Correlation between corrosion rate and AE signal in an acidic environment for mild steel
Source abstract
Abstract
Abstract The AE method is an effective technique for inspecting corrosion damage of mild steel, such as tank bottom floors. However, the correlation between AE signals and corrosion behaviour for mild steel has not yet been fully clarified. In the present study, the authors considered that the corrosion regions of bottom floors become a strong acid environment by Cl − , as reported in a previous study. Thus, the polarization resistance for the test pieces of mild steel was measured with an AC impedance method under a strong acid environment. It was clear that the polarization resistance indicated the corrosion rate for a test piece of mild steel in the experiments. While measuring the AE signals, the corrosion rate was monitored with a test piece. As a result, the AE signal showed good correlation with the corrosion rates of the test pieces. The corrosion behaviour of the test pieces was then discussed with the corrosion potential measured during the experiments. Furthermore, the cathode current was changed to control the generated hydrogen gas volume. The volume of the hydrogen gas generated from the cathode reaction was correlated to the AE signals.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Evaluation of corrosion damage on bottom floor of oil storage tank by acoustic emission
2. Current status of AE tank floor testing
3. Verification of acoustic emission testing of floor conditions in aboveground tanks by comparison of acoustic emission data and floor scan testing
4. High pressure institute of Japan recommended practice for acoustic emission testing for corrosion in the bottom floor of aboveground tanks
5. AE analysis during corrosion, stress corrosion cracking and corrosion fatigue processes
6. Evaluation of stress corrosion crack initiation using acoustic emission10.5006/1.3585225 ↗
7. AE response of α-brass during stress corrosion crack propagation10.1016/j.corsci.2007.03.043 ↗
8. Evaluation of stress corrosion cracking phenomenon in an AISI type 316LN stainless steel using acoustic emission technique10.1016/j.corsci.2006.06.007 ↗
9. Acoustic emission study of active–passive transitions during carbon steel erosion–corrosion in concentrated sulfuric acid10.1016/S0010-938X(01)00148-2 ↗
10. Characterization and control of selective corrosion of α,β′-brass by acoustic emission10.1016/S0963-8695(02)00102-0 ↗
11. Ability of acoustic emission technique for detection and monitoring of crevice corrosion on 304L austenitic stainless steel10.1016/S0963-8695(03)00065-3 ↗
12. Initiation and propagation steps in pitting corrosion of austenitic stainless steels: monitoring by acoustic emission10.1016/S0010-938X(00)00099-8 ↗
13. An acoustic emission technique for monitoring pitting corrosion of austenitic stainless steels10.1016/0010-938X(95)00036-J ↗
14. Investigation of pitting corrosion of stainless steel by means of acoustic emission and potentiodynamic methods10.1016/S0010-938X(03)00021-0 ↗
15. On the opportunity to use non-intrusive acoustic emission recordings for monitoring uniform corrosion of carbon steel and austenitic stainless steel in acid and neutral solutions10.1784/insi.2005.47.8.465 ↗
16. The correlation of acoustic emission with rate of corrosion10.1016/0010-938X(93)90042-F ↗
17. Development of AE monitoring method for corrosion damage of the bottom floor in oil storage tank on the neutral sand under loading10.2320/matertrans.47.1240 ↗
18. AE source and relation between AE activity and rate of corrosion of oil tank bottom floor on acidic soils10.2320/matertrans.46.2490 ↗