journal article·2012-04-01

Low-Load Vickers Microindentation Hardness Testing

George F. Vander Voort, Ryan Fowler

AM&P Technical Articles· Volume 170· Issue 4
Publisher page

Abstract

Abstract This article reviews the measurement physics of macro and micro Vickers indentation testing and the factors that determine measurement precision and repeatability. Study results show that when force loads of less than 100 gf are used, it is difficult for operators to precisely determine the position of the indenter tip, leading to various measurement errors. These errors explain the data anomalies reported in the literature for low-load Vickers hardness testing, which are often incorrectly attributed to material characteristics.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Integrated Circuits and Semiconductor Failure Analysis · Advanced Measurement and Metrology Techniques · Advanced machining processes and optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Struers Inc. , Wadsworth, Illinois

Struers Inc. , Westlake, Ohio

References

Reference metadata was not supplied for this record.