journal article·2020-09-18Open access

Dual-Energy X-ray Medical Imaging with Inverse Compton Sources: A Simulation Study

Gianfranco Paternò, Paolo Cardarelli, Mauro Gambaccini, Angelo Taibi

Crystals· Volume 10· Issue 9

Abstract

It has been long recognized that dual-energy imaging could help to enhance the detectability of lesions in diagnostic radiology, by removing the contrast of surrounding tissues. Furthermore, X-ray attenuation is material specific and information about the object constituents can be extracted for tissue characterisation, i.e., to assess whether lesions represent a malignant or benign process. However, a true separation between the low and high energy components is not possible with conventional sources because of their broad X-ray spectrum, and the artifacts produced in the subtracted image can be only partially removed. Finally, dose issues have also prevented so far the application of dual-energy techniques within the clinical context. Very recently, a new intense and monochromatic X-ray source was proposed to fill the gap between a synchrotron radiation facility and the standard X-ray tube. Indeed, inverse Compton scattering (ICS) sources, which are based on the interaction of a powerful laser beam and a bright beam of relativistic electrons, are among the most promising innovative sources of monochromatic X and gamma radiation. In this contribution, we review the main features that allow an ICS source to meet the requirements of a medical imaging application. Specific examples of K-edge subtraction are then provided, to show the potential of ICS in clinical applications that require intravenous injection of a contrast medium.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Radiation Dose and Imaging · Advanced X-ray Imaging Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dip. Fisica e Scienze della Terra, Università di Ferrara, via Saragat 1, I-44122 Ferrara, Italy

INFN–Sez. di Ferrara, Università di Ferrara, via Saragat 1, I-44122 Ferrara, Italy

References (64)

