During the 20th century, metal alloys have assumed an important role as restorative materials. Among existing examples, cobalt–chromium (Co–Cr) alloys increasingly began to be used in medicine and especially in dentistry. Their success is mainly due to their mechanical properties such as stiffness, strength and corrosion resistance, thus allowing a high biocompatibility. There are quite meaningful data on the corrosion and toxicity of Co–Cr alloys for their use in restorative materials such as dental prostheses. Toxicological studies following Co and Cr exposures in the oral cavity are more difficult to conduct because there are many different situations leading to the release of metal ions and wear particles. Furthermore, the links between exposure and the appearance of local or systemic toxicity are not automatic. Since 2017, the European Union (EU) regulatory framework for Co–Cr alloys has been undergoing profound changes. A new EU Medical Devices Regulation (MDR) (2017/745) will be applied in May 2021 with the need to consider that Co metal is a new carcinogenic, mutagenic and toxic to reproduction (CMR) substance. On 18 February 2020, the 14th Adaptation to Technical Progress (ATP14) to the Classification, Labelling and Packaging (CLP) regulation was published, including the harmonised classification for Co metal as a CMR 1B substance. In this context, the use of Co might be forbidden if the medical devices are invasive and as soon as they include more than 0.1% (m/m) Co. This review provides a specific overview on Co–Cr dental alloys in terms of metal ions and wear particles release, toxicological risks, and the actual and new EU regulatory framework.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Dental materials and restorations · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratoire des Multimatériaux et Interfaces, CNRS UMR 5615, Universite Claude Bernard Lyon 1, Universite de Lyon, F-69622 Villeurbanne, France

Institut de Formation en Masso-Kinesitherapie pour Deficients de la Vue (IFMK DV), F-69373 Lyon, France

EA 4446 Bioactive Molecules and Medicinal Chemistry, Faculte de Pharmacie-ISPB, SFR Sante Lyon-Est CNRS UMS3453-INSERM US7, Universite Claude Bernard Lyon 1, Universite de Lyon, F-69373 Lyon, France

Small Molecules for Biological Targets Team, Centre de Recherche en Cancerologie de Lyon, Centre Leon Berard, CNRS 5286, INSERM 1052, Universite Claude Bernard Lyon 1, Univ Lyon, 69373 Lyon, France

Hospices Civils de Lyon, Service d’Odontologie, F-69007 Lyon, France

Faculte d’Odontologie, Universite Claude Bernard Lyon 1, Universite de Lyon, F-69008 Lyon, France

References (84)

