Influence of fluoride ion on the electrochemical behaviour of β-Ti alloy for dental implant application
Source abstract
Abstract
The corrosion behaviour of Ti–15Mo alloy in 0.15 M NaCl containing 0.01, 0.03, 0.06 and 0.5 M NaF is evaluated and its protective ability is compared with that of CP-Ti and Ti–6Al–4V alloy, to ascertain their suitability for dental implant application. The steady state current density of CP-Ti and, Ti–15Mo and Ti–6Al–4V alloys in 0.15 M NaCl containing 0.03 M NaF at 200 mV vs. SCE is found to be 1, 2 and 6 μA/cm2, respectively, which indicate that all of them could offer a better corrosion resistance in the potential range that could exists in the oral environment.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Chemical and electrochemical aspects of the biocompatibility of titanium and its alloys
2. Titanium and titanium alloys
3. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
4. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells10.3233/BME-1996-6202 ↗
5. Effects of aluminium and other cations on the structure of brain and liver chromatin10.1021/bi00435a043 ↗
6. Aluminum neurotoxicity in the rat brain10.1142/S0129083592000531 ↗
7. Structure and properties of cast binary Ti–Mo alloys10.1016/S0142-9612(99)00114-3 ↗
8. Corrosion of bio implants10.1007/BF02706450 ↗
9. Corrosion degradation and prevention by surface modification of biometallic materials10.1007/s10856-006-0016-y ↗
10. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
11. Nucleation of corrosion pits in Ringer’s solution containing bovine serum10.1016/j.corsci.2007.05.018 ↗
12. Comparative effect of grain size and texture on the corrosion behaviour of commercially pure titanium processed by equal channel angular pressing10.1016/j.corsci.2009.08.017 ↗
13. Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum10.1016/j.corsci.2004.09.003 ↗
14. Corrosion behaviour of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
15. Electrochemical characterization of β-Ti alloy in Ringer’s solution for implant application10.1016/j.jallcom.2009.01.036 ↗
16. Corrosion behaviour of Ti–15Mo alloy for dental implant applications10.1016/j.jdent.2008.03.007 ↗
17. Thermal oxidation of CP-Ti: evaluation of characteristics and corrosion resistance as a function of treatment time10.1016/j.msec.2009.03.007 ↗
18. Effects of Ti/TiN multilayer on corrosion resistance of nickel–titanium orthodontic brackets in artificial saliva10.1016/j.corsci.2007.03.041 ↗
19. Electrochemical stability of anodic titanium oxide films grown at potentials higher than 3V in a simulated physiological solution10.1016/j.corsci.2006.08.010 ↗
20. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
21. Serum effect on the electrochemical behaviour of titanium, Ti6Al4V and Ti6Al7Nb alloys in sulphuric acid and sodium hydroxide10.1016/j.corsci.2004.01.005 ↗
22. Susceptibility to delayed fracture of alpha–beta titanium alloy in fluoride solutions10.1016/j.corsci.2004.08.007 ↗
23. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions10.4012/dmj.20.305 ↗
24. Effects of fluoride and albumin concentration on the corrosion behavior of Ti–6Al–4V alloy10.1016/S0142-9612(02)00315-0 ↗
25. Critical evaluation of the composition and use of topical fluorides10.1177/00220345900690S154 ↗
26. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments10.1016/j.biomaterials.2004.07.022 ↗
27. Corrosion behavior of a new titanium alloy for dental implant applications in fluoride media10.1016/j.matchemphys.2004.03.019 ↗
28. Structure and properties of cast binary Ti–Mo alloys10.1016/S0142-9612(99)00114-3 ↗
29. Microstructural evolution and strengthening mechanisms in Ti–Nb–Zr–Ta, Ti–Mo–Zr–Fe and Ti–15Mo biocompatible alloys10.1016/j.msec.2004.12.013 ↗
30. A comparison of tensile properties and corrosion behavior of cast Ti–7.5Mo with c.p. Ti, Ti–15Mo and Ti–6Al–4V alloys10.1016/j.jallcom.2007.10.054 ↗
31. Development of Ti–Mo alloys for biomedical applications: microstructure and electrochemical characterization10.1016/j.msea.2006.11.061 ↗
32. Electrochemical behavior of Ti–Mo alloys applied as biomaterial10.1016/j.corsci.2007.09.009 ↗
33. Electrochemical stability and corrosion resistance of Ti–Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
34. Repeatability of corrosion parameters for titanium–molybdenum alloys in 0.9% NaCl solution10.1016/j.jallcom.2007.10.115 ↗
35. A study on corrosion resistance of the Ti–10Mo experimental alloy after different processing methods10.1016/j.msec.2004.08.013 ↗
36. Effect of commercial mouthwashes on the corrosion resistance of Ti–10Mo experimental alloy10.1007/s10856-006-0674-9 ↗
37. Study of Ti–6A1–4V biomaterial using electrochemistry and XPS techniques10.1590/S0100-40422002000100003 ↗
38. Fretting corrosion behaviour of thermally oxidized CP-Ti in Ringer’s solution10.1016/j.corsci.2009.10.029 ↗
39. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in ionorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
40. Properties of passive film formed on CP titanium, Ti–6Al–4V and Ti–13.4Al–29Nb alloys in simulated body conditions10.1016/j.intermet.2004.10.001 ↗
41. Corrosion of alloys used in dentistry: a review10.1016/j.msea.2006.05.003 ↗
42. Martensitic transformations in Ti–Mo alloys10.1007/BF00772735 ↗
43. Bania · 1993
44. Effects of fluorides on titanium and other dental alloys in dentistry10.1016/S0142-9612(97)00179-8 ↗
45. Effect of acidic fluoride solution on β-titanium alloy wire10.1002/jbm.b.30212 ↗