Understanding the effect of magnesium degradation on drug release and anti-proliferation on smooth muscle cells for magnesium-based drug eluting stents
Source abstract
Abstract
Abstract To understand the possible influence of substrate degradation on the drug-loading system of magnesium alloy-based drug-eluting stents, a rapamycin drug-loading poly(lactic-co-glycolic acid) coating was prepared on Mg-Nd-Zn-Zr stents for a systematic investigation in a phosphate buffer system. Mg degradation accelerated the drug release kinetics prominently, which was mainly attributed to H2 evolution in the diffusion-controlled phase while thereafter to PLGA erosion. Although physiochemical stability of the released rapamycin was partially deteriorated by magnesium degradation, the drug-loading system on magnesium substrates exhibited a more potent long-term inhibition on smooth muscle cell proliferation in vitro as compared to drug-loaded stainless steel.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Second-and third-generation drug-eluting coronary stents10.1007/s00059-011-3458-z ↗
2. Paclitaxel-eluting versus uncoated stents in primary percutaneous coronary intervention10.1056/NEJMoa062598 ↗
3. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery10.1056/NEJMoa035071 ↗
4. Novel approaches to reduce restenosis10.1196/annals.1302.032 ↗
5. Drug-eluting stents10.1146/annurev.med.55.091902.105243 ↗
6. The road to bioabsorbable stents: reaching clinical reality?10.1007/s00270-004-0341-9 ↗
7. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn10.1002/ccd.20756 ↗
8. Control of biodegradation of biocompatable magnesium alloys10.1016/j.corsci.2007.01.001 ↗
9. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective non-randomised multicentre trial10.1016/S0140-6736(07)60853-8 ↗
10. Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial10.1016/S0140-6736(12)61765-6 ↗
11. Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial10.1016/S0140-6736(15)00447-X ↗
12. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?10.1136/heart.89.6.651 ↗
13. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human Coronary arteries10.1016/j.jcin.2008.09.015 ↗
14. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries10.1002/ccd.20727 ↗
15. Bioresorbable drug-eluting magnesium-alloy scaffold: design and feasibility in a porcine coronary model10.4244/EIJV8I12A218 ↗
16. Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis10.1583/10-3353.1 ↗
17. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby10.1002/ccd.20520 ↗
18. safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial10.1093/eurheartj/ehw196 ↗
19. Mechanisms of controlled drug release from drug-eluting stents10.1016/j.addr.2006.01.016 ↗
20. Corrosion of magnesium alloy AZ31: The influence of bicarbonate, sulphate, hydrogen phosphate and dihydrogen phosphate ions in saline solution10.1016/j.corsci.2014.05.006 ↗
21. In vitro degradation behavior and biocompatibility of Mg–Nd–Zn–Zr alloy by hydrofluoric acid treatment10.1016/j.msec.2012.08.036 ↗
22. The development of binary Mg–Ca alloys for use as biodegradable materials within bone10.1016/j.biomaterials.2007.12.021 ↗
23. The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ9110.1016/j.corsci.2013.06.019 ↗
24. Biphasic responses of human vascular smooth muscle cells to magnesium ion10.1002/jbm.a.35570 ↗
25. Combined effect of composition and surface condition on corrosion behaviour of magnesium alloys AZ31 and AZ6110.1016/j.corsci.2012.10.034 ↗
26. Assessment of localized corrosion under simulated physiological conditions of magnesium samples with heterogeneous microstructure: value of X-ray computed micro-tomography platform10.1016/j.corsci.2015.12.009 ↗
