total joint replacement-a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
56. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
57. The mechanical properties of bone
58. Corrosion behaviour of Lotus-type porous high nitrogen nickel-free stainless steels10.1016/j.corsci.2007.06.004 ↗
59. Effect of surface treatment on electrochemical behavior of CP Ti, Ti–6Al–4V and Ti–13Nb–13Zr alloys in simulated human body fluid10.1016/j.corsci.2005.06.003 ↗
60. Corrosion behaviour of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
61. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
62. Surface and electrochemical characterization of a new ternary titanium based alloy behaviour in electrolytes of varying pH10.1016/j.corsci.2013.07.026 ↗