journal article·2010-03

IR thermographic detection and characterization of hidden corrosion in metals: General analysis

S. Marinetti, V. Vavilov

Corrosion Science· Volume 52· Issue 3
Publisher page

Abstract

Principles of infrared thermographic non-destructive testing for determining hidden corrosion in metals are summarized and discussed. 1D, 2D and 3D heat conduction models are introduced to simulate thermal processes in corroded areas. In thick metals, the lateral heat dissipation is mainly responsible for significantly smoothing the temperature contrast curves. Modelling small-size corroded sites requires 3D numerical models. Numerous defects have been simulated and the inversion formulas for determining material loss have been modelled for both flash and square-pulse heating. It has been shown that corrosion characterization inaccuracy is lower than 20% in cases representing a practical interest.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Thermography and Photoacoustic Techniques · Ultrasonics and Acoustic Wave Propagation · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Quantitative thermal imaging of aircraft structures10.1117/12.204859 ↗
2. Inversion for hidden corrosion characterization: theory and applications10.1016/0017-9310(95)00126-T ↗
3. Corrosion evaluation by thermal image processing and 3D modelling10.1016/S0035-3159(98)80045-7 ↗
4. Detection of hidden corrosion in metals by using transient infrared thermography
5. S. Marinetti, P.G. Bison, E. Grinzato, 3D heat flux effects in the experimental evaluation of corrosion by IR thermography, in: Intern. Conf. Proc. “Quant. IR Thermography 6 – QIRT’02” Dubrovnik, Croatia, 2002, pp. 92–98.10.21611/qirt.2002.010 ↗
6. Boiler tube corrosion characterization with a scanning thermal line10.1117/12.421047 ↗
7. The thermal photocopier: a new concept for thermal NDT10.1117/12.541881 ↗
8. Hidden corrosion detection in thick metallic components by transient IR thermography10.1016/j.infrared.2006.06.011 ↗
9. Detection of corrosion steel under an organic coating by infrared photography10.1016/j.corsci.2003.12.001 ↗
10. ThermoCalc-6L Operation Manual, Innovation, Ltd., Russia, 2007.
11. Sensitivity analysis of classical heat conduction solutions applied to materials characterization10.1080/01457630500207477 ↗
12. Methodology of processing experimental data in transient thermal NDT10.1117/12.204852 ↗
13. Almond · 1996
14. Flash method of determining thermal diffusivity, heat capacity and thermal conductivity10.1063/1.1728417 ↗
15. Pulse phase infrared thermography10.1063/1.362662 ↗