Stress corrosion crack initiation of alloy 600 in PWR primary water
Source abstract
Abstract
Abstract Stress corrosion crack (SCC) initiation of three mill-annealed alloy 600 heats in simulated pressurized water reactor primary water has been investigated using constant load tests equipped with in-situ direct current potential drop (DCPD) measurement capabilities. SCC initiation times were greatly reduced by a small amount of cold work. Shallow intergranular attack and/or cracks were found on most high-energy grain boundaries intersecting the surface with only a small fraction evolving into larger cracks and intergranular SCC growth. Crack depth profiles were measured and related to DCPD-detected initiation response. Processes controlling the SCC initiation in mill-annealed alloy 600 are discussed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Nuclear Materials and Properties · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. The influence of the strain-rate on the stress corrosion cracking of alloy 600 in high temperature primary water10.1016/0010-938X(94)00158-3 ↗
2. IGSCC of alloy 600 in PWR primary water influence of a cold worked layer on crack initiation
3. Influence of surface condition on primary water stress corrosion cracking initiation of alloy 60010.5006/1.3290356 ↗
4. Intergranular stress corrosion cracking initiation and growth in mill-annealed Alloy 600 tubing in high-temperature caustic10.5006/1.3284878 ↗
5. SCC initiation testing of nickel-based alloys using in-situ monitored uniaxial tensile specimens
6. Detection of SCC initiation in BWR environment by electrochemical noise
7. SCC initiation testing of nickel-based alloys in high temperature water
8. SCC initiation testing of alloy 600 in high temperature water
9. Stress corrosion crack initiation measurements of alloy 600 in PWR primary water
10. Precursor corrosion damage and stress corrosion crack initiation in alloy 600 during exposure to PWR primary water
11. Testing and analyses of Davis-Besse UNS N06600 control rod drive mechanism nozzles
12. Bruemmer · 2013
13. Stress corrosion crack initiation of cold-worked alloy 600 and alloy 690 in PWR primary water
14. Behavior of short cracks in stainless steel at 288°C
15. Bruemmer · 2011 · vol. 2
16. Primary water stress corrosion cracking tests and metallurgical analysis of Davis Besse control rod drive mechanism nozzle #4
17. Scott · 2005 · 1011788
18. Discontinuous creep in short-range order alloys10.1016/0025-5416(82)90030-1 ↗
19. An incompatible singular elastic element for two- and three-dimensional crack problems10.1007/BF00018917 ↗
20. Elliptical-arc surface cracks in round bars10.1111/j.1460-2695.1992.tb00039.x ↗
21. Experimental and finite element analyses on stress intensity factors of an elliptical surface crack in a circular shaft under tension and bending10.1023/B:FRAC.0000047784.23236.7d ↗
22. A critical review of stress intensity factor solutions for surface cracks in round bars subjected to tension loading10.1016/j.engfailanal.2008.06.023 ↗
23. An analysis of primary water stress corrosion cracking in PWR steam generators
24. Modelling of stress corrosion cracking initiation of Alloy 600 in primary water of PWRs
25. Crack growth rate measurements on Alloy 600 steam generator tubing in primary and hydrogenated AVT water
26. Assessment of the interaction of variables in the intergranular stress corrosion crack growth rate behavior of alloys 600, 82, and 182
27. Importance of surface preparation for corrosion control in nuclear power stations
28. Learnings from EDF investigation on SG divider plates and vessel head nozzles: evidence of prior deformation effect on stress corrosion cracking
29. Comparison of laboratory and field experience of PWSCC in alloy 182 weld metal
30. 3D analysis of surface treatment effect on the oxidation of grain boundaries in alloy 600
31. Effect of surface preparation on intergranular stress corrosion cracking of alloy 600 in hydrogenated steam10.5006/1.3279916 ↗