journal article·2008-10

Galvanic currents and corrosion rates of reinforcements measured in cells simulating different pitting areas caused by chloride attack in sodium hydroxide

C. Andrade, P. Garcés, I. Martínez

Corrosion Science· Volume 50· Issue 10
Publisher page

Abstract

Chlorides induce localized corrosion in the reinforcement. The pits formed a substantial reduction in the cross-sectional area. The smaller is the ratio between the size of the corrosion spot and the surrounding passive metal area acting as cathode, the higher is the corrosion rate or the progression in the pit depth. This, however, is not always the case. To understand well the macro or microcell behavior of the corrosion of reinforcements, this paper reports a study on the effect of decreasing sizes of anodic zones until relatively small, maintaining the size of the cathode constant. In addition, to enhance the pure anodic behavior of the corroding zone, an acidic solution was used as an anolyte. Measuring the galvanic current (Ig) and the corrosion rate (Icorr) by using zero resistance ammeter (ZRA) and polarization resistance (Rp) techniques, respectively, was crucial to differentiate the microcell contribution from that of the macrocell. The results indicate that while Ig increased as the anodic area decreased, Icorr presented a maximum for the area ratios, SA/SC = 1/3.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. The effect of macrocells between active and passive areas of steel reinforcement10.1016/0010-938X(92)90148-V ↗
2. Influence of the cathode-to-another area ratio separation distance on galvanic corrosion currents of steel in concrete containing chlorides10.1016/0008-8846(95)00094-S ↗
3. Evans · 1960
4. Area relationships in galvanic corrosion10.5006/0010-9312-27.10.436 ↗
5. Macrocell effects on potential measurements in concrete cathodic protection systems10.5006/1.3292145 ↗
6. Galvanic corrosion of steel in concrete10.4028/www.scientific.net/MSF.192-194.899 ↗
7. C. Andrade, I. Rz-Maribona, S. Feliú, J.A. González, Macrocell versus microcell corrosion of reinforcements placed in parallel, Corrosion 92. Paper No. 194
8. Quantitative measurement of corrosion rate of reinforcing steels embedded in concrete using polarization resistance measurements10.1002/maco.19780290804 ↗
9. RILEM Recommendations of TC 154-EMC: Electrochemical techniques for measuring metallic corrosion, Test methods for on site measurement of resistivity of concrete, Mater. Struct. 33 (2000).
10. Comparison of rates of general corrosion and maximum pitting penetration of concrete embedded steel reinforcement10.1016/0008-8846(95)00006-2 ↗
11. Patch repairs on reinforced concrete structures – model investigations on the required size and practical consequences10.1016/j.cemconcomp.2006.05.016 ↗
12. S. Jäggi, H. Böhni, B. Elsener, Macrocell Corrosion of Steel in Concrete – Experiments and Numerical Modelling, Eurocorr 2001 Riva di Garda, Italy, Publ. Associazione Italiana Metallurgia (AIM), Milan, 2001.
13. An equivalent electrical circuit of macrocell activity in facing electrodes embedded in cement mortar10.1016/0010-938X(94)90140-6 ↗
14. Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure Part 2. Laboratory electrochemical testing of sensors in concrete10.1016/j.cemconres.2003.11.027 ↗
15. Comparison of the polarization resistance technique to the macrocell corrosion technique. ASTM STP 1065, corrosion rates of steel in concrete
16. Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structures. Part 1. Laboratory tests to correlate galvanic current with actual damage10.1016/S0008-8846(03)00226-6 ↗
17. Macrocell sensor systems for monitoring of the corrosion risk of the reinforcement in concrete structures10.1016/S0963-8695(01)00011-1 ↗
18. Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar10.1016/S0008-8846(00)00265-9 ↗