Study of localized corrosion of 304 stainless steel under chloride solution droplets using the wire beam electrode
Source abstract
Abstract
Localized corrosion of 304 stainless steel under droplets of 1 M sodium chloride solution was investigated by the wire beam electrode (WBE) method. It was found that the current distributions were heterogeneous with isolated anodic current peaks mostly located near the edge of the droplet. During the corrosion process, the stainless steel WBE exhibited the stochastic characteristics with the disappearance of some anodic sites. In addition, stainless steel suffered more serious localized corrosion with the increase of the droplet size. The increase of the cathodic area and the three-phase boundary (TPB) length was believed to be the reason. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Initial stage of pitting corrosion of Type 304 stainless steel under thin electrolyte layers containing chloride ions10.1149/1.1992470 ↗
2. Pitting corrosion mechanism of Type 304 stainless steel under a droplet of chloride solutions10.1016/j.corsci.2006.08.016 ↗
3. Monitoring of rusting of stainless steels in marine atmospheres using electrochemical impedance technique10.1149/1.2202110 ↗
4. Pitting corrosion of bare stainless steel 304 under chloride solution droplets10.1149/1.3467850 ↗
5. Effects of particulate silica coatings on localized corrosion behavior of AISI 304SS under atmospheric corrosion conditions10.1149/1.2722535 ↗
6. Experimental methods designed for measuring corrosion in highly resistive and inhomogeneous media10.1016/j.corsci.2011.01.018 ↗
7. Electrochemical evaluation of under-deposit corrosion and its inhibition using the wire beam electrode method10.1016/j.corsci.2010.12.015 ↗
8. Wire beam electrode: a new tool for studying localised corrosion and other heterogeneous electrochemical processes10.1016/S0010-938X(98)00120-6 ↗
9. Mapping non-uniform corrosion using the wire beam electrode method. II. Crevice corrosion and crevice corrosion exemption10.1016/S0010-938X(00)00191-8 ↗
10. The influence of local glucose oxidase activity on the potential/current distribution on stainless steel: a study by the wire beam electrode method10.1016/j.electacta.2009.04.064 ↗
11. A novel device for the wire beam electrode method and its application in the ennoblement study10.1016/j.corsci.2009.03.002 ↗
12. The influence of local glucose oxidase activity on the potential/current distribution on mild steel: a study by the wire beam electrode method10.1016/j.corsci.2009.10.043 ↗
13. Heterogeneous electrochemical characteristics on biofilm/metal interface and local electrochemical techniques used for this study10.1002/maco.200905227 ↗
14. Novel corrosion experiments using the wire beam electrode. (IV). Studying localised anodic dissolution of aluminium10.1016/j.corsci.2004.11.022 ↗
15. Electrochemical studies on corrosion under a water film10.1016/0921-5093(95)80071-2 ↗
16. Modeling influence of gas/liquid/solid three-phase boundary zone on cathodic process of soil corrosion10.1016/j.electacta.2009.01.033 ↗
17. Influence of electrolyte layer thickness and pH on the initial stage of the atmospheric corrosion of iron10.1149/1.1837578 ↗
18. Effect of length of gas/liquid/solid three-phase boundary zone on cathodic and corrosion behaviour of metals10.1016/j.electacta.2008.09.017 ↗