journal article·2017-07

Understanding the effect of magnesium degradation on drug release and anti-proliferation on smooth muscle cells for magnesium-based drug eluting stents

Yongjuan Shi, Jia Pei, Lei Zhang, Byung Kook Lee, Yeonhee Yun, Jian Zhang, Zhonghua Li, Song Gu, Kinam Park, Guangyin Yuan

Corrosion Science· Volume 123
Publisher page

Abstract

Abstract To understand the possible influence of substrate degradation on the drug-loading system of magnesium alloy-based drug-eluting stents, a rapamycin drug-loading poly(lactic-co-glycolic acid) coating was prepared on Mg-Nd-Zn-Zr stents for a systematic investigation in a phosphate buffer system. Mg degradation accelerated the drug release kinetics prominently, which was mainly attributed to H2 evolution in the diffusion-controlled phase while thereafter to PLGA erosion. Although physiochemical stability of the released rapamycin was partially deteriorated by magnesium degradation, the drug-loading system on magnesium substrates exhibited a more potent long-term inhibition on smooth muscle cell proliferation in vitro as compared to drug-loaded stainless steel.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (58)

Show source-provided references
1. Second-and third-generation drug-eluting coronary stents10.1007/s00059-011-3458-z ↗
2. Paclitaxel-eluting versus uncoated stents in primary percutaneous coronary intervention10.1056/NEJMoa062598 ↗
3. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery10.1056/NEJMoa035071 ↗
4. Novel approaches to reduce restenosis10.1196/annals.1302.032 ↗
6. The road to bioabsorbable stents: reaching clinical reality?10.1007/s00270-004-0341-9 ↗
7. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn10.1002/ccd.20756 ↗
8. Control of biodegradation of biocompatable magnesium alloys10.1016/j.corsci.2007.01.001 ↗
9. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective non-randomised multicentre trial10.1016/S0140-6736(07)60853-8 ↗
10. Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial10.1016/S0140-6736(12)61765-6 ↗
11. Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial10.1016/S0140-6736(15)00447-X ↗
12. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?10.1136/heart.89.6.651 ↗
13. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human Coronary arteries10.1016/j.jcin.2008.09.015 ↗
14. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries10.1002/ccd.20727 ↗
15. Bioresorbable drug-eluting magnesium-alloy scaffold: design and feasibility in a porcine coronary model10.4244/EIJV8I12A218 ↗
16. Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis10.1583/10-3353.1 ↗
17. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby10.1002/ccd.20520 ↗
18. safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial10.1093/eurheartj/ehw196 ↗
19. Mechanisms of controlled drug release from drug-eluting stents10.1016/j.addr.2006.01.016 ↗
20. Corrosion of magnesium alloy AZ31: The influence of bicarbonate, sulphate, hydrogen phosphate and dihydrogen phosphate ions in saline solution10.1016/j.corsci.2014.05.006 ↗
21. In vitro degradation behavior and biocompatibility of Mg–Nd–Zn–Zr alloy by hydrofluoric acid treatment10.1016/j.msec.2012.08.036 ↗
22. The development of binary Mg–Ca alloys for use as biodegradable materials within bone10.1016/j.biomaterials.2007.12.021 ↗
23. The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ9110.1016/j.corsci.2013.06.019 ↗
24. Biphasic responses of human vascular smooth muscle cells to magnesium ion10.1002/jbm.a.35570 ↗
25. Combined effect of composition and surface condition on corrosion behaviour of magnesium alloys AZ31 and AZ6110.1016/j.corsci.2012.10.034 ↗
26. Assessment of localized corrosion under simulated physiological conditions of magnesium samples with heterogeneous microstructure: value of X-ray computed micro-tomography platform10.1016/j.corsci.2015.12.009 ↗
