Show source-provided references
2. Physico-mechanical properties and prosthodontic applications of Co–Cr dental alloys: A review of the literature
10.4047/jap.2014.6.2.138 ↗5. Louwerens, J.K., Hockers, N., Achten, G., Sierevelt, I.N., Nolte, P.A., and Van Hove, R.P. (2020). No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial. Knee Surg. Sports Traumatol. Arthrosc., 1–7.
10.1007/s00167-020-05997-4 ↗6. Modulating the cobalt dose range to manipulate multisystem cooperation in bone environment: A strategy to resolve the controversies about cobalt use for orthopedic applications
10.7150/thno.37931 ↗7. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions
10.1111/prd.12185 ↗12. Evaluation of the carcinogenic risks to humans associated with surgical implants and other foreign bodies—A report of an IARC monographs programme meeting
10.1016/S0959-8049(99)00312-3 ↗14. (2020, November 21). Overview on the Medical Devices Legislation in the EU. Available online: https://www.ema.europa.eu/en/human-regulatory/overview/medical-devices#medical-devices-legislation-section.
16. Long-term evaluation of metal ion release in orthodontic patients using fluoridated oral hygiene agents: An in vivo study
18. Electrochemical behaviour of a cobalt–chromium–molybdenum dental alloy in artificial salivas
10.3233/BME-141241 ↗19. The biological response to orthopaedic implants for joint replacement: Part I: Metals
10.1002/jbm.b.33734 ↗20. Streptococcus mutans, caries and simulation models
24. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments
25. (2020, September 27). IARC Monographs on the Evaluation of Carcinogenic Risks to Humans. Chromium, Nickel and Welding. Available online: https://publications.iarc.fr/67.
27. CoCr wear particles generated from CoCr alloy metal-on-metal hip replacements, and cobalt ions stimulate apoptosis and expression of general toxicology-related genes in monocyte-like U937 cells
10.1016/j.taap.2014.09.010 ↗28. Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part II: Importance of physicochemical properties and dose in animal and in vitro studies as a basis for risk assessment
10.1016/j.nano.2015.02.006 ↗29. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: A state-of-the-art review
10.1080/10408444.2018.1563048 ↗30. Effect of Ni, W and Mo on the microstructure, phases and high-temperature sliding wear performance of CoCr matrix alloys
10.1080/14686996.2020.1752113 ↗31. Wear of dental materials: Clinical significance and laboratory wear simulation methods -A review
10.4012/dmj.2018-140 ↗32. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions
10.1002/jbm.b.33902 ↗33. The chemical form of metal species released from corroded taper junctions of hip implants: Synchrotron analysis of patient tissue
10.1038/s41598-017-11225-w ↗37. Ion release from three different dental alloys—Effect of dynamic loading and toxicity of released elements
38. Özçiçek Evaluation of corrosion resistance of Co–Cr alloys fabricated with different metal laser sintering systems
10.4047/jap.2020.12.3.114 ↗39. Corrosion assessment of an implantable dental Co–Cr alloy in artificial saliva and biocompatibility behavior
10.1007/s11665-020-04711-2 ↗40. Cobalt–chromium alloys fabricated with four different techniques: Ion release, toxicity of released elements and surface roughness
10.1016/j.dental.2020.08.012 ↗49. Vaicelyte, A., Janssen, C., Le Borgne, M., and Grosgogeat, B. (2020). Toxicological risks of the cobalt—Chromium alloys used in dentistry: A systematic review. J. Dent., in preparation.
51. Han, X., Sawada, T., Schille, C., Schweizer, E., Scheideler, L., Geis-Gerstorfer, J., Rupp, F., and Spintzyk, S. (2018). Comparative analysis of mechanical properties and metal-ceramic bond strength of Co–Cr dental alloy fabricated by different manufacturing processes. Materials, 11.