Show source-provided references
1. Energy-selective reconstructions in X-ray computerised tomography10.1088/0031-9155/21/5/002 ↗
2. Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications10.1148/radiol.2015142631 ↗
3. An update on dual-energy X-ray absorptiometry10.1053/j.semnuclmed.2009.08.001 ↗
4. Dual energy subtraction: Principles and clinical applications10.1016/j.ejrad.2009.03.046 ↗
5. Dichromatic absorption radiography. Dichromography
6. K-edge subtraction synchrotron X-ray imaging in bio-medical research10.1016/j.ejmp.2018.04.389 ↗
7. Absorption edge fluoroscopy using quasi-monoenergetic X-ray beams
8. Selective iodine imaging using lanthanum K fluorescence10.1118/1.595447 ↗
9. K-edge digital subtraction imaging based on a dichromatic and compact X-ray source10.1088/0031-9155/49/14/019 ↗
10. Photon-counting CT: Technical principles and clinical prospects10.1148/radiol.2018172656 ↗
11. Riederer, I., Si-Mohamed, S., Ehn, S., Bar-Ness, D., Noël, P.B., Fingerle, A.A., Pfeiffer, F., Rummeny, E.J., Douek, P., and Pfeiffer, D. (2019). Differentiation between blood and iodine in a bovine brain—Initial experience with Spectral Photon-Counting Computed Tomography (SPCCT). PLoS ONE, 14.10.1371/journal.pone.0212679 ↗
12. Development of contrast digital mammography10.1118/1.1510128 ↗
13. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Polychromaticity correction10.1118/1.4933199 ↗
14. Risks and complications of coronary angiography: A comprehensive review
15. Generalized image combinations in dual KVP digital radiography10.1118/1.595025 ↗
16. K-edge digital subtraction imaging with dichromatic X-ray sources: SNR and dose studies10.1088/0031-9155/51/17/012 ↗
17. Nonlinear Thomson scattering of intense laser pulses from beams and plasmas10.1103/PhysRevE.48.3003 ↗
18. Three-dimensional time and frequency-domain theory of femtosecond X-ray pulse generation through Thomson scattering10.1103/PhysRevSTAB.7.060703 ↗
19. Theoretical and simulation studies of characteristics of a Compton light source10.1103/PhysRevSTAB.14.044701 ↗
20. Photon flux and spectrum of γ-rays Compton sources10.1016/j.nima.2012.07.015 ↗
21. Laser pulsing in linear Compton scattering10.1103/PhysRevAccelBeams.19.121302 ↗
22. A collimation system for ELI-NP Gamma Beam System–design and simulation of performance10.1016/j.nimb.2017.03.057 ↗
23. Krafft, G.A., and Priebe, G. (2010). Compton sources of electromagnetic radiation. Reviews of Accelerator Science and Technology: Volume 3: Accelerators as Photon Sources, World Scientific.10.1142/9789814340397_0008 ↗
24. Yokoya, K. (2020, September 18). User Manual of CAIN; Version 2.42; 2011. Available online: https://ilc.kek.jp/~yokoya/CAIN/.
25. CAIN: Conglomérat d’ABEL et d’Interactions Non-linéaires10.1016/0168-9002(94)01186-9 ↗
26. Drebot, I., Bacci, A., Bosotti, A., Broggi, F., Canella, F., Cardarelli, P., Cialdi, S., Faillace, L., Galzerano, G., and Gambaccini, M. (2019). BriXs Ultra High Flux Inverse Compton Source Based on Modified Push-Pull Energy Recovery Linacs. Instruments, 3.10.3390/instruments3030049 ↗
27. Potential of compact Compton sources in the medical field10.1016/j.ejmp.2016.11.003 ↗
28. Labate, L., Tomassini, P., and Gizzi, L.A. (2017). Inverse Compton Scattering X-ray Sources. Handbook of X-ray Imaging: Physics and Technology, CRC Press.10.1201/9781351228251-16 ↗
29. Status of compact inverse Compton sources in Italy: BriXS and STAR
30. Bacci, A., Puppin, E., Agostino, R., Alesini, D., Gatti, G., Petrillo, V., Borgese, G., Anania, M.P., Palmer, D., and Fabris, A. (2014, January 15–20). The STAR project. Proceedings of the 5th International Particle Accelerator Conference (IPAC 2014), Dresden, Germany.
31. The ThomX Project
32. The Munich compact light source: Initial performance measures10.1107/S160057751600967X ↗
33. The versatile X-ray beamline of the Munich Compact Light Source: Design, instrumentation and applications10.1107/S1600577520008309 ↗
34. MariX, an advanced MHz-class repetition rate X-ray source for linear regime time-resolved spectroscopy and photon scattering10.1016/j.nima.2019.03.096 ↗
35. BriXS, a new X-ray inverse Compton source for medical applications10.1016/j.ejmp.2020.08.013 ↗
36. Variola, A., Haissinski, J., Loulergue, A., and Zomer, F. (2020, September 18). THOMX Technical Design Report; 2014. Available online: http://hal.in2p3.fr/in2p3-00971281.
37. Kulpe, S., Dierolf, M., Braig, E., Günther, B., Achterhold, K., Gleich, B., Herzen, J., Rummeny, E., Pfeiffer, F., and Pfeiffer, D. (2018). K-edge subtraction imaging for coronary angiography with a compact synchrotron X-ray source. PLoS ONE, 13.10.1371/journal.pone.0208446 ↗
38. K-edge subtraction imaging for iodine and calcium separation at a compact synchrotron X-ray source10.1117/1.JMI.7.2.023504 ↗
39. Two-colour X-gamma ray inverse Compton back-scattering source10.1209/0295-5075/120/14002 ↗
40. Drebot, I., Calandrino, R., Cardarelli, P., Cialdi, S., Galzerano, G., Gambaccini, M., Giannotti, D., Paternò, G., Petrillo, V., and Serafini, L. (May, January 29). Multi Colour X-Gamma Ray Inverse Compton Back-Scattering Source. Proceedings of the 9th International Particle Accelerator Conference (IPAC’18), Vancouver, BC, Canada.
41. The SPARC_LAB Thomson source10.1016/j.nima.2016.01.089 ↗
42. First results from the Daresbury Compton backscattering X-ray source (COBALD)10.1117/12.859671 ↗
43. Tsinghua Thomson scattering X-ray source10.1016/j.nima.2009.05.088 ↗
44. A trial for fine and low-dose imaging of biological specimens using quasi-monochromatic laser-Compton X-rays10.1016/j.nima.2009.05.157 ↗
45. Tunable, monochromatic X-rays: An enabling technology for molecular/cellular imaging and therapy10.1002/jcb.10632 ↗
46. Brahme, A. (2014). Inverse Compton Scattering Sources. Comprehensive BioMedical Physics, Elsevier.
47. Mono-energy coronary angiography with a compact synchrotron source10.1038/srep42211 ↗
48. MATLAB (2015). Version 8.6 (R2015b), The MathWorks Inc.
49. ICRU (1992). Photon, Electron, Proton and Neutron Interaction Data for Body Tissues, ICRU. Report 46 of the International Commission on Radiation Units and Measurements.
50. Nowotny, R. (2020, September 18). XMuDat: Photon Attenuation Data on PC; 1998. Available online: https://www-nds.iaea.org/publications/iaea-nds/iaea-nds-0195.htm.
51. Comparison of X-ray cross sections for diagnostic and therapeutic medical physics10.1118/1.597899 ↗
52. Analytical description of photon beam phase spaces in inverse Compton scattering sources10.1103/PhysRevAccelBeams.20.080701 ↗
53. Effect of X-ray energy dispersion in digital subtraction imaging at the iodine-edge—A Monte Carlo study10.1118/1.2815360 ↗
54. Inverse Compton radiation: A novel X-ray source for K-edge subtraction angiography?10.1088/1361-6560/ab325c ↗
55. Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: Computer-fit values of Monte Carlo derived data10.1118/1.1472499 ↗
56. Energy and energy spread measurements of an electron beam by Compton scattering method10.1103/PhysRevSTAB.12.062801 ↗
57. Simulation of inverse Compton scattering and its implications on the scattered linewidth10.1103/PhysRevAccelBeams.21.030701 ↗
58. Heck, L., Dierolf, M., Jud, C., Eggl, E., Sellerer, T., Mechlem, K., Günther, B., Achterhold, K., Gleich, B., and Metz, S. (2019). Contrast-enhanced spectral mammography with a compact synchrotron source. PLoS ONE, 14.10.1371/journal.pone.0222816 ↗
59. Quantitative analysis of synchrotron radiation intravenous angiographic images10.1088/0031-9155/50/4/011 ↗
60. Contrast-enhanced digital mammography: Initial clinical experience10.1148/radiol.2283020961 ↗
61. Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging10.1088/0031-9155/52/11/006 ↗
62. Gadolinium-based contrast agents in angiography and interventional radiology10.2214/ajr.173.5.10541129 ↗
63. Safety of gadolinium contrast angiography in patients with chronic renal insufficiency10.1016/S0741-5214(03)00315-X ↗
64. Gadolinium: Nonionic contrast media (1:1) coronary angiography in patients with impaired renal function10.1177/0003319707303640 ↗