Evaluation of corrosion resistance and cytocompatibility of graded metal carbon film on Ti and NiTi prepared by hybrid cathodic arc/glow discharge plasma-assisted chemical vapor deposition
Source abstract
Abstract
Abstract Hybrid cathodic arc/glow discharge plasma-assisted chemical vapor deposition is used to prepare graded films on Ti and NiTi. XPS reveals the formation of a Ti and carbon graded interface between the substrate and carbon surface layer. The graded film significantly improves the corrosion resistance of Ti and NiTi in 154 mM NaCl as demonstrated by the smaller corrosion current density, larger resistance, and smaller capacitance. The graded film on NiTi shows near-capacitive impedance spectra and 14 times larger phase angle maxima at 10 5 Hz. In addition, the osteoblasts cells spread well on the graded film surface suggesting good cytocompatibility.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Corrosion Behavior and Inhibition · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (75)
Show source-provided references
1. Free radical functionalization of surfaces to prevent adverse responses to biomedical devices10.1073/pnas.1103277108 ↗
2. Graded metal carbon protein binding films prepared by hybrid cathodic arc–glow discharge plasma assisted chemical vapor deposition10.1016/j.surfcoat.2014.11.025 ↗
3. In vivo biocompatibility of a plasma-activated, coronary stent coating10.1016/j.biomaterials.2012.07.059 ↗
4. The linker-free covalent attachment of collagen to plasma immersion ion implantation treated polytetrafluoroethylene and subsequent cell-binding activity10.1016/j.biomaterials.2009.12.009 ↗
5. Biosensors for real-time in vivo measurements10.1016/j.bios.2004.12.003 ↗
6. Regioselective covalent immobilization of recombinant antibody-binding proteins A, G, and L for construction of antibody arrays10.1021/ja402447g ↗
7. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
8. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
9. Inflammatory responses to orthopaedic biomaterials in the murine air pouch10.1016/S0142-9612(01)00134-X ↗
10. Healing of complement activating Ti implants compared with non-activating Ti in rat tibia10.1016/j.actbio.2012.05.017 ↗
11. Reduced inflammatory activity of RAW 264.7 macrophages on titania nanotube modified Ti surface10.1016/j.biocel.2014.09.006 ↗
12. Improved implant osseointegration of a nanostructured titanium surface via mediation of macrophage polarization10.1016/j.biomaterials.2014.08.025 ↗
13. The effect of immobilization of heparin and bone morphogenic protein-2 (BMP-2) to titanium surfaces on inflammation and osteoblast function10.1016/j.biomaterials.2010.09.008 ↗
14. A cascade model for restenosis. A special case of atherosclerosis progression
15. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia10.1016/S0735-1097(97)00450-6 ↗
16. Sustained activation of vascular cells and leukocytes in the rabbit aorta after balloon injury10.1161/01.CIR.88.4.1788 ↗
17. Pulmonary oxygenation, central hemodynamics and glomerular-filtration following cardiopulmonary bypass with colloid or non-colloid priming solution10.3109/14017438109100583 ↗
18. Plasma modified surfaces for covalent immobilization of functional biomolecules in the absence of chemical linkers: towards better biosensors and a new generation of medical implants10.1007/s12551-010-0028-1 ↗
19. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone10.1016/j.biomaterials.2010.07.054 ↗
20. Improved adaptability of PEEK by Nb doped graphite-like carbon composite coatings for bio-tribological applications10.1016/j.surfcoat.2014.03.016 ↗
21. Properties of carbon films and their biocompatibility using in-vitro tests10.1016/S0925-9635(02)00217-0 ↗
22. Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface10.1016/S0142-9612(01)00182-X ↗
23. Diamond-like carbon coatings as biocompatible materials—an overview10.1016/S0925-9635(03)00018-9 ↗
24. In vitro studies on the effect of delaminated a-C: H film fragments on bone marrow cell cultures10.1016/j.biomaterials.2004.09.030 ↗
25. In vitro cytocompatibility evaluation of hydrogenated and unhydrogenated carbon films10.1016/j.surfcoat.2014.07.059 ↗
26. DLC coatings: effects of physical and chemical properties on biological response10.1016/j.biomaterials.2006.12.010 ↗
27. Covalent immobilisation of tropoelastin on a plasma deposited interface for enhancement of endothelialisation on metal surfaces10.1016/j.biomaterials.2008.11.009 ↗
28. Covalently bound biomimetic layers on plasma polymers with graded metallic interfaces for in vivo implants10.1002/ppap.200900045 ↗
29. Reduction of irreversible protein adsorption on solid surfaces by protein engineering for increased stability10.1074/jbc.M503665200 ↗
30. Tight-binding of albumin to glow-discharge treated polymers10.1163/156856292X00286 ↗
31. Electrochemical studies on the influence of proteins on the corrosion of implant alloys10.1016/0142-9612(88)90119-6 ↗
32. Effect of mechanical surface pretreatment on metal ion release10.1016/S0142-9612(99)00200-8 ↗
33. Electrochemical corrosion behavior of biodegradable Mg–Y–RE and Mg–Zn–Zr alloys in Ringer’s solution and simulated body fluid10.1016/j.corsci.2014.11.015 ↗
34. Thermal oxidation of titanium: evaluation of corrosion resistance as a function of cooling rate10.1016/j.matchemphys.2012.12.020 ↗
35. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidation10.1016/j.actbio.2007.03.002 ↗
