Interactions between wear and corrosion on cast and sintered Ti-12Nb alloy in comparison with the commercial Ti-6Al-4V alloy
Source abstract
Abstract
This work investigates the corrosion and tribocorrosion behavior of alfa + beta Ti-12Nb alloy processed by castingand sintering, in 9 g/l NaCl solution at body temperature, and compares the results with the commercial Ti-6Al-4 V alloy. Different electrochemical techniques were used to access the corrosion behavior. Tribocorrosion behavior was studied at open circuit potential under continuous and intermittent sliding, and at anodic potentiostatic condition under continuous sliding. Results revealed that Ti-12Nb alloys presented similar tribo-corrosion behavior although the sintered one exhibited a better corrosion behavior. Nevertheless, Ti-6Al-4 Vpresented better overall degradation resistance than both Ti-12Nb alloys.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Ti based biomaterials, the ultimate choice for orthopaedic implants - A review10.1016/j.pmatsci.2008.06.004 ↗
2. Titanium-based biomaterials for preventing stress shielding between implant devices and bone10.1155/2011/836587 ↗
3. Biocompatibility of Ti-alloys for long-term implantation10.1016/j.jmbbm.2012.11.014 ↗
4. Effect of Nb addition on microstructure evolution and nanomechanical properties of a glass-forming Ti-Zr-Si alloy10.1016/j.intermet.2013.11.010 ↗
5. Characterization, corrosion behavior, cellular response and in vivo bone tissue compatibility of titanium-niobium alloy with low Young’s modulus10.1016/j.msec.2015.10.062 ↗
6. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
7. Metallurgical properties and biomimetic HA deposition performance of Ti-Nb PIM alloys10.1016/j.jallcom.2018.02.274 ↗
8. Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
9. Influence of fabrication process on electrochemical and surface properties of Ti-6Al-4V alloy for medical applications10.1016/j.electacta.2013.01.155 ↗
10. The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses10.1098/rsif.2008.0142 ↗
11. Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques10.1016/j.wear.2012.04.014 ↗
12. Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva10.1016/j.jmbbm.2013.01.019 ↗
13. Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy10.1016/0142-9612(92)90018-J ↗
14. Progress in mechanical properties of gradient structured metallic materials induced by surface mechanical attrition treatment10.2320/matertrans.MF201911 ↗
15. Degradation behavior of Ti-Nb alloys: corrosion behavior through 21 days of immersion and tribocorrosion behavior against alumina10.1016/j.corsci.2020.108488 ↗
16. Wear and corrosion behaviour of Ti-13Nb-13Zr and Ti-6Al-4V alloys in simulated physiological solution10.1016/j.corsci.2010.11.014 ↗
17. Corrosion-wear of β-Ti alloy alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid10.1016/j.actbio.2016.07.008 ↗
18. Predominant factor determining wear properties of β-type and (α+β)-type titanium alloys in metal-to-metal contact for biomedical applications10.1016/j.jmbbm.2014.10.005 ↗
19. Development of Ti–Nb and Ti–Nb–Fe beta alloys from TiH2 powders10.1080/00325899.2018.1563953 ↗
20. Tribocorrosion: material behaviour under combined conditions of corrosion and mechanical loading, in: Corros
21. Ponthiaux · 2013
22. Stachowiak · 2000
23. Dry sliding and tribocorrosion behaviour of hot pressed CoCrMo biomedical alloy as compared with the cast CoCrMo and Ti6Al4V alloys10.1016/j.matdes.2013.05.032 ↗
24. Phase transformation textures in hot-rolled binary Ti-Nb alloys10.1007/s11661-013-1634-x ↗
25. Orazem · 2008
26. Repassivation of titanium and surface oxide film regeneration in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
27. Corrosion and tribocorrosion behaviour of Ti6Al4V produced by selective laser melting and hot pressing in comparison with the commercial alloy10.1016/j.jmatprotec.2018.11.008 ↗
28. Effects of Zr content on microstructure and corrosion resistance of Ti-30Nb-Zr casting alloys for biomedical applications10.1016/j.electacta.2007.10.060 ↗
29. Corrosion and passivation of annealed Ti-20Zr-6.5Al-4V alloy10.1016/j.corsci.2015.08.038 ↗
30. Modeling tribocorrosion of passive metals – a review
31. Tribocorrosion of passive materials: a review on test procedures and standards
32. Tribocorrosion behaviour of AISI 304 stainless steel in 0.5 M NaCl solution10.1016/j.matchemphys.2011.03.063 ↗
33. Corrosion wear characteristics of TC4, 316 stainless steel, and Monel K500 in artificial seawater10.1039/C7RA03065G ↗
34. Influence of electrochemical potential on the tribocorrosion behaviour of high carbon CoCrMo biomedical alloy in simulated body fluids by electrochemical impedance spectroscopy10.1016/j.electacta.2010.04.093 ↗
35. Tribocorrosion of 316L stainless steel and TA6V4 alloy in H2SO4 media10.1016/j.corsci.2009.03.015 ↗
36. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
37. Corrosion and tribocorrosion behavior of Ti-40Nb and Ti-25Nb-5Fe alloys processed by powder metallurgy10.1007/s11661-020-05757-6 ↗