10.3390/ma11101801 ↗55. A cobalt spot test was useful in the diagnostic work-up of a cobalt allergic patient suffering from oral hypersensitivity to cobalt
10.1016/j.jaad.2010.05.015 ↗57. Comparing the effects of titanium alloy and chrome cobalt in removable partial denture connectors on tooth mobility, bone loss and tissue reaction
10.1016/j.sjdr.2016.01.001 ↗58. Metals are important contact sensitizers: An experience from Lithuania
59. Cobalt release and complications resulting from the use of dental prostheses
10.1111/cod.12649 ↗61. Drynda, A., Drynda, S., Kekow, J., Lohmann, C.H., and Bertrand, J. (2018). Differential effect of cobalt and chromium ions as well as CoCr particles on the expression of osteogenic markers and osteoblast function. Int. J. Mol. Sci., 19.
10.3390/ijms19103034 ↗62. (2020, August 16). IARC Monographs. Available online: https://monographs.iarc.fr/cards_page/publications-monographs/.
63. (2020, August 16). National Toxicology Program, Available online: https://ntp.niehs.nih.gov/pubhealth/roc/index-1.html.
65. Toxicology-based cancer causation analysis of CoCr-containing hip implants: A quantitative assessment of genotoxicity and tumorigenicity studies
10.1002/jat.3039 ↗66. (2020, August 28). Biological Responses to Metal Implants, Available online: https://www.fda.gov/media/132446/download.
69. The cytotoxicity of dental alloys studied on cell culture
70. The study of cytocompatibility of Co–Cr alloy and Ti alloy
71. Metallic ion content and damage to the DNA in oral mucosa cells of children with fixed orthodontic appliances
10.1007/s10534-011-9448-z ↗72. Biomonitoring of humans exposed to arsenic, chromium, nickel, vanadium, and complex mixtures of metals by using the micronucleus test in lymphocytes
10.1016/j.mrrev.2016.03.003 ↗73. (2020, August 28). RAC Opinion on Cobalt. Available online: https://echa.europa.eu/documents/10162/b7316b11-ae65-1dd0-2e64-bb6ad3efbd82.
74. (2020, November 11). Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices. Available online: http://data.europa.eu/eli/reg/2017/745/oj.
76. (2020, November 11). Council Directive 93/42/EEC of 14 June 1993 Concerning Medical Devices. Available online: http://data.europa.eu/eli/dir/1993/42/oj.
77. (2020, November 11). Regulation (EU) 2020/561 of the European Parliament and of the Council of 23 April 2020. Available online: http://data.europa.eu/eli/reg/2020/561/oj.
78. (2020, November 11). Commission Implementing Regulation (EU) 2017/2185 of 23 November 2017. Available online: http://data.europa.eu/eli/reg_impl/2017/2185/oj.
79. (2020, November 11). Regulation (EC) No 1907/2006 of 18 December 2006 Concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH). Available online: http://data.europa.eu/eli/reg/2006/1907/2014-04-10.
80. (2020, November 15). Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on Classification, Labelling and Packaging of Substances and Mixtures. Available online: http://data.europa.eu/eli/reg/2008/1272/oj.
81. (2020, November 15). Registered Substances ECHA. Available online: https://echa.europa.eu/information-on-chemicals/registered-substances.
82. (2020, November 15). Table of Harmonised Entries in annex VI to CLP. Available online: https://echa.europa.eu/documents/10162/13626/annex_vi_clp_table_atp14_en.xlsx/c767afd2-4d53-b8d5-de2b-0820680cac95.
83. Quantitative in vivo biocompatibility of new ultralow-nickel cobalt-chromium-molybdenum alloys
10.1002/jor.23150 ↗84. Mertová, K., Palán, J., Németh, G., Fintová, S., Duchek, M., Studecký, T., Veselý, J., Máthis, K., Džugan, J., and Trojanová, Z. (2020). Optimization of the mechanical performance of titanium for biomedical applications by advanced, high-gain SPD technology. Crystals, 10.
10.3390/cryst10060422 ↗