36. Bioactive and electrochemical characterization of TiO2 nanotubes on titanium via anodic oxidation10.1016/j.electacta.2010.05.082 ↗
37. Surface characterization of oxides grown on the Ti–13Nb–13Zr alloy and their corrosion protection10.1016/j.corsci.2013.02.007 ↗
38. Corrosion behaviour of laser gas nitrided Ti–6Al–4V in HCl solution10.1016/j.corsci.2009.06.016 ↗
39. Electrochemical impedance spectroscopy study of the nucleation and growth of apatite on chemically treated titanium10.1021/la011877u ↗
40. Effect of surface mechanical attrition treatment of titanium using alumina balls: surface roughness, contact angle and apatite forming ability10.1007/s11706-013-0208-6 ↗
41. Electrodeposition of polypyrrole on Nitinol alloy in the presence of inhibitor ions for corrosion protection10.1016/j.corsci.2013.11.063 ↗
42. Cell response and corrosion behavior of electrodeposited diamond-like carbon films on nanostructured titanium10.1016/j.corsci.2012.09.015 ↗
43. Effects of zirconium and oxygen plasma ion implantation on the corrosion behavior of ZK60 Mg alloy in simulated body fluids10.1016/j.corsci.2013.11.044 ↗
44. Plasma modified Mg–Nd–Zn–Zr alloy with enhanced surface corrosion resistance10.1016/j.corsci.2013.09.007 ↗
45. Effects of zirconium and nitrogen plasma immersion ion implantation on the electrochemical corrosion behavior of Mg–Y–RE alloy in simulated body fluid and cell culture medium10.1016/j.corsci.2014.05.020 ↗
46. Ion implantation treatment of beads for covalent binding of molecules: application to bioethanol production using thermophilic beta-glucosidase10.1016/j.enzmictec.2013.09.012 ↗
47. Cell patterning via linker-free protein functionalization of an organic conducting polymer (polypyrrole) electrode10.1016/j.actbio.2012.03.023 ↗
48. Biofunctionalization of surfaces by energetic ion implantation: review of progress on applications in implantable biomedical devices and antibody microarrays10.1016/j.apsusc.2014.03.097 ↗
49. Enhanced antimicrobial properties, cytocompatibility, and corrosion resistance of plasma-modified biodegradable magnesium alloys10.1016/j.actbio.2013.10.012 ↗
50. Effects of silicon plasma ion implantation on electrochemical corrosion behavior of biodegradable Mg–Y–RE alloy10.1016/j.corsci.2012.11.037 ↗
51. Effects of Ti/TiN multilayer on corrosion resistance of nickel–titanium orthodontic brackets in artificial saliva10.1016/j.corsci.2007.03.041 ↗
52. In vitro corrosion inhibition on biomedical shape memory alloy by plasma-polymerized allylamine film10.1016/j.matlet.2012.08.054 ↗
53. Recent progress in filtered vacuum arc deposition10.1016/S0257-8972(96)03023-X ↗
54. Properties of tetrahedral amorphous-carbon prepared by vacuum-arc deposition10.1016/0925-9635(91)90011-X ↗
55. Control of stress and delamination in single and multi-layer carbon thin films prepared by cathodic arc and RF plasma deposition and implantation10.1016/j.surfcoat.2005.11.011 ↗
56. Raman spectroscopy study of DLC films prepared by RF plasma and filtered cathodic arc10.1016/j.surfcoat.2006.09.048 ↗
57. Structure and hardness of vacuum arc deposited multi-component nitride coatings of Ti, Zr and Nb10.1016/S0257-8972(99)00570-8 ↗
58. X-ray photoelectron spectroscopy of nano-multilayered Zr–O/Al–O coatings deposited by cathodic vacuum arc plasma10.1016/j.apsusc.2010.03.149 ↗
59. Combined influences of mechanical properties and surface roughness on the tribological properties of amorphous carbon coatings10.1016/j.wear.2004.12.032 ↗
60. Ion-implanted polytetrafluoroethylene enhances Saccharomyces cerevisiae biofilm formation for improved immobilization10.1098/rsif.2012.0347 ↗
61. Corrosion behavior of commercially pure Mg and ZM21 Mg alloy in Ringer’s solution – long term evaluation by EIS10.1016/j.corsci.2010.10.011 ↗
62. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
63. In vitro studies of biomedical magnesium alloys in a simulated physiological environment: a review10.1016/j.actbio.2010.12.004 ↗
64. Tetrahedral bonding in amorphous carbon10.1088/0034-4885/59/12/002 ↗
65. Titanium containing amorphous hydrogenated carbon films (a-C:H/Ti): surface analysis and evaluation of cellular reactions using bone marrow cell cultures in vitro10.1016/S0142-9612(99)00135-0 ↗
66. Structural and mechanical characterization of duplex multilayer coatings deposited onto H13 tool steel10.1016/S2238-7854(12)70031-5 ↗
67. A stable cathode for the aprotic Li–O2 battery10.1038/nmat3737 ↗
68. Neuville · 2014
69. Structure and corrosion resistance of Ti/TiC coatings fabricated by plasma immersion ion implantation and deposition on nickel–titanium10.1016/j.surfcoat.2012.07.063 ↗
70. Corrosion protection of 316 L stainless steel by a TiO2 nanoparticle coating prepared by sol–gel method10.1016/j.tsf.2005.05.016 ↗
71. Corrosion behavior of ZrN/Zr coated biomedical AZ91 magnesium alloy10.1016/j.surfcoat.2009.02.074 ↗
72. Corrosion resistance of ZrO2–Zr-coated biodegradable surgical magnesium alloy10.1557/JMR.2008.0040 ↗
73. Plasma modified surfaces for covalent immobilization of functional biomolecules in the absence of chemical linkers: towards better biosensors and a new generation of medical implants10.1007/s12551-010-0028-1 ↗
74. Comparison of protein surface attachment on untreated and plasma immersion ion implantation treated polystyrene: protein islands and carpet10.1021/la062722v ↗
75. Plasma-treated polyethylene surfaces for improved binding of active protein10.1002/ppap.200600182 ↗