Low-Load Vickers Microindentation Hardness Testing
Source abstract
Abstract
Abstract This article reviews the measurement physics of macro and micro Vickers indentation testing and the factors that determine measurement precision and repeatability. Study results show that when force loads of less than 100 gf are used, it is difficult for operators to precisely determine the position of the indenter tip, leading to various measurement errors. These errors explain the data anomalies reported in the literature for low-load Vickers hardness testing, which are often incorrectly attributed to material characteristics.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Integrated Circuits and Semiconductor Failure Analysis · Advanced Measurement and Metrology Techniques · Advanced machining processes and optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Struers Inc. , Wadsworth, Illinois
Struers Inc. , Westlake, Ohio
References
Reference metadata was not supplied for this record.