Show source-provided references
1. Cobalt-base alloys used in bone surgery10.1016/S0020-1383(00)80018-2 ↗
2. Physico-mechanical properties and prosthodontic applications of Co–Cr dental alloys: A review of the literature10.4047/jap.2014.6.2.138 ↗
3. Orsiro cobalt-chromium sirolimus-eluting stent: Present and future perspectives10.1080/17434440.2017.1378091 ↗
4. The Ultimaster coronary stent system: 5-year worldwide experience10.2217/fca-2019-0093 ↗
5. Louwerens, J.K., Hockers, N., Achten, G., Sierevelt, I.N., Nolte, P.A., and Van Hove, R.P. (2020). No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial. Knee Surg. Sports Traumatol. Arthrosc., 1–7.10.1007/s00167-020-05997-4 ↗
6. Modulating the cobalt dose range to manipulate multisystem cooperation in bone environment: A strategy to resolve the controversies about cobalt use for orthopedic applications10.7150/thno.37931 ↗
7. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions10.1111/prd.12185 ↗
8. Surface structures of the two allotropic phases of cobalt10.1103/PhysRevB.17.1510 ↗
9. Effect of cobalt precursors on cobalt-hydroxyapatite used in bone regeneration and MRI10.1177/0022034519897006 ↗
10. Molecular analysis of chromium and cobalt-related toxicity10.1038/srep05729 ↗
11. Chromium as an essential nutrient for humans10.1006/rtph.1997.1136 ↗
12. Evaluation of the carcinogenic risks to humans associated with surgical implants and other foreign bodies—A report of an IARC monographs programme meeting10.1016/S0959-8049(99)00312-3 ↗
13. Release of chromium from orthopaedic arthroplasties10.2174/1874325000802010010 ↗
14. (2020, November 21). Overview on the Medical Devices Legislation in the EU. Available online: https://www.ema.europa.eu/en/human-regulatory/overview/medical-devices#medical-devices-legislation-section.
15. Wear characteristics of metallic biomaterials: A review10.3390/ma8052749 ↗
16. Long-term evaluation of metal ion release in orthodontic patients using fluoridated oral hygiene agents: An in vivo study
17. Release of metal ions from orthodontic appliances: An in vitro study10.1007/s12011-011-9233-4 ↗
18. Electrochemical behaviour of a cobalt–chromium–molybdenum dental alloy in artificial salivas10.3233/BME-141241 ↗
19. The biological response to orthopaedic implants for joint replacement: Part I: Metals10.1002/jbm.b.33734 ↗
20. Streptococcus mutans, caries and simulation models
21. Corrosion of alloys used in dentistry: A review10.1016/j.msea.2006.05.003 ↗
22. Corrosion by galvanic coupling between amalgam and different chromium-based alloys10.1016/j.dental.2006.11.006 ↗
23. In vivo corrosion of CoCrMo alloy and biological responses: A review10.1080/10667857.2017.1408929 ↗
24. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments
25. (2020, September 27). IARC Monographs on the Evaluation of Carcinogenic Risks to Humans. Chromium, Nickel and Welding. Available online: https://publications.iarc.fr/67.
26. High nitrogen steels. Nickel free high nitrogen austenitic steels10.2355/isijinternational.36.901 ↗
27. CoCr wear particles generated from CoCr alloy metal-on-metal hip replacements, and cobalt ions stimulate apoptosis and expression of general toxicology-related genes in monocyte-like U937 cells10.1016/j.taap.2014.09.010 ↗
28. Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part II: Importance of physicochemical properties and dose in animal and in vitro studies as a basis for risk assessment10.1016/j.nano.2015.02.006 ↗
29. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: A state-of-the-art review10.1080/10408444.2018.1563048 ↗
30. Effect of Ni, W and Mo on the microstructure, phases and high-temperature sliding wear performance of CoCr matrix alloys10.1080/14686996.2020.1752113 ↗
31. Wear of dental materials: Clinical significance and laboratory wear simulation methods -A review10.4012/dmj.2018-140 ↗
32. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions10.1002/jbm.b.33902 ↗
33. The chemical form of metal species released from corroded taper junctions of hip implants: Synchrotron analysis of patient tissue10.1038/s41598-017-11225-w ↗
34. Tooth wear and facial morphology10.1016/0300-5712(92)90019-9 ↗
35. Evaluation of metal ion release and corrosion resistance of ZrO2 thin coatings on the dental Co–Cr alloys10.1016/S0109-5641(99)00002-0 ↗
36. Cobalt-chromium alloys in dentistry: An evaluation of metal ion release10.1016/j.prosdent.2015.03.002 ↗
37. Ion release from three different dental alloys—Effect of dynamic loading and toxicity of released elements
38. Özçiçek Evaluation of corrosion resistance of Co–Cr alloys fabricated with different metal laser sintering systems10.4047/jap.2020.12.3.114 ↗
39. Corrosion assessment of an implantable dental Co–Cr alloy in artificial saliva and biocompatibility behavior10.1007/s11665-020-04711-2 ↗
40. Cobalt–chromium alloys fabricated with four different techniques: Ion release, toxicity of released elements and surface roughness10.1016/j.dental.2020.08.012 ↗
41. Patch Testing with dental screening series in oral disease10.5021/ad.2015.27.4.389 ↗
42. Cobalt, nickel and chromium release from dental tools and alloys10.1111/cod.12111 ↗
43. Snapshot of cobalt, chromium and nickel exposure in dental technicians10.1111/cod.12681 ↗
44. Friction-wear properties of nickel-free Co–Cr–Mo alloy in a simulated body fluid10.2320/matertrans.46.1588 ↗
45. Wear of human teeth: A tribological perspective10.1243/135065005X9655 ↗
46. Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions10.1016/j.wear.2010.12.045 ↗
47. Understanding the reactivity of CoCrMo-implant wear particles10.1038/s41529-018-0029-2 ↗
48. Development of a method in situ to study toothpaste abrasion of dentine10.1034/j.1600-051X.2002.291004.x ↗
49. Vaicelyte, A., Janssen, C., Le Borgne, M., and Grosgogeat, B. (2020). Toxicological risks of the cobalt—Chromium alloys used in dentistry: A systematic review. J. Dent., in preparation.
50. A review on role of essential trace elements in health and disease10.4103/2277-8632.158577 ↗
51. Han, X., Sawada, T., Schille, C., Schweizer, E., Scheideler, L., Geis-Gerstorfer, J., Rupp, F., and Spintzyk, S. (2018). Comparative analysis of mechanical properties and metal-ceramic bond strength of Co–Cr dental alloy fabricated by different manufacturing processes. Materials, 11.10.3390/ma11101801 ↗
52. Cobalt-chromium alloys in fixed prosthodontics in Sweden10.1080/23337931.2017.1360776 ↗
53. Cobalt-containing alloys and their ability to release cobalt and cause dermatitis10.1111/j.1600-0536.2008.01497.x ↗
54. Evaluation of tissue reaction to some denture-base materials: An animal study10.5005/jcdp-9-4-67 ↗
55. A cobalt spot test was useful in the diagnostic work-up of a cobalt allergic patient suffering from oral hypersensitivity to cobalt10.1016/j.jaad.2010.05.015 ↗
56. Allergic palmoplantar pustulosis caused by cobalt in cast dental crowns: A case report10.1016/j.tripleo.2010.12.013 ↗
57. Comparing the effects of titanium alloy and chrome cobalt in removable partial denture connectors on tooth mobility, bone loss and tissue reaction10.1016/j.sjdr.2016.01.001 ↗
58. Metals are important contact sensitizers: An experience from Lithuania
59. Cobalt release and complications resulting from the use of dental prostheses10.1111/cod.12649 ↗
60. Contact allergies to dental materials10.61872/sdj-2019-07-08-555 ↗
61. Drynda, A., Drynda, S., Kekow, J., Lohmann, C.H., and Bertrand, J. (2018). Differential effect of cobalt and chromium ions as well as CoCr particles on the expression of osteogenic markers and osteoblast function. Int. J. Mol. Sci., 19.10.3390/ijms19103034 ↗
62. (2020, August 16). IARC Monographs. Available online: https://monographs.iarc.fr/cards_page/publications-monographs/.
63. (2020, August 16). National Toxicology Program, Available online: https://ntp.niehs.nih.gov/pubhealth/roc/index-1.html.
64. Hexavalent chromium and stomach cancer: A systematic review and meta-analysis10.1080/10408444.2019.1578730 ↗
65. Toxicology-based cancer causation analysis of CoCr-containing hip implants: A quantitative assessment of genotoxicity and tumorigenicity studies10.1002/jat.3039 ↗
66. (2020, August 28). Biological Responses to Metal Implants, Available online: https://www.fda.gov/media/132446/download.
67. Carcinogenicity and mutagenicity of chromium10.1016/0165-1110(80)90018-4 ↗
68. Mutagenicity, carcinogenicity and teratogenicity of cobalt metal and cobalt compounds10.1016/0165-1110(90)90029-B ↗
69. The cytotoxicity of dental alloys studied on cell culture
70. The study of cytocompatibility of Co–Cr alloy and Ti alloy
71. Metallic ion content and damage to the DNA in oral mucosa cells of children with fixed orthodontic appliances10.1007/s10534-011-9448-z ↗
72. Biomonitoring of humans exposed to arsenic, chromium, nickel, vanadium, and complex mixtures of metals by using the micronucleus test in lymphocytes10.1016/j.mrrev.2016.03.003 ↗
73. (2020, August 28). RAC Opinion on Cobalt. Available online: https://echa.europa.eu/documents/10162/b7316b11-ae65-1dd0-2e64-bb6ad3efbd82.
74. (2020, November 11). Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices. Available online: http://data.europa.eu/eli/reg/2017/745/oj.
75. Preventable exposures associated with human cancers10.1093/jnci/djr483 ↗
76. (2020, November 11). Council Directive 93/42/EEC of 14 June 1993 Concerning Medical Devices. Available online: http://data.europa.eu/eli/dir/1993/42/oj.
77. (2020, November 11). Regulation (EU) 2020/561 of the European Parliament and of the Council of 23 April 2020. Available online: http://data.europa.eu/eli/reg/2020/561/oj.
78. (2020, November 11). Commission Implementing Regulation (EU) 2017/2185 of 23 November 2017. Available online: http://data.europa.eu/eli/reg_impl/2017/2185/oj.
79. (2020, November 11). Regulation (EC) No 1907/2006 of 18 December 2006 Concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH). Available online: http://data.europa.eu/eli/reg/2006/1907/2014-04-10.
80. (2020, November 15). Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on Classification, Labelling and Packaging of Substances and Mixtures. Available online: http://data.europa.eu/eli/reg/2008/1272/oj.
81. (2020, November 15). Registered Substances ECHA. Available online: https://echa.europa.eu/information-on-chemicals/registered-substances.
82. (2020, November 15). Table of Harmonised Entries in annex VI to CLP. Available online: https://echa.europa.eu/documents/10162/13626/annex_vi_clp_table_atp14_en.xlsx/c767afd2-4d53-b8d5-de2b-0820680cac95.
83. Quantitative in vivo biocompatibility of new ultralow-nickel cobalt-chromium-molybdenum alloys10.1002/jor.23150 ↗
84. Mertová, K., Palán, J., Németh, G., Fintová, S., Duchek, M., Studecký, T., Veselý, J., Máthis, K., Džugan, J., and Trojanová, Z. (2020). Optimization of the mechanical performance of titanium for biomedical applications by advanced, high-gain SPD technology. Crystals, 10.10.3390/cryst10060422 ↗