A comparative study of the corrosion and ion release behaviour of chromium oxide coatings exposed to saline, Ringer’s and Hank’s physiological solutions
Source abstract
Abstract
Abstract Chromium oxide coatings deposited on stainless steel substrates by RF reactive magnetron sputtering were tested for their corrosion and ion release behaviour in three physiological solutions. The Raman investigations showed that the coatings were predominantly Cr2O3. The coatings tested in Ringer’s and Hank’s solutions possess lower defect densities, better corrosion resistance, and lower ion release when compared to those tested in saline solution. The overall minimal chromium ion release from these samples suggests that the coatings have the potential to be used as an implantable coating for orthopaedic implant applications where material degradation and ion release remains a major concern.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Corrosion and surface modification on biocompatible metals: a review10.1016/j.msec.2017.04.102 ↗
2. Biomedical materials and techniques to improve the tribological, mechanical and biomedical properties of orthopedic implants – A review article10.1016/j.jallcom.2017.04.231 ↗
3. CoCrMo metal-on-metal hip replacements10.1039/C2CP42968C ↗
4. Metal ion measurement as a diagnostic tool to identify problems with metal-on-Metal hip resurfacing10.2106/JBJS.H.00672 ↗
5. Elevated serum cobalt with metal-on-metal articulating surfaces10.1302/0301-620X.79B2.0790316 ↗
6. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear10.1302/0301-620X.93B2.25099 ↗
7. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators10.1016/j.jmbbm.2012.08.009 ↗
8. Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity10.1002/jor.20826 ↗
9. Pseudotumours associated with metal-on-metal hip resurfacings10.1302/0301-620X.90B7.20213 ↗
10. Wear of surface engineered metal-on-metal hip prostheses10.1023/B:JMSM.0000015482.24542.76 ↗
11. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads10.1243/09544110260138709 ↗
12. An overview on diamond-like carbon coatings in medical applications10.1016/j.surfcoat.2013.04.015 ↗
13. Surface engineering : a low wearing solution for metal-on-Metal hip surface replacements10.1002/jbm.b.31317 ↗
14. Wear of surface-engineered metal-onmetal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup Ian
15. Diamond like carbon coatings for potential application in biological implants: a review10.1016/j.triboint.2012.09.006 ↗
16. Chromium oxide coatings with the potential for eliminating the risk of chromium ion release in orthopaedic implants10.1098/rsos.170218 ↗
17. In v itro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements10.1243/095441103765212659 ↗
18. Corrosion, ion release and Mott–Schottky probe of chromium oxide coatings in saline solution with potential for orthopaedic implant applications10.1088/2053-1591/3/4/045401 ↗
19. Corrosion and tribological behaviors of chromium oxide coatings prepared by the glow-discharge plasma technique10.1016/j.surfcoat.2009.06.020 ↗
20. Effect of temperature on the corrosion resistance of stainless steels in polluted phosphoric acid10.1016/S1452-3981(23)06669-5 ↗
21. Effect of temperature variation on the corrosion behaviour and semiconducting properties of the passive film formed on chromium oxide coatings exposed to saline solution10.1016/j.corsci.2019.04.004 ↗
22. Influence of RF power on the stoichiometry, optical, and electrical properties of chromium oxide coatings prepared by reactive magnetron sputtering10.1088/2053-1591/ab0d74 ↗
23. Growth and characterization of chromium oxide coatings prepared by pulsed-direct current reactive unbalanced magnetron sputtering10.1016/j.apsusc.2008.08.057 ↗
24. Synthesis, characterization, and growth mechanism of α-Cr2O3 monodispersed particles10.1016/j.jpcs.2011.02.015 ↗
25. High-pressure study of Cr 2 O 3 obtained by high-temperature oxidation by X-ray diffraction and Raman spectroscopy
26. Morphological and structural characterization of CrO2/Cr2O3 films grown by Laser-CVD10.1016/j.apsusc.2005.01.061 ↗
27. Thin Film Growth Through Sputtering Technique and Its Applications
28. Validation of corrosion rates measured by the Tafel extrapolation method10.1016/j.corsci.2005.05.046 ↗
29. Comparison of metal release from various metallic biomaterials in vitro10.1016/j.biomaterials.2004.02.005 ↗
30. Chemical composition and Mott-Schottky analysis of passive film formed on G3 alloy in bicarbonate/carbonate buffer solution
31. The effect of pitting corrosion on the fatigue strength of 304 and 316 stainless steel alloys
32. Electrochemical corrosion characteristics of super duplex stainless steel S32750 in LT-MED environment10.1016/S1452-3981(23)05098-8 ↗
33. Semiconducting properties of thermally grown oxide films on AISI 304 stainless steel10.1016/S0010-938X(99)00082-7 ↗
34. The electronic structure of passive films formed on stainless steels10.1016/0010-938X(95)00084-W ↗
35. Semiconducting properties of oxide and passive films formed on AISI 304 stainless steel and Alloy 60010.1590/S0103-50532002000400005 ↗
36. Influence of the temperature of film formation on the electronic structure of oxide films formed on 304 stainless steel10.1016/S0013-4686(01)00658-2 ↗
37. Electrochemistry of semiconductors10.1016/0038-092X(64)90079-9 ↗
38. Metastable pitting and semiconductive properties of passive films10.1149/1.2069520 ↗
39. Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316L stainless steel in physiological solution10.1002/maco.201006052 ↗
40. JASCO Quantitative Determination of Chromium by Diphenylcarbazide Method Appl. Note UV-0004 1–4 https://jascoinc.com/wp-content/uploads/2017/09/APP-Note-UV0004-Chromium-Quantitative-Determination.pdf.
41. Vogel · 1978
42. Resting membrane potential of skeletal muscle calculated from plasma and muscle electrolyte and water contents10.1042/cs0920391 ↗
43. Electrochemical corrosion and metal ion release from Co-Cr-Mo prosthesis with titanium plasma spray coating10.1016/j.biomaterials.2005.01.004 ↗
44. Banaszek · 2019 · 1
45. Electrochemical behavior of CoCrMo implant in Ringer’s solution10.1002/sia.5281 ↗
46. Influence of surrounding cations on the surface degradation of magnesium alloy implants under a compressive pressure chengyun
47. Influence of the composition of the hank’s balanced salt solution on the corrosion behavior of AZ31 and AZ61 magnesium alloys10.3390/met7110465 ↗
48. In vivo corrosion of CoCrMo alloy and biological responses: a review10.1080/10667857.2017.1408929 ↗
49. The effect of growth conditions on the surface energy, optical properties and saline corrosion resistance of amorphous chromium oxide thin films prepared by reactive magnetron sputtering
50. Boron phosphide protective coatings for hazardous radioactive waste and geothermal power applications10.1016/S1452-3981(23)11048-0 ↗