27. Nanophasic biodegradation enhances the durability and biocompatibility of magnesium alloys for the next-generation vascular stents10.1039/c3nr02912c ↗
28. Biocorrosion properties of as-extruded Mg–Nd–Zn–Zr alloy compared with commercial AZ31 and WE43 alloys10.1016/j.matlet.2011.08.079 ↗
29. Influence of fluoride treatment on surface properties, biodegradation and cytocompatibility of Mg-Nd-Zn-Zr alloy10.1007/s10856-013-5106-z ↗
30. Poly lactic-co-glycolic acid (PLGA) as biodegradable controlled drug delivery carrier10.3390/polym3031377 ↗
31. Acceleration of re-endothelialization and inhibition of neointimal formation using hybrid biodegradable nanofibrous rosuvastatin-loaded stents10.1016/j.biomaterials.2014.02.017 ↗
32. Local drug delivery via a coronary stent with programmable release pharmacokinetics10.1161/01.CIR.0000050367.65079.71 ↗
33. In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents10.1016/j.biomaterials.2010.02.003 ↗
34. Role of stent design and coatings on restenosis and thrombosis10.1016/j.addr.2006.01.022 ↗
35. In vitro release of the mTOR inhibitor rapamycin from poly(ethylene glycol)-b-poly(ε-caprolactone) micelles10.1016/j.jconrel.2005.10.008 ↗
36. Study of drug-eluting coating on metal coronary stent10.1016/j.msec.2012.12.049 ↗
37. The influence of yttrium (Y) on the corrosion of Mg–Y binary alloys10.1016/j.corsci.2010.07.019 ↗
38. The release kinetics of drug eluting stents containing sirolimus as coated drug: role of release media10.1016/j.jchromb.2010.01.023 ↗
39. Brushite (CaHPO4·2H2O) to octacalcium phosphate (Ca8(HPO4)2(PO4)4·5H2O) transformation in DMEM solutions at 36.5°C10.1016/j.msec.2009.10.009 ↗
40. Controlled release of sirolimus from a multilayered PLGA stent matrix10.1016/j.biomaterials.2006.07.016 ↗
41. Degradation of rapamycin and its ring-opened isomer: role of base catalysis10.3998/ark.5550190.0008.c09 ↗
42. Manipulation of the C(22)-C(27) region of rapamycin: stability issues and biological implications10.1016/S0960-894X(98)00735-5 ↗
43. Characterization of the initial burst release of a model peptide from poly (D, L-lactide-co-glycolide) microspheres10.1016/S0168-3659(02)00137-2 ↗
44. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices10.1016/j.jconrel.2004.04.011 ↗
45. In vitro degradation of thin poly (DL-lactic-co-glycolic acid) films10.1002/(SICI)1097-4636(199908)46:2<236::AID-JBM13>3.0.CO;2-F ↗
46. Poly (glycolic acid-co-dl-lactic acid): diffusion or degradation controlled drug delivery?10.1016/0168-3659(92)90171-M ↗
47. More about the degradation of LA/GA-derived matrices in aqueous media10.1016/0168-3659(91)90027-B ↗
48. The influence of microstructure and monomer properties on the erosion mechanism of a class of polyanhydrides10.1002/pola.1993.080311004 ↗
49. Mechanisms of polymer degradation and erosion10.1016/0142-9612(96)85755-3 ↗
50. Synthesis, characterization, biodegradation, and drug delivery application of biodegradable lactic/glycolic acid polymers Part II: biodegradation10.1163/156856201744425 ↗
51. A comparison of the effect of pH on the biodegradation of two synthetic absorbable sutures10.1097/00000658-198201001-00009 ↗
52. Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation10.1088/1748-6041/6/2/025005 ↗
53. Base catalyzed degradations of rapamycin10.1016/S0040-4039(00)79204-5 ↗
54. Studies on the chemistry of rapamycin: novel transformations under lewis-acid catalysis10.1016/S0040-4039(00)77473-9 ↗
55. Drug-eluting stents in vascular intervention10.1016/S0140-6736(03)12275-1 ↗
56. Rapamycin inhibits vascular smooth muscle cell migration10.1172/JCI119038 ↗
57. Endothelial cell recovery between comparator polymer-based drug-eluting stents10.1016/j.jacc.2008.04.030 ↗
58. Rapamycin (sirolimus) inhibits heart cell growth in vitro10.1007/s002469900359 ↗