journal article·2013-02

Structural characterization and electrochemical behavior of a laser-sintered porous Ti–10Mo alloy

F.X. Xie, X.B. He, S.L. Cao, X. Lu, X.H. Qu

Corrosion Science· Volume 67
Publisher page

Abstract

Abstract The structural and electrochemical properties of a selective laser sintered porous Ti–10Mo alloy were investigated. As the sintering temperature increases from 1100 to 1400 °C, the porosity and pore size decrease from 63% to 28% and from 178 to 56 μm, respectively. The alloy comprises major α and minor β phases at room temperature. With the decrease of porosity, the corrosion potential shifts towards positive direction and corrosion current density reduces, while the passive current density decreases and passivation range widens. The lower porosity, smaller pore size and slightly increased β phase fraction cause a superior corrosion resistance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Additive Manufacturing Materials and Processes · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
2. Characterization of air-formed surface oxide film on Ti–29Nb–13Ta–4.6Zr alloy surface using XPS and AES10.1016/j.corsci.2008.06.002 ↗
3. A comparison of tensile properties and corrosion behavior10.1016/j.jallcom.2007.10.054 ↗
4. Titanium alloys in total joint replacement – a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
5. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
6. Recent research and development in titanium alloys for biomedical applications and healthcare goods10.1016/j.stam.2003.09.002 ↗
7. Molybdenum: an essential trace element in human nutrition10.1146/annurev.nu.08.070188.002153 ↗
8. Theoretical study of the effects of alloying elements on the strength and modulus of β-type bio-titanium alloys10.1016/S0921-5093(98)00886-7 ↗
9. Nanostructured Ti-based multi-component alloys with potential for biomedical applications10.1016/S0142-9612(03)00440-X ↗
10. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
11. Mechanical properties of porous titanium compacts prepared by powder sintering10.1016/j.scriptamat.2003.08.018 ↗
12. Characterization of Ti–6Al–4V alloy foams synthesized by space holder technique10.1016/j.msea.2011.01.008 ↗
13. Pore characteristics of porous NiTi alloy fabricated by combustion synthesis10.1016/S0925-8388(01)01382-2 ↗
14. The rapid prototyping technologies10.1108/01445150310698634 ↗
15. Selective laser sintering: a qualitative and objective approach10.1007/s11837-003-0175-y ↗
16. Selective laser sintering of biocompatible polymers for applications in tissue engineering
17. Selective laser sintering of hydroxyapatite/poly-ε-caprolactone scaffolds10.1016/j.actbio.2009.07.018 ↗
18. The effects and interactions of fabrication parameters on the properties of selective laser sintered hydroxyapatite polyamide composite biomaterials10.1108/13552541211193467 ↗
19. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
20. Characterization of different materials for corrosion resistance under simulated body fluid conditions10.1016/S1044-5803(02)00320-0 ↗
21. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
22. Corrosion behaviour of porous titanium–graphite composites designed for surgical implants10.1016/S0010-938X(99)00103-1 ↗
23. Structure and properties of cast binary Ti–Mo alloys10.1016/S0142-9612(99)00114-3 ↗
24. Development of Ti–Mo alloys for biomedical applications: microstructure and electrochemical characterization10.1016/j.msea.2006.11.061 ↗
25. Electrochemical stability and corrosion resistance of Ti–Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
26. Electrochemical behavior of Ti–Mo alloys applied as biomaterial10.1016/j.corsci.2007.09.009 ↗
27. Repeatability of corrosion parameters for titanium–molybdenum alloys in 0.9% NaCl solution10.1016/j.jallcom.2007.10.115 ↗
28. A study on corrosion resistance of the Ti–10Mo experimental alloy after different processing methods10.1016/j.msec.2004.08.013 ↗
29. Processing and biocompatibility evaluation of laser processed porous titanium10.1016/j.actbio.2007.05.009 ↗
30. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
31. Low stiffness porous Ti structures for load-bearing implants10.1016/j.actbio.2007.03.008 ↗
32. Review: titanium and titanium alloy applications in medicine10.1504/IJNBM.2007.016517 ↗
33. Design of powder metallurgy titanium alloys and composites10.1016/j.msea.2005.10.057 ↗
34. The influence of pore morphology on corrosion10.1016/S0010-938X(97)00152-2 ↗
35. The influence of porosity on corrosion characteristics of porous NiTi alloy in simulated body fluid10.1016/S0167-577X(02)00809-1 ↗
36. Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids10.1016/j.corsci.2012.08.042 ↗
37. Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids10.1016/j.corsci.2009.08.014 ↗
38. Electrochemical corrosion behavior of biomedical Ti–22Nb and Ti–22Nb–6Zr alloys in saline medium10.1002/maco.200805173 ↗
39. In vitro corrosion behaviour of Ti–Nb–Sn shape memory alloys in Ringer’s physiological solution10.1007/s10856-012-4560-3 ↗
40. Characterization of passive films on shape memory stainless steels10.1016/j.corsci.2011.12.022 ↗
41. In vitro corrosion behaviour of Ti–5Al–2Nb–1Ta alloy in Hank’s solution10.1002/maco.200604001 ↗
42. Evaluating electrochemical behaviour of recrystallized titanium alloys in Ringer’s solution10.1002/maco.201106185 ↗
43. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25 and 37°C10.1016/j.corsci.2009.06.035 ↗
44. Effect of dendritic arm spacing on mechanical properties and corrosion resistance of Al 9 wt pct Si and Zn 27 wt pct Al alloys10.1007/BF02586225 ↗
45. The roles of macrosegregation and of dendritic array spacings on the electrochemical behavior of an Al-4.5wt.% Cu alloy10.1016/j.electacta.2006.10.004 ↗
46. Electrochemical impedance spectroscopy characterization of passive film formed an implant Ti–6Al–7Nb alloy in Hank’s solution10.1023/B:JMSM.0000010097.86245.74 ↗
47. Corrosion behaviour of Ti–15Mo alloy for dental implant applications10.1016/j.jdent.2008.03.007 ↗
48. Evaluation of anodized aluminum surfaces with electrochemical impedance spectroscopy10.1149/1.2095786 ↗
49. Corrosion behaviour of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
50. Effects of Zr content on microstructure and corrosion resistance of Ti–30Nb–Zr casting alloys for biomedical applications10.1016/j.electacta.2007.10.060 ↗