An SMFL-based non-destructive quantification method for the localized corrosion cross-sectional area of rebar
Source abstract
Abstract
Abstract The non-destructive quantitative evaluation of the rebar corrosion degree is an urgent problem to be solved for corroded reinforced concrete structures. In this study, a non-destructive quantification method for the rebar localized corrosion cross-sectional area was proposed based on the dynamic linkage mechanism of the induced magnetic and self-magnetic flux leakage fields of rebar. As verified by data from the experiment and the finite element simulation, this quantification method could eliminate the adverse influence of the magnetic property differences of the rebar. The results indicated that different quantitative indices for corrosion evaluation could be created based on this method, and an index created by two transformations with the same geometric characteristics had better quantification capability. The four quantitative indices I1, I2, I3, and I4 created in this study were all linearly related to the rebar localized corrosion cross-sectional area ratio S, and index I3 had the relatively best quantitative capability and applicability. This quantification method provided an innovative solution for the non-destructive quantitative evaluation of rebar corrosion.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Rebar corrosion detection, protection, and rehabilitation of reinforced concrete structures in coastal environments: a review10.1016/j.conbuildmat.2019.07.250 ↗
2. Enhancing corrosion resistance of reinforced concrete structures with hybrid fiber reinforced concrete10.1016/j.corsci.2014.12.003 ↗
3. Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams10.1016/j.cemconres.2013.11.006 ↗
4. Prediction of corrosion-induced cover cracking in reinforced concrete structures10.1016/j.conbuildmat.2010.11.074 ↗
5. Modelling corrosion propagation in reinforced concrete structures–a critical review10.1016/j.cemconcomp.2010.11.002 ↗
6. Bond degradation of non-uniformly corroded steel rebars in concrete10.1016/j.engstruct.2020.111392 ↗
7. Characterization of steel reinforcement corrosion in concrete using 3D laser scanning techniques
8. Corrosion damage assessment of a reinforced concrete canal structure of power plant after 20 years of exposure in a marine environment: a case study10.1016/j.engfailanal.2017.11.014 ↗
9. Influence of chloride ions and hot weather on isolated rusting steel bar in concrete based on NDT and electro-chemical model evaluation10.1016/j.ndteint.2010.11.010 ↗
10. Corrosion monitoring of reinforced concrete structures-A10.1016/S1452-3981(23)17049-0 ↗
11. Non-destructive evaluation for corrosion monitoring in concrete: a review and capability of acoustic emission technique10.3390/s150819069 ↗
12. Accounting for variability and uncertainties in NDT condition assessment of corroded RC-structures10.1080/19648189.2009.9693135 ↗
13. Uncertainty assessment of concrete electrical resistivity measurements on a coastal bridge10.1080/15732479.2018.1557703 ↗
14. Application of artificial neural network (ANN) technique to reduce uncertainty on corrosion assessment of rebars in concrete by NDT method
15. Acoustic emission monitoring of corrosion damage propagation in large-scale reinforced concrete beams10.1061/(ASCE)CF.1943-5509.0001127 ↗
16. Corrosion detection in reinforced concrete using induction heating and infrared thermography10.1007/s13349-010-0002-4 ↗
17. In-situ monitoring of corrosion-induced expansion and mass loss of steel bar in steel fiber reinforced concrete using a distributed fiber optic sensor10.1016/j.compositesb.2019.02.051 ↗
18. Field test of magnetic methods for corrosion detection in prestressing strands in adjacent box-beam bridges10.1061/(ASCE)BE.1943-5592.0000379 ↗
19. Practical assessment of magnetic methods for corrosion detection in an adjacent precast, prestressed concrete box-beam bridge10.1080/10589759.2012.695785 ↗
20. Bridge deck assessment using infrastructure corrosion assessment magnetic method (iCAMM™) technology, a case study of a culvert in Markham city, Ontario, Canada10.1016/j.ndteint.2020.102356 ↗
21. Research on the method of predicting corrosion width of cables based on the spontaneous magnetic flux leakage10.3390/ma12132154 ↗
22. T.C. Jensen, S.E. Wendt, J.N. Gray, D.J. Eisenmann, F.J. Margetan, C.C.H. Lo, N. Nakagawa, L.H. Brasche, Feasibility Study for Detection and Quantification of Corrosion in Bridge Barrier Rails, Iowa, Dept. of Transportation. (2013).
23. Jensen · 2015
24. Evaluation of eddy current and magnetic techniques for inspecting rebars in bridge barrier rails10.1063/1.4789202 ↗
25. Experimental and numerical study of an electromagnetic sensor for non-destructive evaluation of steel corrosion in concrete
26. Magnetic flux leakage technique to detect loss in metallic area in external post-tensioning systems10.1016/j.engstruct.2019.109765 ↗
27. Cross-sectional loss quantification for main cable NDE based on the BH loop measurement using a total flux sensor
28. A new judging criterion for corrosion testing of reinforced concrete based on self-magnetic flux leakage
29. Inductive and magnetic field inspection systems for rebar visualization and corrosion estimation in reinforced and pre-stressed concrete10.1080/10589750701362616 ↗
30. Probability evaluation method of cable corrosion degree based on self-magnetic flux leakage10.1016/j.jmmm.2020.167544 ↗
31. Statistical quantitative evaluation of bending strength of corroded RC beams via SMFL technique10.1016/j.engstruct.2020.110168 ↗
32. Quantitative evaluation of corrosion degrees of steel bars based on self-magnetic flux leakage10.3390/met9090952 ↗
33. Magnetic charge model for 3D MMM signals10.1080/10589759.2015.1064121 ↗
34. Dipole modeling of magnetic flux leakage10.1109/TMAG.2008.2011895 ↗
35. Experimental analysis of the correlation between bending strength and SMFL of corroded RC beams10.1016/j.conbuildmat.2019.04.120 ↗
36. An innovative corrosion evaluation technique for reinforced concrete structures using magnetic sensors10.1016/j.conbuildmat.2016.12.157 ↗
37. Non-destructive testing of steel corrosion fluctuation parameters based on spontaneous magnetic flux leakage and its relationship with steel bar diameter10.3390/ma12244116 ↗