27. Nanophasic biodegradation enhances the durability and biocompatibility of magnesium alloys for the next-generation vascular stents10.1039/c3nr02912c ↗
28. Biocorrosion properties of as-extruded Mg–Nd–Zn–Zr alloy compared with commercial AZ31 and WE43 alloys10.1016/j.matlet.2011.08.079 ↗
29. Influence of fluoride treatment on surface properties, biodegradation and cytocompatibility of Mg-Nd-Zn-Zr alloy10.1007/s10856-013-5106-z ↗
30. Poly lactic-co-glycolic acid (PLGA) as biodegradable controlled drug delivery carrier10.3390/polym3031377 ↗
31. Acceleration of re-endothelialization and inhibition of neointimal formation using hybrid biodegradable nanofibrous rosuvastatin-loaded stents10.1016/j.biomaterials.2014.02.017 ↗
32. Local drug delivery via a coronary stent with programmable release pharmacokinetics10.1161/01.CIR.0000050367.65079.71 ↗
33. In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents10.1016/j.biomaterials.2010.02.003 ↗
34. Role of stent design and coatings on restenosis and thrombosis10.1016/j.addr.2006.01.022 ↗
35. In vitro release of the mTOR inhibitor rapamycin from poly(ethylene glycol)-b-poly(ε-caprolactone) micelles10.1016/j.jconrel.2005.10.008 ↗
36. Study of drug-eluting coating on metal coronary stent10.1016/j.msec.2012.12.049 ↗
37. The influence of yttrium (Y) on the corrosion of Mg–Y binary alloys10.1016/j.corsci.2010.07.019 ↗
38. The release kinetics of drug eluting stents containing sirolimus as coated drug: role of release media10.1016/j.jchromb.2010.01.023 ↗
39. Brushite (CaHPO4·2H2O) to octacalcium phosphate (Ca8(HPO4)2(PO4)4·5H2O) transformation in DMEM solutions at 36.5°C10.1016/j.msec.2009.10.009 ↗
40. Controlled release of sirolimus from a multilayered PLGA stent matrix10.1016/j.biomaterials.2006.07.016 ↗
41. Degradation of rapamycin and its ring-opened isomer: role of base catalysis10.3998/ark.5550190.0008.c09 ↗
42. Manipulation of the C(22)-C(27) region of rapamycin: stability issues and biological implications10.1016/S0960-894X(98)00735-5 ↗
43. Characterization of the initial burst release of a model peptide from poly (D, L-lactide-co-glycolide) microspheres10.1016/S0168-3659(02)00137-2 ↗
44. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices10.1016/j.jconrel.2004.04.011 ↗
45. In vitro degradation of thin poly (DL-lactic-co-glycolic acid) films10.1002/(SICI)1097-4636(199908)46:2<236::AID-JBM13>3.0.CO;2-F ↗
46. Poly (glycolic acid-co-dl-lactic acid): diffusion or degradation controlled drug delivery?10.1016/0168-3659(92)90171-M ↗
47. More about the degradation of LA/GA-derived matrices in aqueous media10.1016/0168-3659(91)90027-B ↗
48. The influence of microstructure and monomer properties on the erosion mechanism of a class of polyanhydrides10.1002/pola.1993.080311004 ↗
49. Mechanisms of polymer degradation and erosion10.1016/0142-9612(96)85755-3 ↗
50. Synthesis, characterization, biodegradation, and drug delivery application of biodegradable lactic/glycolic acid polymers Part II: biodegradation10.1163/156856201744425 ↗
51. A comparison of the effect of pH on the biodegradation of two synthetic absorbable sutures10.1097/00000658-198201001-00009 ↗
52. Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation10.1088/1748-6041/6/2/025005 ↗
53. Base catalyzed degradations of rapamycin10.1016/S0040-4039(00)79204-5 ↗
54. Studies on the chemistry of rapamycin: novel transformations under lewis-acid catalysis10.1016/S0040-4039(00)77473-9 ↗
55. Drug-eluting stents in vascular intervention10.1016/S0140-6736(03)12275-1 ↗
56. Rapamycin inhibits vascular smooth muscle cell migration10.1172/JCI119038 ↗
57. Endothelial cell recovery between comparator polymer-based drug-eluting stents10.1016/j.jacc.2008.04.030 ↗
58. Rapamycin (sirolimus) inhibits heart cell growth in vitro10.1007/s002469900359 ↗