journal article·2011-05

Effects of flow, brass location, tube materials and temperature on corrosion of brass plumbing devices

Emily Sarver, Marc Edwards

Corrosion Science· Volume 53· Issue 5
Publisher page

Abstract

Abstract Effects of plumbing-specific installation factors on brass corrosion were investigated in a series of pipe-loop experiments. Increased flow velocity increased corrosion rates, but did not affect corrosion type. The presence of copper tubing in the plumbing system increased selectivity of brass corrosion for zinc, unless a galvanic connection was made between copper and brass, in which case corrosion became more uniform and was accelerated. Plastic tubing allowed oxidant (i.e., free chlorine) to persist in water, increasing brass exposure. Additionally, hot water significantly increased lead leaching from brass. These findings may inform future investigations into brass corrosion issues and plumbing designs.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Water Treatment and Disinfection · Corrosion Behavior and Inhibition · Recycling and Waste Management Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Review of brass dezincification corrosion in potable water systems10.1515/CORRREV.2010.28.3-4.155 ↗
2. D. Nicholas, Dezincification of Brass in potable waters, Urban Water Research Association of Australia, Research Report No. 84, (1994).
3. Trace metal contamination from Brass fittings10.1002/j.1551-8833.1988.tb03134.x ↗
4. D. Lytle, M. Schock, Stagnation Time, Composition, pH and Orthophosphate Effects on Metal Leaching from Brass, US EPA, EPA/600/R-96/103, (1996).
5. Brass corrosion and the LCR monitoring program10.1002/j.1551-8833.2001.tb09128.x ↗
6. Critical evaluation of the NSF 61 Section 9 test water for lead10.1002/j.1551-8833.2007.tb08035.x ↗
7. Sundberg · 2006
8. Corrosion by potable waters in building systems
9. M. Massey, Covington residents sue over corrosive plumbing system, in: Louisiana Record (Online), 2010, available: (cited September 20, 2010).
10. Safe drinking water act amendments of 1986, Public Law No. 99-339, Dec. (1986).
11. An assessment of lead exposure potential from residential cutoff valves
12. Reducing lead exposure from drinking water: recent history and current status10.1177/003335490512000317 ↗
13. Y. Zhang, “Dezincification and brass lead leaching in premise plumbing systems: effects of alloy, physical conditions and water chemistry,” Master’s Thesis. Virginia Polytechnic Institute and State University (2009).
14. The Mechanism of Dezincification and the Effect of Arsenic10.1179/bcj.1965.1.1.9 ↗
15. D. Davies, A Note on the Dezincification of brass and the inhibiting effect of elemental additions, Copper Development Association, Technical Report, (2003).
16. M. Turner, The influence of water composition on the dezincification of duplex Brass fittings, in: Proceedings of the Society for Water Treatment and Examination, (1961) 162–174.
17. Corrosion and Dezincification of Brasses in Water10.1520/JTE11374J ↗
18. LaQue · 1963
19. Corrosion of alloys
20. G. Bengough, R. May, Seventh report to the corrosion research committee, J. of the Institute of Metals, 32 (924) 96–296.
21. Effects of softened water on equipment10.1002/j.1551-8833.1956.tb15424.x ↗
22. The effects of flow on dezincification
23. V. Lucey, Relationship between water composition and dezincification of duplex brass, in: Proceedings of BNF’s Seminar on Dezincification in Brass Fittings for Water Services, Copenhagen, (1973).
24. E. Sarver, K. Dodson, P. Scardina, R. Lattyak-Slabaugh, M. Edwards, copper pitting in chlorinated, high pH potable waters, J. Am. Water Works Assoc., (2011, in press).10.1002/j.1551-8833.2011.tb11423.x ↗
25. 2005
26. National Primary Drinking Water Regulations, 40 CFR, Part 141.54. 63 FR 69465, Dec. (1998).
27. Corrosion and leaching of copper tubing exposed to chlorinated drinking water10.1023/A:1005060206953 ↗
28. R. Oliphant, M. Schock. Copper Alloys and Solder, in: Internal Corrosion of Water Distribution Systems, American Water Works Association, Denver, CO., 1996, 269-312.
29. Dezincification of water supply fittings
30. Lead contamination in Perth drinking water
31. AWWA, APHA, and WEF, Standard Methods, 20th ed., American Public Health Association, (1998).
32. B. Eckhouse, M. Trask, As Justice’s Wheels Grind, Frustration Over Failure-prone Plumbing Grows (Online), The Las Vegas Sun, 2010, available: 〈http://www.lasvegassun.com/news/2008/mar/23/31000-homes-county-may-need-7000-worth-new-plumbin/〉 (cited March 23, 2008).
33. 2009
34. California State Legislature, California Plumbing Code, Title 24, Part 5. Sacramento, California, (2007).
35. Paige · 1992