Detection of corrosion steel under an organic coating by infrared photography
Source abstract
Abstract
Abstract The application of an infrared camera for detecting corrosion under organic coatings was studied. The ruptured blistering area, blister and filiform corrosion can be monitored easily by infrared thermography. When the corroded specimen is heated, the temperature at the surface over the corroded area changed differently according to the type of corrosion. The extent of increase in temperature was in the following sequence: ruptured blister > filiform filament > intact part > blister. From the analysis of temperature distribution at the surface of specimen, the location, shape and size of the corroded area can be estimated.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Thermography and Photoacoustic Techniques · Advanced Measurement and Detection Methods · Conservation Techniques and Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (6)
Show source-provided references
1. Rajic · J. Nondestruct. Eval. · 2000 · 19 · 14110.1023/A:1010760130264 ↗
2. Vavilov · Int. J. Heat Transfer · 1996 · 39 · 35510.1016/0017-9310(95)00126-T ↗
3. Maierhofer · Infrared Phys. Technol. · 2002 · 43 · 27110.1016/S1350-4495(02)00151-2 ↗
4. Martin · J. Coat. Technol. · 1985 · 57 · 31
5. Chang · Corros. Sci. · 2003 · 45 · 268910.1016/S0010-938X(03)00082-9 ↗
6. McKnight · ASTM STP · 1984 · 841 · 13