Hydrogen embrittlement risk of high strength galvanized steel in contact with alkaline media
Source abstract
Abstract
The critical conditions for hydrogenembrittlement (HE) risk of highstrengthgalvanizedsteel (HSGS) wires and tendons exposed to alkaline concrete pore solutions have been evaluated by means of electrochemical and mechanical testing. There is a relationship between the hydrogenembrittlementrisk in HSGS and the length of hydrogen evolution process in alkalinemedia. The galvanizedsteel suffers anodic dissolution simultaneously to the hydrogen evolution which does not stop until the passivation process is completed. HSGS wires exposed to a very highalkalinemedia have showed HE risk with loss in mechanical properties only if long periods with hydrogen evolution process take place with a simultaneous intensive galvanized coating reduction.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Des aciers à haute résistance, galvanisés, utilisables comme armatures de béton précontraint10.1007/BF02478857 ↗
2. Investigations on the hydrogen-induced brittle fracture of galvanized prestressed steels in concrete10.1002/srin.197603788 ↗
3. Investigations on the influence of zinc on the corrosion behaviour of high strength steels10.1002/maco.19790300904 ↗
4. M. Brachet, M.A. Raharinaivo, Use of high strength hot-dip galvanized steel as prestressing tendons, in: FIP (Ed.), Proceedings of the 3rd Symposium of Federation International de la Précontrainte (FIP), Madrid, 1981, pp. 1–44.
5. A.R. Cook, High strength galvanized steel wire in prestressed concrete. Galvanized reinforcement for concrete-II, in: ILZRO (Ed.): proceedings of the 12th international galvanizing conference, Paris, 1979, pp. 91–101.
6. Hydrogen induced stress corrosion cracking of non galvanized and galvanized construction steels10.1002/maco.19860370606 ↗
7. Performance of 40-year old concrete bridge with embedded prestressed galvanized strands
8. A. Raharinaivo, Experimental Use of Galvanized Prestressing Steel for Stiffening the Roquemaure Bridge (France) by Additional Prestressing, in: Galvanized Reinforcement for Concrete – II, ILZRO report, Madrid, 1981, pp. 1–29.
9. Electrochemical studies on corrosion of a range of zinc alloy coated steel in alkaline solutions10.1016/0257-8972(95)02428-X ↗
10. C. Andrade, C. Alonso, Electrochemical aspects of galvanized reinforcement corrosion, in: S.R. Yeomans (Ed.), Galvanised steel reinforcement in concrete, Oxford, 2004, pp. 111–144.10.1016/B978-008044511-3/50020-7 ↗
11. Yeomans · 2004
12. Corrosion of metals in contact with mineral building materials
13. Effect of coating structure on corrosion kinetics of galvanized reinforcement in concrete10.1007/BF02473980 ↗
14. The mechanism of steel corrosion in concrete structures
15. Revisión sobre el comportamiento de las armaduras galvanizadas en el hormigón
16. Treadway · 1980
17. Corrosion behaviour in concrete of three differently galvanized steel bars10.1016/j.cemconcomp.2006.01.011 ↗
18. Pourbaix · 1996
19. Hydrogen embrittlement steel submitted to slow strain rate studied by nuclear resonance reaction analysis and neutron diffraction10.1016/j.nimb.2007.03.084 ↗
20. Einfluß von zinkoxyd auf das erstarren und erhärtenvon portlandzementen
21. SEM study of the corrosion products of Galvanized Reinforcements immersed in Solutions in the pH Range 12.6 to 13.610.1179/000705984798273524 ↗
22. Quantitative measurements of corrosion rate of reinforcing steels embedded in concrete using polarisation resistance measurements10.1002/maco.19780290804 ↗
23. The behaviour of galvanized steel in chloride-containing alkaline solutions. I. The influence of the cation10.1016/0010-938X(90)90046-8 ↗
24. Effect of surface condition on the initial corrosion of galvanized reinforcing steel embedded in concrete10.1016/j.corsci.2008.06.035 ↗
25. Gaillet, L. Blondelle, Rapport d’étude nouveaux alliages de galvanisation, Lab. Central des Ponts et Chaussées, Internal Reference, GR000015363, Paris, 2005, p. 29.
26. The metallurgy of zinc-coated steel10.1016/S0079-6425(98)00006-1 ↗
27. F. Porter, Zinc handbook: properties processing and use design, in: Marcel Decker. Inc., New York, 1991, p. 629.10.1201/9781482276947 ↗
28. American Society for Metals, Handbook 13: Corrosion in: ASM International, Materials Park, USA, 1987, pp. 432-445.
29. Galvanizing characteristics of different types of steel
30. Corrosion of galvanized steel in dilute Ca(OH)2 solutions (pH 11.1–12.6)10.1179/000705987798271505 ↗
31. Corrosion of galvanized steel reinforcements in alkaline solutions. Part 2: SEM study and identification of corrosion products10.1179/000705987798271749 ↗
32. Corrosion of galvanized steel reinforcements in alkaline solutions. Part 1: Electrochemical results10.1179/000705987798271631 ↗
33. The effects of an intermetallic coating on the stress corrosion cracking behaviour of a hot-dip galvanized steel10.1016/S0257-8972(01)01017-9 ↗
34. Effect of galvanizing on hydrogen embrittlement of prestressing wire10.15554/pcij.07011988.146.158 ↗
35. A. Moragues, A. Macias, C. Andrade, Equilibria of chemical composition of the concrete pore solution. Part I: Comparative of synthetic and extracted solutions, Cem. Concr. Res.17 (1987) 173–182.
36. Hydrogen embrittlement susceptibility of galvanised 4135 steel in cement environment10.1016/0010-938X(93)90183-H ↗