journal article·2008-12

Corrosion mechanism of hot-dip galvanised reinforcement bar in cracked concrete

E. Sistonen, A. Cwirzen, J. Puttonen

Corrosion Science· Volume 50· Issue 12
Publisher page

Abstract

In this paper, probable corrosion mechanisms of hot-dip galvanised reinforcement bar in cracked concrete based on long-term durability tests and other studies are determined. The fist mechanism consists of a local dissolution of eta (η) and zeta (ζ) phase. In the second mechanism due to non-uniform zinc coating local dissolution of eta (η) and zeta (ζ) phase together with longitudinal and perpendicular cracking in zinc layer may lead to separation of zinc layer. In the third mechanism due to non-uniform zinc coating full dissolution of eta (η) and partial dissolution of zeta (ζ) phase together with longitudinal and perpendicular cracking in ferrite may lead to separation of zinc layer and ferrite. Corrosion rate with used cement type was decreasing. That is not dependent on concrete quality. However, concrete type has an effect on corrosion rate and moisture conditions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Yeomans · 1998
2. Performance of black, galvanized, and epoxy-coated reinforcing steel in chloride-contaminated concrete10.5006/1.3293496 ↗
3. Yeomans · 2004
4. Andrade · 1992
5. Long term exposure tests on galvanized steel in different concrete types
6. Performance variances of galvanized steel in mortar and concrete10.5006/1.3316010 ↗
7. Effect of use of galvanized steel on the durability of reinforced concrete
8. The influence of steel galvanization on rebars behaviour in concrete
9. Resistance to chlorides of galvanized rebars
10. Chloride-ion induced corrosion of galvanized and ordinary steel reinforcement in high-performance concrete10.1016/S0008-8846(98)00090-8 ↗
11. Corrosion of zinc-coated reinforcing bars in tropical humid marine environments10.1108/00035590610711697 ↗
12. Recommendations of RILEM TC-154-EMC: “electrochemical techniques for measuring metallic corrosion”. Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method10.1007/BF02483292 ↗
13. Luping · 2002
14. Corrosion of reinforced steel bars in concrete
15. J.M. Sykes, Electrochemical studies on steel in concrete, in: Materials Science Forum, vols. 192–194, 1995, pp. 833–842 (Electrochemical Methods in Corrosion Research V).10.4028/www.scientific.net/MSF.192-194.833 ↗
16. Electrochemical behaviour of 1018, 304 and 800 alloys in synthetic wastewater
17. ASTM C 1218-97, Standard Test method for Water-Soluble Chloride in Mortar and Concrete, American Society for Testing and Materials, 1997.
18. Backscattered electron imaging of cementitious microstructures: understanding and quantification10.1016/j.cemconcomp.2004.02.029 ↗
19. E. Sistonen, O.-P. Kari, P. Tukiainen, S. Huovinen, Stochastic method and Monte–Carlo simulation for predicting service life of hot-dip galvanised reinforcement, in: Marchand et al. (Eds.), 2nd International RILEM Symposium on Advances in Concrete through Science and Engineering, Quebec City, Canada, September 11–13, 2006, RILEM proceedings PRO 51 (Abstract at p. 289 and the paper number 45 is 23 pages on symposium CD-ROM proceedings).10.1617/2351580028.045 ↗
20. E. Sistonen, O.-P. Kari, P. Tukiainen, S. Huovinen, The influence of the crack width on the durability of different reinforcement bar materials, in: Toutlemonde et al. (Eds.), CONSEC’07, Concrete Under Severe Conditions: Environment and Loading, Tours, France, June 4–6, 2007. pp. 419–428.
21. Corrosion behaviour in concrete of three differently galvanized steel bars10.1016/j.cemconcomp.2006.01.011 ↗
22. Effect of Ni addition in zinc bath on formation of inhibition layer during galvannealing of hot-dip galvanized sheet steels10.1023/A:1010953505679 ↗
23. Tests on bond of galvanized rebar and concrete cured in seawater10.1061/(ASCE)0899-1561(2001)13:5(319) ↗
24. Andrade · 1995
25. E. Sistonen, S. Huovinen, The main corrosion parameters and their influence on the durability of outdoor concrete structures, nordic concrete research – research projects, in: Proceedings Nordic Concrete Research Meeting, XIX Symposium on Nordic Concrete Research and Development – A meeting place for research and practice; Norway, 2005, Sandefjord: 12 to 15.6.2005, Publication no. 33, pp. 271–273.
26. On-site measurements of corrosion rate of reinforcements10.1016/S0950-0618(00)00063-5 ↗
27. Recommendations of RILEM TC-154-EMC: “electrochemical techniques for measuring metallic corrosion”. Test methods for on-site measurement of resistivity of concrete
28. Corrosion products of galvanized rebars embedded in chloride-contaminated concrete10.5006/1.3280600 ↗
29. A. Cwirzen, Effects of the Transition Zone and aging on the Frost Damage of the High Strength Concretes, Helsinki University of Technology, Building Materials Technology, Report 17 (Dissertation), Espoo 2004, p. 190 + app. 65 p.