journal article·2020-04Open access

Tribocorrosion behaviour of bio-functionalized porous Ti surfaces obtained by two-step anodic treatment

A.I. Costa, L. Sousa, A.C. Alves, F. Toptan

Corrosion Science· Volume 166

Abstract

Abstract A bio-functionalized porous surface was obtained on Ti by a two-step anodic treatment and its corrosion and tribocorrosion behaviour were evaluated. The first-step provided macro-porosity while the second-step, a bio-functionalization process by micro-arc oxidation (MAO), provided an oxide layer (anatase + rutile) with micro-pores and bio-active elements (Ca + P). Corrosion and tribocorrosion behaviour were improved due to the protective role given by the oxide layer formed on the second-step. Tribocorrosion mechanisms for the bio-functionalized porous structures are presented.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Medical Implants Market- Global Opportunity Analysis and Industry Forecast, 2014 - 2022, (2016) 216.
2. Titanium foam scaffolds for dental applications
3. Biomedical implants: corrosion and its prevention – a review10.2174/1877610801002010040 ↗
4. Composition and modifications of dental implant surfaces10.1155/2015/527426 ↗
5. Design and fabrication of CoCrMo alloy based novel structures for load bearing implants using laser engineered net shaping10.1016/j.msec.2009.08.006 ↗
6. A super-hydrophilic coating with a macro/micro/nano triple hierarchical structure on titanium by two-step micro-arc oxidation treatment for biomedical applications10.1016/j.surfcoat.2016.12.065 ↗
7. Impact of bio-functionalization on NIH/3T3 adhesion, proliferation and osteogenic differentiation of MC3T3-E1 over highly porous titanium implant material10.1002/jbm.b.34096 ↗
8. Micro-arc oxidation enhances the blood compatibility of ultrafine-grained pure titanium10.3390/ma10121446 ↗
9. Micro-arc oxidation as a tool to develop multifunctional calcium-rich surfaces for dental implant applications10.1016/j.msec.2015.05.012 ↗
10. Review of the biocompatibility of micro-arc oxidation coated titanium alloys10.1016/j.matdes.2015.07.086 ↗
11. Surface characteristics of titanium anodized in the four different types of electrolyte10.1016/j.electacta.2007.07.067 ↗
12. Tuning anatase and rutile phase ratios and nanoscale surface features by anodization processing onto titanium substrate surfaces10.1016/j.msec.2015.08.028 ↗
13. Preparation of TiO2 layers on cp-Ti and Ti6Al4V by thermal and anodic oxidation and by sol-gel coating techniques and their characterization10.1002/jbm.1212 ↗
14. A comparison of corrosion, tribocorrosion and electrochemical impedance properties of pure Ti and Ti6Al4V alloy treated by micro-arc oxidation process10.1016/j.apsusc.2014.11.030 ↗
15. Control of the physical properties of anodic coatings obtained by plasma electrolytic oxidation on Ti6Al4V alloy10.1016/j.surfcoat.2015.10.052 ↗
16. Preparation of titanium oxide and hydroxyapatite on Ti–6Al–4V alloy surface and electrochemical behaviour in bio-simulated fluid solution10.1016/j.corsci.2013.11.059 ↗
17. Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants10.1088/0022-3727/46/40/404001 ↗
18. Tribocorrosion behavior of biofunctional titanium oxide films produced by micro-arc oxidation: synergism and mechanisms10.1016/j.jmbbm.2015.12.030 ↗
19. Understanding growth mechanisms and tribocorrosion behaviour of porous TiO2 anodic films containing calcium, phosphorous and magnesium10.1016/j.apsusc.2015.02.163 ↗
20. Effect of titania anodic formation and hydroxyapatite electrodeposition on electrochemical behaviour of Ti-6Al-4V alloy under fretting conditions for biomedical applications10.1016/j.corsci.2014.11.026 ↗
21. Tribocorrosion behavior of bio-functionalized highly porous titanium10.1016/j.jmbbm.2017.01.006 ↗
22. A facile one-step anodization treatment to prepare multi-level porous titania layer on titanium10.1016/j.matlet.2011.12.094 ↗
23. Bioactive coating with hierarchical double porous structure on titanium surface formed by two-step microarc oxidation treatment10.1016/j.surfcoat.2014.04.061 ↗
24. Conformal coating containing Ca, P, Si and Na with double-level porous surface structure on titanium formed by a three-step microarc oxidation10.1039/C4RA14685A ↗
25. Dry sliding wear behaviour of aluminum syntactic foam10.1016/j.matdes.2008.09.034 ↗
26. Characteristic of the porous 316 stainless steel for the friction element of prosthetic joint10.1016/j.wear.2007.01.119 ↗
27. Influence of porosity on dry sliding wear behavior in spray deposited Al–6Cu–Mn/SiCp composite10.1016/S0921-5093(00)01052-2 ↗
28. Pitting corrosion of titanium10.1179/000705972798323297 ↗
29. Understanding the effect of mean pore size on cell activity in collagen-glycosaminoglycan scaffolds10.4161/cam.4.3.11747 ↗
30. In vitro and in vivo biological performance of porous Ti alloys prepared by powder metallurgy10.1371/journal.pone.0196169 ↗
31. Effect of surface finish on the osseointegration of laser-treated titanium alloy implants10.1016/j.biomaterials.2003.11.002 ↗
32. In vitro and in vivo study of additive manufactured porous Ti6Al4V scaffolds for repairing bone defects10.1038/srep34072 ↗
33. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
34. The effect of mean pore size on cell attachment, proliferation and migration in collagen-glycosaminoglycan scaffolds for bone tissue engineering10.1016/j.biomaterials.2009.09.063 ↗
35. Corrosion mechanisms in titanium oxide-based films produced by anodic treatment10.1016/j.electacta.2017.03.011 ↗
36. Plasma electrolysis for surface engineering10.1016/S0257-8972(99)00441-7 ↗
37. Calcium phosphate bioceramics: a review of their history, structure, properties, coating technologies and biomedical applications10.3390/ma10040334 ↗
38. Synthesis by anodic-spark deposition of Ca- and P- containing films on pure titanium and their biological response10.1016/j.apsusc.2016.03.161 ↗
39. Calcium orthophosphates: crystallization and dissolution10.1021/cr0782574 ↗
40. In situ observation of hydroxyapatite nanocrystal formation from amorphous calcium phosphate in calcium-rich solutions10.1016/j.matchemphys.2004.12.016 ↗
41. Structure and properties of crystalline titanium oxide layers deposited by reactive pulse magnetron sputtering10.1016/j.surfcoat.2003.10.115 ↗
42. Effects of calcium-modified titanium implant surfaces on platelet activation, clot formation, and osseointegration10.1002/jbm.a.35240 ↗
43. Effect of roughness, wettability and morphology of engineered titanium surfaces on osteoblast-like cell adhesion10.1016/j.colsurfa.2009.12.017 ↗
44. A review on the wettability of dental implant surfaces II: biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
45. Corrosion and tribocorrosion behavior of Ti−TiB−TiNx in-situ hybrid composite synthesized by reactive hot pressing, J. Mech10.1016/j.jmbbm.2017.05.041 ↗
46. The effect of metal ions released from different dental implant-abutment couples on osteoblast function and secretion of bone resorbing mediators10.1016/j.jdent.2017.08.002 ↗
47. Titanium and tribology10.1108/eb053055 ↗