Tafel slopes used in monitoring of copper corrosion in a bentonite/groundwater environment
Source abstract
Abstract
The harmonic analysis, the polarization resistance, and the noise resistance methods have been applied in an effort to monitor corrosion of pure copper in a bentonite/groundwater environment with commercially available equipment. Without the need to use a reference electrode, the first method supplies not only an estimate of the corrosion rate, but also estimates of Tafel slopes required by the other methods. The recorded corrosion rate is overestimated but to a varying degree. While the recorded corrosion rates for the first two methods give quite similar values far below 3 μm/year, the electrochemical noise resistance method gives considerably higher values.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Concrete Corrosion and Durability · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. SR 97 Waste, repository design and sites, TR-99-08, Svensk Kärnbränslehantering AB, Stockholm, 1999.
2. F. King et al., Copper corrosion under expected conditions in a deep geological repository, TR-01-23, Svensk Kärnbränslehantering AB, Stockholm, 2001.
3. Experiments at the Äspö Hard Rock Laboratory, Svensk Kärnbränslehantering AB.
4. Application of harmonic analysis in the measuring technique of corrosion10.1149/1.2055062 ↗
5. Harmonic analysis of electrochemical and corrosion systems—A review10.1515/CORRREV.1999.17.5-6.383 ↗
6. Harmonic synthesis: A novel electrochemical method for corrosion rate monitoring10.1149/1.1559065 ↗
7. SmartCET® Technology—User Guide v06 04 03, InterCorr International, Inc., Houston, TX, USA.
8. Electrochemical polarization—I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
9. D.A. Eden, Electrochemical noise—The first two octaves, CORROSION/98, Paper No. 386, NACE, Houston, TX, 1998.
10. Interpretation of electrochemical noise data10.5006/1.3290350 ↗
11. B. Rosborg et al., Real-time monitoring of copper corrosion at the Äspö HRL, presentation at EUROCORR 2004, EFC event No. 266, in Nice on 12–16 September 2004.
12. Measurements of copper corrosion in the LOT project at the Äspö Hard Rock Laboratory
13. Copper corrosion—I. Thermodynamic aspects, II. Kinetic studies, III. Electrochemical theory of general corrosion, IV. The effects of saline additions10.1149/1.2425445 ↗
14. The corrosion rate of copper in a test parcel at the Äspö Hard Rock Laboratory
15. A. Brennenstuhl, Kinectrics Inc., Toronto, Canada. Private communication to G. Quirk, May 2001. First cited in Ref. [12].
16. Determination of instantaneous corrosion rates and runoff rates of copper from naturally patinated copper during continuous rain events10.1016/S0010-938X(02)00015-X ↗
17. Material characterization of ancient Indian copper10.1007/BF02704321 ↗