The Influence of Design on Stress Concentration Reduction in Dental Implant Systems Using the Finite Element Method
Source abstract
Abstract
Dental implant fracture is closely connected to the stress buildup surrounding the implant system during static loading. In areas where the cross-section of the implant rapidly changes or where the geometry of the implant system has discontinuities, stress concentrations arise. Therefore, the implant’s design is crucial in preventing early failure of the implant system, including fracture, screw loosening, and increased leakage, in addition to reducing stresses at the implant–abutment interface. In the current work, three-dimensional (3D) models of mechanically connected Ti6-Al-4V implant systems in various dimensions were constructed. Finite element analysis (FEA) was used to conduct a stress study of the created implants under actual acting force static loading conditions in accordance with ISO 14801. In the created models, design elements including implant screw type, thickness, and taper angle of abutment were modified in order to increase the longevity of the implants. The results show that the equivalent stress level was dramatically reduced from 596.22 MPa to 212.72 MPa in the implant model, which exhibits a more homogeneous stress pattern under static loading conditions. By increasing the implant wall thickness from 0.15 mm to 0.40 mm in the region adjacent to the abutment, the stress levels, especially at the internal screw, were significantly reduced. Also, the design modification in Model B, establishing contact between the abutment and the upper part of the conical surface of the implant, resulted in a decrease in stress in the internal screw. Thus, enhanced homogeneity in stress distribution not only improves the harmony between the implant and surrounding tissues, thus increasing patient comfort and reducing the risk of complications, but also holds promise for the development of new implants capable of withstanding the forces encountered in the oral environment due to the relatively smoother stress transmission observed in this model.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
MarlaDT Engineering, Adalet Mahallesi. Folkart Towers A Kule No:47/B, Bayrakli, Izmir 35530, Turkey
Materials and Surface Engineering Group, Chemnitz University of Technology, Erfenschlager Str. 73, 09125 Chemnitz, Germany
Funding
Alexander von Humboldt Foundation 10. Round PSI
References (26)
Show source-provided references
1. Stress analysis and factor of safety in three dental implant systems by finite element analysis10.1016/j.sdentj.2022.08.006 ↗
2. Finite Element Analysis of an Osseointegrated Stepped Screw Dental Implant10.1563/0654.1 ↗
3. Review on finite element analysis of dental implants10.54527/jdir.2022.41.3.50 ↗
4. A digital image correlation analysis on the influence of crown material in implant-supported prostheses on bone strain distribution10.1016/j.jpor.2011.05.003 ↗
5. Three-dimensional finite element stress analysis of uneven-threaded ti dental implant
6. Finite Element Analysis of Dental Implants with and without Microthreads under Static and Dynamic Loading
7. Finite element analysis of the biomechanical effects of titanium and Cfr-peek additively manufactured subperiosteal jaw implant (AMSJI) on maxilla10.1016/j.jormas.2022.09.011 ↗
8. Static, dynamic and fatigue behaviors of dental implant using finite element method10.1016/j.advengsoft.2006.02.004 ↗
9. Farronato, D., Manfredini, M., Stevanello, A., Campana, V., Azzi, L., and Farronato, M. (2019). A Comparative 3D Finite Element Computational Study of Three Connections. Materials, 12.10.3390/ma12193135 ↗
10. Effect Of Dental Implant Dimensions On Fatigue Behaviour: A Numerical Approach
11. Finite Element Analysis of a New Dental Implant Design Optimized for the Desirable Stress Distribution in the Surrounding Bone Region10.3390/prosthesis2030019 ↗
12. Numerical study of the effect of dental implant inclination10.24874/jsscm.2017.11.02.06 ↗
13. Finite Element Analysis of Stress in Bone and Abutment-Implant Interface under Static and Cyclic Loadings
14. Comparative evaluation of three abutment–implant interfaces on stress distribution in and around different implant systems: A finite element analysis10.4103/ccd.ccd_739_18 ↗
15. Wang, P.-S., Tsai, M.-H., Wu, Y.-L., Chen, H.-S., Lei, Y.-N., and Wu, A.Y.-J. (2023). Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant–Abutment Connections: A Three-Dimensional Finite Element Study. J. Funct. Biomater., 14.10.3390/jfb14100515 ↗
16. Finite Element Analysis of the Effect of Dental Implants on Jaw Bone under Mechanical and Thermal Loading Conditions10.1155/2021/9281961 ↗
17. Tonin, B.S., Fu, J., He, Y., Ye, N., Chew, H.P., and Fok, A. (2023). The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study. J. Mech. Behav. Biomed. Mater., 142.10.1016/j.jmbbm.2023.105847 ↗
18. Sun, F., Lv, L.-T., Cheng, W., Zhang, J.-L., Ba, D.-C., Song, G.-Q., and Lin, Z. (2021). Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. Materials, 14.10.3390/ma14195542 ↗
19. Fatigue behavior and osseointegration of porous Ti-6Al-4V scaffolds with dense core for dental application10.1016/j.matdes.2020.108994 ↗
20. Finite element analysis of stress concentration between surface coated implants and non surface coated implants-An in vitro study10.4317/jced.55915 ↗
21. (2023, October 09). Available online: https://asm.matweb.com/search/SpecificMaterial.asp?bassnum=mtp641.
22. Desai, S.R., Koulgikar, K.D., Alqhtani, N.R., Alqahtani, A.R., Alqahtani, A.S., Alenazi, A., Heboyan, A., Fernandes, G.V.O., and Mustafa, M. (2023). Three-Dimensional FEA Analysis of the Stress Distribution on Titanium and Graphene Frameworks Supported by 3 or 6-Implant Models. Biomimetics, 8.10.3390/biomimetics8010015 ↗
23. (2016). Dentistry—Implants—Dynamic Loading Test for Endosseous Dental Implants (Standard No. ISO 14801:2016).
24. (2022). ANSYS Meshing User’s Guide, ANSYS, Inc.
25. The effects of design parameters on mechanical failure of Ti-6Al-4V implants using finite element analysis10.1016/j.engfailanal.2020.104445 ↗
26. Jeng, M.-D., Lin, Y.-S., and Lin, C.-L. (2020). Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis. Appl. Sci., 10.10.3390/app10103471 ↗